全自動內(nèi)鏡清洗消毒機(jī)消毒纖維支氣管鏡失敗原因分析
[Abstract]:Objective to analyze the causes of failure in disinfection of fiberoptic bronchoscope cleaning and disinfecting machine, and to put forward corresponding improvement measures to optimize the disinfection efficacy of automatic endoscope cleaning and disinfection machine. Methods Endoscopic endoscopes were sampled according to the national standard in 2013-2014. Seven positive specimens were identified by bacteriology. The reasons of failure were found from four aspects: endoscope pretreatment, equipment maintenance management, disinfectant management and personnel training. Training, standard process development, equipment cleaning and maintenance and other aspects of targeted improvement measures. Results through root cause analysis, it was found that the main reasons were that the personnel training was not in place, the operators were too dependent on the equipment, the effective pre-cleaning was not carried out, and the automatic cleaning and disinfecting machine itself was not in place. No standardized operation and maintenance process has been established, through the establishment of endoscopic first wash responsibility system, equipment preventive maintenance plan, standardized operation and management process, strengthen the personnel training of 4 improvement measures to carry out targeted management, the establishment of the first wash responsibility system, equipment preventive maintenance plan, standardized operation and management process, The qualified rate of sampling in the later stage of fiberoptic endoscopy cleaning and disinfection was up to standard. Conclusion Pretreatment, maintenance of equipment, training of personnel and establishment of standardized flow should be strengthened in the operation of automatic endoscopic cleaning and disinfecting machine in order to ensure the efficacy of cleaning and disinfection.
【作者單位】: 蘇北人民醫(yī)院消毒供應(yīng)中心;蘇北人民醫(yī)院內(nèi)鏡中心;蘇北人民醫(yī)院臨床檢驗(yàn)中心;蘇北人民醫(yī)院耳鼻咽喉科;
【基金】:江蘇省自然科學(xué)基金資助項(xiàng)目(BK20131233)
【分類號】:R187.4
【共引文獻(xiàn)】
相關(guān)期刊論文 前2條
1 陳新燕;王昌雄;陳光蘭;何延軍;劉巧影;;內(nèi)鏡清洗消毒方式:手工處理和全自動機(jī)器處理比較研究[J];中國中西醫(yī)結(jié)合消化雜志;2014年04期
2 Günter Kampf;Patricia M Fliss;Heike Martiny;;Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?[J];World Journal of Gastrointestinal Endoscopy;2014年09期
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 何夕昆;盛娟;吳麗娟;左贊;;全自動內(nèi)鏡清洗消毒機(jī)的臨床應(yīng)用及效果觀察[J];中國內(nèi)鏡雜志;2008年06期
2 彭湘粵;夏元喜;胡賽紅;劉朝輝;王萍;;全自動內(nèi)鏡清洗消毒機(jī)在纖維喉鏡消毒中的應(yīng)用[J];當(dāng)代護(hù)士(?瓢);2010年10期
3 劉華敏;徐娟;劉曉玉;劉玲;;全自動內(nèi)鏡清洗消毒機(jī)與一體化內(nèi)鏡清洗工作站消毒效果的比較[J];當(dāng)代護(hù)士(中旬刊);2014年01期
4 邵愛仙,曹梅娟,方英,虞朝輝,厲有名;內(nèi)鏡清洗消毒機(jī)去除胃鏡污染乙肝病毒的研究[J];護(hù)理與康復(fù);2002年01期
5 馬彩虹;譚玉娥;馬瑩;;全自動內(nèi)鏡清洗消毒機(jī)臨床應(yīng)用體會[J];延安大學(xué)學(xué)報(bào)(醫(yī)學(xué)科學(xué)版);2008年03期
6 王玉敏;;集成內(nèi)鏡洗消工作站與全自動洗消機(jī)互補(bǔ)性研究[J];當(dāng)代護(hù)士(中旬刊);2014年04期
7 ;衛(wèi)生部關(guān)于印發(fā)《內(nèi)鏡清洗消毒機(jī)消毒效果檢驗(yàn)技術(shù)規(guī)范(試行)》的通知[J];中華人民共和國衛(wèi)生部公報(bào);2004年01期
8 劉萱,于中麟,王惠吉,許淑珍,張澍田;消化內(nèi)鏡清洗消毒機(jī)現(xiàn)場試驗(yàn)初步研究[J];中國內(nèi)鏡雜志;2004年10期
9 陳朝霞;段進(jìn)糧;文燕;黃妙娟;俞紅華;;全自動內(nèi)鏡清洗在消毒機(jī)清洗消毒消化內(nèi)鏡中的應(yīng)用[J];護(hù)理實(shí)踐與研究;2010年19期
10 王玉敏;;DSD-201全自動內(nèi)鏡洗消機(jī)的臨床應(yīng)用[J];當(dāng)代護(hù)士(中旬刊);2014年02期
相關(guān)重要報(bào)紙文章 前1條
1 周乙龍;內(nèi)鏡清洗消毒機(jī)消毒效果檢驗(yàn)技術(shù)[N];中國中醫(yī)藥報(bào);2003年
相關(guān)碩士學(xué)位論文 前2條
1 楊海軼;《內(nèi)鏡清洗消毒技術(shù)規(guī)范(2004年版)》執(zhí)行中存在的主要問題與解決對策初步研究[D];南方醫(yī)科大學(xué);2007年
2 曹梅娟;內(nèi)鏡清洗消毒機(jī)去除胃鏡污染乙肝病毒的研究[D];浙江大學(xué);2002年
,本文編號:2138472
本文鏈接:http://sikaile.net/yixuelunwen/liuxingb/2138472.html