ATP生物熒光檢測法對重癥醫(yī)學科環(huán)境清潔質量的干預效果
發(fā)布時間:2019-04-10 19:31
【摘要】:目的了解ATP生物熒光檢測法對重癥醫(yī)學科(ICU)環(huán)境清潔質量的干預效果。方法2013年12月—2014年2月對某院ICU物體表面進行基線檢測,然后采用ATP生物熒光檢測法對ICU物體表面進行檢測并進行干預,評價干預后環(huán)境清潔質量。結果基線調查共采樣627份,合格384份,合格率61.2%,其中床欄頭端、電話按鍵、門把手、電腦鼠標相對光單位(RLU)中位數(shù)300。干預前、中、后ICU物體表面清潔合格率分別為61.2%、76.6%、90.0%(χ~2=142.23,P0.001);干預后ICU工作環(huán)境、主要儀器設備、其他醫(yī)療器具清潔合格率分別為85.5%、98.3%、92.6%,均高于干預前(分別為48.8%、84.4%、69.1%)(均P0.05)。結論 ATP生物熒光法能簡便、快捷的檢測消毒效果,有助于ICU及時有效地干預,提高環(huán)境清潔合格率。
[Abstract]:Objective to investigate the effect of ATP bioluminescence detection on environmental cleaning quality of (ICU) in severe medical sciences. Methods from December 2013 to February 2014, the surface of ICU object in a hospital was detected by baseline, then the surface of ICU object was detected by ATP bioluminescence detection method and intervened to evaluate the clean quality of the environment after intervention. Results A total of 627 samples were collected from baseline survey, 384 of which were qualified, and the qualified rate was 61.2%. The median (RLU) of bedbar, telephone button, door handle and computer mouse relative to light unit was 300. 3%. Before and after intervention, the eligible rates of ICU surface cleaning were 61.2%, 76.6% and 90.0% respectively (蠂 ~ 2 / 142.23, P0.001). After intervention, the qualified rates of ICU working environment, main equipment and other medical devices were 85.5%, 98.3% and 92.6% respectively, which were higher than those before intervention (48.8%, 84.4%, 69.1% respectively) (all P0.05). Conclusion ATP bioluminescence method can detect the disinfection effect easily and quickly. It is helpful for ICU to intervene in time and improve the qualified rate of environmental cleaning.
【作者單位】: 河南中醫(yī)藥大學第一附屬醫(yī)院;國家衛(wèi)生計生委衛(wèi)生發(fā)展研究中心;
【基金】:河南省中醫(yī)藥科學研究專項課題(2013ZY02049)
【分類號】:R197.32;R459.7
本文編號:2456062
[Abstract]:Objective to investigate the effect of ATP bioluminescence detection on environmental cleaning quality of (ICU) in severe medical sciences. Methods from December 2013 to February 2014, the surface of ICU object in a hospital was detected by baseline, then the surface of ICU object was detected by ATP bioluminescence detection method and intervened to evaluate the clean quality of the environment after intervention. Results A total of 627 samples were collected from baseline survey, 384 of which were qualified, and the qualified rate was 61.2%. The median (RLU) of bedbar, telephone button, door handle and computer mouse relative to light unit was 300. 3%. Before and after intervention, the eligible rates of ICU surface cleaning were 61.2%, 76.6% and 90.0% respectively (蠂 ~ 2 / 142.23, P0.001). After intervention, the qualified rates of ICU working environment, main equipment and other medical devices were 85.5%, 98.3% and 92.6% respectively, which were higher than those before intervention (48.8%, 84.4%, 69.1% respectively) (all P0.05). Conclusion ATP bioluminescence method can detect the disinfection effect easily and quickly. It is helpful for ICU to intervene in time and improve the qualified rate of environmental cleaning.
【作者單位】: 河南中醫(yī)藥大學第一附屬醫(yī)院;國家衛(wèi)生計生委衛(wèi)生發(fā)展研究中心;
【基金】:河南省中醫(yī)藥科學研究專項課題(2013ZY02049)
【分類號】:R197.32;R459.7
【相似文獻】
相關期刊論文 前6條
1 陳凌梅;李煒如;;地塞米松及葡萄糖對缺血缺氧性腦損傷新生大鼠血糖和腦ATP生成率及ATP酶分解活性的影響[J];中華婦幼臨床醫(yī)學雜志;2007年03期
2 王成鋒;趙平;張偉;張建偉;;ATP生物熒光腫瘤藥敏檢測技術在胰腺癌中的應用[J];中國微創(chuàng)外科雜志;2007年11期
3 羅永富;脂肪酸體內氧化ATP生成數(shù)量計算公式[J];醫(yī)藥世界;2005年07期
4 羅永富;;脂肪酸體內氧化ATP生成數(shù)量計算公式[J];衛(wèi)生職業(yè)教育;2006年06期
5 張浩;金欽文;陳建思;;胃癌組織ATP生物熒光腫瘤體外藥物敏感試驗[J];中國癌癥防治雜志;2011年01期
6 ;[J];;年期
相關會議論文 前1條
1 馮敏;朱佳廷;劉春泉;;ATP生物發(fā)光技術在農產(chǎn)品輻照滅菌中的應用研究[A];第五屆核農學青年科技工作者學術交流會論文集[C];2006年