一款小角X射線散射原位測量專用簡易樣品加熱裝置
發(fā)布時間:2019-01-09 14:10
【摘要】:原位加熱實驗是同步輻射小角X射線散射領域的新熱點。本文針對同步輻射小角X射線散射中需要加熱并原位實時檢測的實驗而設計的一款樣品簡易原位加熱專用裝置,該裝置主要由溫控器、樣品池、固定架組成,它具有結構簡單、操作容易的特點。本文介紹該裝置的基本結構、特點并采用該裝置進行原位加熱干燥褐煤實驗,通過分析實驗結果驗證裝置的可行性。
[Abstract]:In-situ heating experiment is a new hotspot in the field of small angle synchrotron radiation X-ray scattering. In this paper, a simple in situ heating device for synchrotron radiation in small angle X-ray scattering is designed. The device is mainly composed of a thermostat, a sample pool and a fixed frame. It has a simple structure. Features of ease of operation. In this paper, the basic structure and characteristics of the device are introduced, and the feasibility of the device is verified by analyzing the experimental results of in-situ heating and drying of lignite.
【作者單位】: 安徽大學;北京同步輻射裝置中國科學院高能物理研究所;
【基金】:研究生學術創(chuàng)新項目研究(yqh100207) 國家自然科學基金(U1332107、U1532105) 中國礦業(yè)大學(北京)煤炭資源與安全開采國家重點實驗室開放課題(SKLCRSM14KFA02)
【分類號】:O434.1
[Abstract]:In-situ heating experiment is a new hotspot in the field of small angle synchrotron radiation X-ray scattering. In this paper, a simple in situ heating device for synchrotron radiation in small angle X-ray scattering is designed. The device is mainly composed of a thermostat, a sample pool and a fixed frame. It has a simple structure. Features of ease of operation. In this paper, the basic structure and characteristics of the device are introduced, and the feasibility of the device is verified by analyzing the experimental results of in-situ heating and drying of lignite.
【作者單位】: 安徽大學;北京同步輻射裝置中國科學院高能物理研究所;
【基金】:研究生學術創(chuàng)新項目研究(yqh100207) 國家自然科學基金(U1332107、U1532105) 中國礦業(yè)大學(北京)煤炭資源與安全開采國家重點實驗室開放課題(SKLCRSM14KFA02)
【分類號】:O434.1
【相似文獻】
相關期刊論文 前10條
1 羅太昭,周達君,李先樞,蔡茂略;密封式激光喇曼散射樣品池[J];激光;1982年02期
2 張增福;李晨曦;陳文亮;趙會娟;徐可欣;;適合逃逸氨取樣測量的新型樣品池研究[J];激光與紅外;2014年05期
3 朱瑞濱;劉偉龍;宋云飛;王偉;張福長;羅利軍;王文田;賈培起;劉曉e,