線圈隔熱層對光纖陀螺溫度誤差的影響分析
發(fā)布時間:2018-04-24 11:41
本文選題:光纖陀螺 + 光纖線圈 ; 參考:《中國慣性技術(shù)學(xué)報(bào)》2017年03期
【摘要】:針對溫度變化所引起的光纖陀螺非互易相移誤差,詳細(xì)研究了隔熱材料對減小熱漂移誤差的作用,并詳細(xì)比較了使用不同厚度隔熱層的光纖陀螺在相同變溫歷程下的熱漂移誤差大小以及達(dá)到熱平衡狀態(tài)所需的時間。仿真結(jié)果表明,當(dāng)隔熱層的厚度由0mm變化到4mm的過程中,熱漂移誤差的峰值由0.12(°)/h降低到了0.08(°)/h,同時達(dá)到熱平衡的時間從2 520 s增加到了3 600 s。利用該仿真結(jié)果,可以在保證熱啟動時間滿足條件的前提下找到一個最優(yōu)的隔熱層厚度,從而使熱漂移誤差的峰值最小。
[Abstract]:In view of the non reciprocal phase shift error of fiber optic gyroscope caused by temperature change, the effect of heat insulation material on reducing the heat drift error is studied in detail, and the heat drift error and the time needed to reach the state of heat balance are compared in detail. In the process of the thickness of the heat insulation from 0mm to 4mm, the peak value of the thermal drift error is reduced from 0.12 (degree) /h to 0.08 () /h, and the time of heat balance is increased from 2520 s to 3600 S. to use the simulation results. The peak of the shift error is the smallest.
【作者單位】: 北京理工大學(xué)自動化學(xué)院;北京自動化控制設(shè)備研究所;
【基金】:國家高技術(shù)研究發(fā)展計(jì)劃(863計(jì)劃)(2006AA12Z319)
【分類號】:TN253;TN96
【參考文獻(xiàn)】
相關(guān)期刊論文 前5條
1 李緒友;張春梅;劉華兵;凌衛(wèi)偉;魏延輝;;光纖環(huán)十六極對稱繞法溫度性能的仿真與分析[J];中國慣性技術(shù)學(xué)報(bào);2016年06期
2 張忠厚;王銀濤;楊光;馮麗;閆春綿;;復(fù)合阻燃劑阻燃硬質(zhì)聚氨酯泡沫塑料的性能研究[J];工程塑料應(yīng)用;2014年01期
3 糜婧;謝松明;杜建新;郝建薇;;含磷阻燃劑對硬質(zhì)聚氨酯泡沫塑料阻燃性能和力學(xué)性能的影響[J];高分子材料科學(xué)與工程;2013年10期
4 王巍;向政;邢輝;;光纖陀螺光纖敏感線圈三維溫度瞬態(tài)響應(yīng)模型[J];中國慣性技術(shù)學(xué)報(bào);2012年05期
5 王sピ,
本文編號:1796476
本文鏈接:http://sikaile.net/kejilunwen/xinxigongchenglunwen/1796476.html
最近更新
教材專著