上海市醫(yī)療機(jī)構(gòu)口腔綜合治療臺(tái)水污染情況調(diào)查
[Abstract]:Objective to understand the water pollution situation of oral comprehensive treatment table in medical institutions, analyze the causes of pollution, and provide evidence for effective intervention measures. Methods the treatment water of 187 medical institutions in Shanghai was detected by on-the-spot inspection and sampling. Results A total of 6 168 water samples were collected from the department of stomatology in all levels of medical institutions. The average qualified rate of hygienic quality was 62.89%. The eligible rates of first, second and third level hospitals were 59.95%, 68.79% and 50.23% respectively, and 64.57% of basic oral clinics. The qualified rates of source water, pipeline water, mouthwash, rinse water and mobile phone outlet water were 84.21%, 83.42%, 67.24%, 65.75% and 52.97%, respectively. The qualified rate of water storage tank water was 57.05%. Among the five water sources, the sanitary quality of aseptic water supply system is the worst, and the qualified rate is only 34.78%. Conclusion the water pollution in the comprehensive treatment table of Shanghai Stomatological Medical Institution is serious, and the qualified rate of hygienic quality of the treatment water in the stomatology department of the third grade hospital is the lowest among different types of hospitals. It is suggested that the standard should be formulated for the management of water cleaning and disinfection in the oral department.
【作者單位】: 上海市疾病預(yù)防控制中心;上海市奉賢區(qū)疾病預(yù)防控制中心;
【分類號(hào)】:R187
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 邢軍;劉旭;李麗;;口腔綜合治療臺(tái)水路的清潔與消毒[J];中華醫(yī)院感染學(xué)雜志;2007年08期
2 朱笠;梁玉紅;鄒梅;;醫(yī)院口腔綜合治療臺(tái)診療用水污染狀況調(diào)查[J];中國(guó)消毒學(xué)雜志;2008年01期
3 劉德豐;王斌;劉慶華;汪洋;朱軍生;彭燕瓊;王獻(xiàn)麗;;口腔科綜合治療臺(tái)供水系統(tǒng)消毒方法[J];中國(guó)消毒學(xué)雜志;2009年06期
4 余青嬋;蔡永紅;;開展QC活動(dòng) 完善口腔綜合治療臺(tái)管道消毒[J];家庭護(hù)士;2008年01期
5 王平;張松志;樊春卉;宋瑾;郝文華;;耳鼻喉科綜合治療臺(tái)噴槍頭污染與消毒觀察[J];新鄉(xiāng)醫(yī)學(xué)院學(xué)報(bào);2011年05期
6 鄧偉江;石鳳群;林德健;何曙光;;口腔科牙椅儲(chǔ)水瓶消毒效果監(jiān)測(cè)[J];中國(guó)校醫(yī);2009年05期
7 李震,宋文斯;口腔科交叉感染的危險(xiǎn)性分析與控制[J];湖北預(yù)防醫(yī)學(xué)雜志;2003年01期
8 許建華;陳貴敏;;口腔門診危險(xiǎn)因素與控制[J];東南國(guó)防醫(yī)藥;2008年03期
9 楊鳳珍,陳肖芳,蔡樹英;口腔?圃簝(nèi)感染各環(huán)節(jié)的控制和管理[J];現(xiàn)代護(hù)理;2002年02期
10 劉曉杰;黃新宇;王艷秋;孫利群;姜曉春;李靜;;口腔器械污染狀況及消毒方法的應(yīng)用[J];中國(guó)消毒學(xué)雜志;2007年02期
相關(guān)會(huì)議論文 前9條
1 武梅;;ESTETICA E80口腔綜合治療臺(tái)的消毒與保養(yǎng)的重要性[A];中華護(hù)理學(xué)會(huì)2009全國(guó)口腔科護(hù)理學(xué)術(shù)交流暨專題講座會(huì)議論文匯編[C];2009年
2 方秀娟;錢敏;石勝陵;;口腔綜合治療臺(tái)交叉感染相關(guān)因素分析及措施[A];全國(guó)口腔科護(hù)理學(xué)術(shù)交流暨專題講座會(huì)議論文匯編[C];2008年
3 張富玉;趙薇;;臭氧對(duì)口腔綜合臺(tái)水系統(tǒng)消毒的應(yīng)用[A];中華醫(yī)院管理學(xué)會(huì)第十二屆全國(guó)醫(yī)院感染管理學(xué)術(shù)年會(huì)論文匯編[C];2005年
4 王斌;朱軍生;張臘梅;劉小泉;孟凡振;劉德豐;;武漢市口腔診療機(jī)構(gòu)綜合治療臺(tái)供水管路污染狀況調(diào)查[A];湖北省暨武漢市微生物學(xué)會(huì)分析微生物專業(yè)委員會(huì)第十屆第五次學(xué)術(shù)會(huì)議論文匯編[C];2008年
5 曹力燕;;口腔診療中導(dǎo)致交叉感染的因素與持續(xù)改進(jìn)措施[A];全國(guó)醫(yī)院感染護(hù)理學(xué)術(shù)交流暨專題講座會(huì)議論文匯編[C];2008年
6 路海云;許志紅;桂和明;;常用口腔機(jī)頭消毒方法的效果評(píng)價(jià)[A];全國(guó)第六屆口腔醫(yī)院管理研討會(huì)論文匯編[C];2000年
7 李維弟;郭瑩;陳世璋;;口腔現(xiàn)代消毒隔離體系的發(fā)展趨勢(shì)[A];中華護(hù)理學(xué)會(huì)2009全國(guó)口腔科護(hù)理學(xué)術(shù)交流暨專題講座會(huì)議論文匯編[C];2009年
8 童璐;;口腔診療中交叉感染的控制[A];全國(guó)口腔護(hù)理新進(jìn)展研討會(huì)論文匯編[C];2011年
9 吳雅成;;口腔診療的規(guī)范消毒與感染控制[A];全國(guó)口腔護(hù)理新進(jìn)展研討會(huì)論文匯編[C];2011年
相關(guān)碩士學(xué)位論文 前1條
1 楊鑫;臭氧對(duì)口腔綜合治療臺(tái)水道系統(tǒng)中HBV滅活效果的實(shí)驗(yàn)研究[D];天津醫(yī)科大學(xué);2012年
,本文編號(hào):2453450
本文鏈接:http://sikaile.net/yixuelunwen/liuxingb/2453450.html