B-D測(cè)試專(zhuān)用架的設(shè)計(jì)與應(yīng)用
發(fā)布時(shí)間:2018-07-28 10:56
【摘要】:正《醫(yī)院消毒供應(yīng)中心管理規(guī)范》之清洗消毒及滅菌效果監(jiān)測(cè)標(biāo)準(zhǔn)(WS310.3-2009)中指出:預(yù)真空壓力蒸汽滅菌器(包括脈動(dòng)真空)應(yīng)在每天開(kāi)始滅菌前進(jìn)行B-D測(cè)試,B-D測(cè)試合格后,滅菌器方可使用。常規(guī)B-D測(cè)試是在滅菌柜選預(yù)熱后空載狀態(tài)下只將B-D試驗(yàn)包置于滅菌柜內(nèi)滅菌車(chē)的前底層,靠近柜門(mén)與排氣口底前方〔1〕處再運(yùn)行BD程序,B-D程序結(jié)束后B-D測(cè)試合格,證實(shí)滅
[Abstract]:The Standard for Monitoring the cleaning, Disinfection and Sterilization effect (WS310.3-2009) of the Hospital Disinfection supply Center, points out that the pre-vacuum pressure steam sterilizer (including pulsating vacuum) should be tested by B-D before it begins to sterilize every day. Sterilizer can only be used. The routine B-D test is to put the B-D test kit in the front and bottom of the sterilizer only under the condition of no load after the sterilization cabinet is preheated, and then run the BD program (1) near the front of the cabinet door and the bottom of the vent to pass the B-D test after the completion of the B-D program. It is proved that the test kit is extinguished.
【作者單位】: 浠水縣人民醫(yī)院;
【分類(lèi)號(hào)】:R187
本文編號(hào):2149886
[Abstract]:The Standard for Monitoring the cleaning, Disinfection and Sterilization effect (WS310.3-2009) of the Hospital Disinfection supply Center, points out that the pre-vacuum pressure steam sterilizer (including pulsating vacuum) should be tested by B-D before it begins to sterilize every day. Sterilizer can only be used. The routine B-D test is to put the B-D test kit in the front and bottom of the sterilizer only under the condition of no load after the sterilization cabinet is preheated, and then run the BD program (1) near the front of the cabinet door and the bottom of the vent to pass the B-D test after the completion of the B-D program. It is proved that the test kit is extinguished.
【作者單位】: 浠水縣人民醫(yī)院;
【分類(lèi)號(hào)】:R187
【相似文獻(xiàn)】
相關(guān)期刊論文 前7條
1 王蓬;滕智英;;B-D測(cè)試的相關(guān)影響因素觀察[J];中國(guó)消毒學(xué)雜志;2007年01期
2 李淑君;包金英;方亮;陳志玲;;B-D測(cè)試在消毒供應(yīng)中心的應(yīng)用及影響因素[J];齊齊哈爾醫(yī)學(xué)院學(xué)報(bào);2010年21期
3 張芳;楊立霞;秦安華;王菡;;兩種B-D包試驗(yàn)不合格原因分析及對(duì)策[J];中華醫(yī)院感染學(xué)雜志;2010年20期
4 劉禮霞;王軼;;兩種B-D測(cè)試包的監(jiān)測(cè)效果比較[J];中華醫(yī)院感染學(xué)雜志;2009年20期
5 余正香;;環(huán)境溫度和預(yù)熱時(shí)間對(duì)B-D測(cè)試的影響[J];中國(guó)感染控制雜志;2006年03期
6 歐少青;王志亮;葉玉珍;何鳳貞;;一次性B-D包產(chǎn)品質(zhì)量對(duì)B-D測(cè)試結(jié)果的影響[J];中國(guó)消毒學(xué)雜志;2010年04期
7 李娟;;B-D測(cè)試不合格原因分析及解決辦法[J];醫(yī)療衛(wèi)生裝備;2010年01期
,本文編號(hào):2149886
本文鏈接:http://sikaile.net/yixuelunwen/liuxingb/2149886.html