白內(nèi)障患者眼生物學(xué)參數(shù)分布特征及變化趨勢
發(fā)布時(shí)間:2019-05-01 06:03
【摘要】:目的探討中老年白內(nèi)障患者眼生物學(xué)參數(shù)分布狀況及變化規(guī)律。方法選取2012年7月至2013年7月于我院住院手術(shù)治療的40歲以上白內(nèi)障患者1861例,應(yīng)用IOL Master測量儀測量眼軸(axial length,AL)、前房深度(anterior chamber depth,ACD),對(duì)結(jié)果進(jìn)行統(tǒng)計(jì)分析。結(jié)果 1861例白內(nèi)障患者AL均值為23.19 mm(95%可信區(qū)間為23.15~23.23 mm),ACD均值為3.14 mm(95%可信區(qū)間為3.12~3.16 mm),男性AL、ACD均大于女性,差異均有統(tǒng)計(jì)學(xué)意義(均為P0.05);AL、ACD隨著年齡的增長而減小或變淺(均為P0.001)。結(jié)論 AL、ACD隨著年齡的增長而遞減,應(yīng)用IOL-Master測量儀測量白內(nèi)障患者的眼生物學(xué)參數(shù)結(jié)果可以反映正常人群的眼解剖參數(shù)參考范圍及變化趨勢。
[Abstract]:Objective to investigate the distribution and changes of ocular biological parameters in middle-aged and elderly cataract patients. Methods from July 2012 to July 2013, 1861 cataract patients over 40 years old were treated in our hospital. The eye axis (axial length,AL) and anterior chamber depth (anterior chamber depth,ACD) were measured by IOL Master. The results were analyzed statistically. Results the mean AL of 1861 cataract patients was 23.19 mm (95% confidence interval 23.15 and 23.23 mm), ACD mean 3.14 mm) (95% confidence interval 3.12 mm), 3.16 mm), male AL,ACD was higher than that of female). The difference was statistically significant (all P0.05); AL,ACD decreased or shrunk with age (P0.001). Conclusion AL,ACD decreases with age. The results of eye biological parameters measured by IOL-Master instrument can reflect the reference range and changing trend of ocular anatomical parameters in normal population. [WT5HZ] [WT5 "HZ] conclusion [WT5" BZ]
【作者單位】: 蘭州大學(xué)第二醫(yī)院眼科;
【分類號(hào)】:R776.1
[Abstract]:Objective to investigate the distribution and changes of ocular biological parameters in middle-aged and elderly cataract patients. Methods from July 2012 to July 2013, 1861 cataract patients over 40 years old were treated in our hospital. The eye axis (axial length,AL) and anterior chamber depth (anterior chamber depth,ACD) were measured by IOL Master. The results were analyzed statistically. Results the mean AL of 1861 cataract patients was 23.19 mm (95% confidence interval 23.15 and 23.23 mm), ACD mean 3.14 mm) (95% confidence interval 3.12 mm), 3.16 mm), male AL,ACD was higher than that of female). The difference was statistically significant (all P0.05); AL,ACD decreased or shrunk with age (P0.001). Conclusion AL,ACD decreases with age. The results of eye biological parameters measured by IOL-Master instrument can reflect the reference range and changing trend of ocular anatomical parameters in normal population. [WT5HZ] [WT5 "HZ] conclusion [WT5" BZ]
【作者單位】: 蘭州大學(xué)第二醫(yī)院眼科;
【分類號(hào)】:R776.1
【共引文獻(xiàn)】
相關(guān)期刊論文 前10條
1 王崢;鄭帆;吳文凌;葉向_g;;Lenstar LS900、IOLMaster與A超測量白內(nèi)障患者人工晶狀體度數(shù)的對(duì)比研究[J];福建醫(yī)藥雜志;2012年01期
2 柏全豪;王君麗;王慶強(qiáng);閻啟昌;張勁松;;IOLMaster與接觸式A超測量前房深度和眼軸長度的比較研究(英文)[J];國際眼科雜志;2007年04期
3 丁曉霞;張勁松;;無晶狀體眼患兒的眼軸測量方法[J];國際眼科雜志;2008年12期
4 方薇;張健;;國人正常眼軸老年白內(nèi)障患者人工晶狀體屈光度計(jì)算公式的準(zhǔn)確性研究[J];國際眼科雜志;2009年04期
5 李,
本文編號(hào):2469045
本文鏈接:http://sikaile.net/yixuelunwen/yank/2469045.html
最近更新
教材專著