低溫等離子滅菌常見問題的原因分析
發(fā)布時間:2018-10-11 12:31
【摘要】:目的分析低溫等離子體滅菌器在醫(yī)院使用過程中的常見問題,并提出相應(yīng)對策,以確保滅菌的成功率。方法加強(qiáng)對操作人員的相關(guān)知識培訓(xùn),組織相關(guān)知識的學(xué)習(xí),分析管腔類器械消毒的注意事宜,注重設(shè)備的保養(yǎng)和維護(hù),分析滅菌監(jiān)測的相關(guān)事宜。結(jié)果工作人員加強(qiáng)相關(guān)知識的學(xué)習(xí)及操作的培訓(xùn)后,能夠正確使用低溫等離子體滅菌器,減少滅菌器操作過程中因操作不當(dāng)而導(dǎo)致的滅菌失敗次數(shù),進(jìn)而提高滅菌成功率;對設(shè)備勤保養(yǎng)也能提高滅菌的成功率。結(jié)論結(jié)合醫(yī)院的實際情況,制定適于醫(yī)院的解決方案,可提高低溫等離子體滅菌器的滅菌成功率,使其發(fā)揮更大的作用。
[Abstract]:Objective to analyze the common problems in the use of low temperature plasma sterilizer in hospital and put forward corresponding countermeasures to ensure the success rate of sterilization. Methods to strengthen the relevant knowledge training of operators, to organize the learning of relevant knowledge, to analyze the matters needing attention in disinfecting the instruments of tube cavity, to pay attention to the maintenance and maintenance of equipment, and to analyze the related matters of sterilization monitoring. Results the staff can use the cryogenic plasma sterilizer correctly after strengthening the relevant knowledge learning and operation training, reduce the frequency of sterilization failure caused by improper operation during the operation of sterilizer, and then improve the success rate of sterilization. Equipment maintenance can also improve the success rate of sterilization. Conclusion according to the actual situation of the hospital, it can improve the success rate of the cryogenic plasma sterilizer and make it play a more important role.
【作者單位】: 海南省婦幼保健院手術(shù)室;
【基金】:海南省自然科學(xué)基金資助項目(309068)
【分類號】:R187
本文編號:2264206
[Abstract]:Objective to analyze the common problems in the use of low temperature plasma sterilizer in hospital and put forward corresponding countermeasures to ensure the success rate of sterilization. Methods to strengthen the relevant knowledge training of operators, to organize the learning of relevant knowledge, to analyze the matters needing attention in disinfecting the instruments of tube cavity, to pay attention to the maintenance and maintenance of equipment, and to analyze the related matters of sterilization monitoring. Results the staff can use the cryogenic plasma sterilizer correctly after strengthening the relevant knowledge learning and operation training, reduce the frequency of sterilization failure caused by improper operation during the operation of sterilizer, and then improve the success rate of sterilization. Equipment maintenance can also improve the success rate of sterilization. Conclusion according to the actual situation of the hospital, it can improve the success rate of the cryogenic plasma sterilizer and make it play a more important role.
【作者單位】: 海南省婦幼保健院手術(shù)室;
【基金】:海南省自然科學(xué)基金資助項目(309068)
【分類號】:R187
【相似文獻(xiàn)】
相關(guān)期刊論文 前1條
1 趙體玉;羅艷霞;王姝;;管腔類器械清洗效果檢測方法的對比研究[J];中華醫(yī)院感染學(xué)雜志;2010年10期
,本文編號:2264206
本文鏈接:http://sikaile.net/yixuelunwen/liuxingb/2264206.html
最近更新
教材專著