變阻抗傳輸線能量傳輸效率分析
發(fā)布時間:2018-04-17 20:10
本文選題:變阻抗傳輸線 + 能量傳輸效率。 參考:《強激光與粒子束》2017年06期
【摘要】:采用數(shù)值方法分析了阻抗各向同性、波速不變的變阻抗傳輸線(指數(shù)型、雙曲型和線性型)的電壓反射系數(shù),得到了能量傳輸效率與歸一化頻率、阻抗變比之間的關(guān)系。結(jié)果表明,在低頻條件下(歸一化頻率小于2),指數(shù)傳輸線的能量傳輸效率最高。計算了Z300裝置變阻抗傳輸線的能量傳輸線效率,指數(shù)線為91.6%、雙曲線為90.4%,圓錐線為91.2%。
[Abstract]:The voltage reflection coefficients of variable-impedance transmission lines (exponential, hyperbolic and linear) with isotropic impedance and constant wave velocity are analyzed numerically. The relationship between energy transmission efficiency and normalized frequency and impedance ratio is obtained.The results show that the energy transmission efficiency of exponential transmission line is the highest at low frequency (normalized frequency less than 2).The energy transmission line efficiency of variable impedance transmission line in Z300 device is calculated. The exponential line is 91.6, the hyperbolic line is 90.4, and the cone line is 91.2.
【作者單位】: 中國工程物理研究院流體物理研究所中國工程物理研究院脈沖功率科學與技術(shù)重點實驗室;
【分類號】:TN811