體表電極代替多導(dǎo)食道電極測(cè)定慢性阻塞性肺疾病患者呼吸中樞驅(qū)動(dòng)的可行性
本文選題:呼吸中樞驅(qū)動(dòng) + 等二氧化碳高通氣 ; 參考:《實(shí)用醫(yī)學(xué)雜志》2017年15期
【摘要】:目的探討體表電極代替多導(dǎo)食道電極測(cè)定慢性阻塞性肺疾病(慢阻肺)患者呼吸中樞驅(qū)動(dòng)的可行性。方法研究對(duì)象為呼吸科門診29例穩(wěn)定期中重度慢阻肺患者,均為男性,平均年齡(65.6±7.2)歲。采用體表電極和多導(dǎo)食道電極同時(shí)記錄患者吸入支氣管舒張劑前后靜息狀態(tài)和等二氧化碳高通氣(MIV)時(shí)膈肌肌電和肺通氣量的變化,比較兩種方法測(cè)定的呼吸中樞驅(qū)動(dòng)的差異。采用重復(fù)測(cè)量數(shù)據(jù)的方差分析,兩兩比較用最小LSD檢驗(yàn),相關(guān)分析采用Pearson檢驗(yàn)。結(jié)果吸入支氣管舒張劑后,患者靜息和MIV時(shí)的肺通氣量增加,體表電極和多導(dǎo)食道電極測(cè)定的呼吸中樞驅(qū)動(dòng)均同步降低,呈顯著相關(guān)(r=0.660,P0.01)。結(jié)論采取措施盡可能減少體表電極干擾的情況下,體表電極可以代替多導(dǎo)食道電極測(cè)定慢阻肺患者的呼吸中樞驅(qū)動(dòng)。
[Abstract]:Objective to study the feasibility of using body surface electrode instead of multichannel esophageal electrode to measure respiratory center drive in patients with chronic obstructive pulmonary disease (COPD). Methods A total of 29 moderate and severe COPD patients (mean age: 65.6 鹵7.2) years were enrolled in this study. The changes of diaphragm electromyography and pulmonary ventilation volume during inhalation of bronchodiastolic agents and iso-carbon dioxide hyperventilation (MIV) were recorded by body surface electrode and multichannel electrode simultaneously. The difference of respiratory center drive between the two methods was compared. The variance analysis of repeated measurement data, the minimum LSD test for pairwise comparison, and Pearson test for correlation analysis were used. Results after inhaling bronchodiastolic agent, the pulmonary ventilation volume increased at rest and MIV, and the respiratory center drive measured by body surface electrode and multichannel esophagus electrode decreased synchronously, and there was a significant correlation between the lung ventilation volume and the respiratory center drive measured by body surface electrode and multichannel esophagus electrode. Conclusion when some measures are taken to minimize the interference of body surface electrodes, body surface electrodes can replace multichannel esophageal electrodes to determine the respiratory center drive in patients with chronic obstructive pulmonary disease.
【作者單位】: 廣州市番禺區(qū)中心醫(yī)院呼吸內(nèi)科;南方醫(yī)科大學(xué)珠江醫(yī)院呼吸內(nèi)科;廣州醫(yī)科大學(xué)附屬第一醫(yī)院呼吸內(nèi)科;
【基金】:廣州市科技攻關(guān)專項(xiàng)基金資助(編號(hào):201300000171) 廣東省科技計(jì)劃項(xiàng)目(編號(hào):粵科[2013]137)
【分類號(hào)】:R563.9
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 萬桂敏,張麗虹;用平板氟電極測(cè)定微量血清氟[J];中國(guó)地方病防治雜志;1990年06期
2 張安靖;氟電極測(cè)定茶葉中氟的質(zhì)量?jī)?nèi)控實(shí)驗(yàn)[J];預(yù)防醫(yī)學(xué)情報(bào)雜志;2003年06期
3 陸桂祥;;用氨選擇性電極測(cè)定尿(血)中尿素及氨[J];國(guó)外醫(yī)學(xué).臨床生物化學(xué)與檢驗(yàn)學(xué)分冊(cè);1982年01期
4 徐鳳儀;碘離子選擇電極測(cè)定食鹽中的碘[J];中國(guó)地方病學(xué)雜志;1984年01期
5 白文林;胡守珍;;銀離子電極測(cè)定水中微量氰[J];鐵道勞動(dòng)衛(wèi)生通訊;1984年02期
6 彭應(yīng)馥;用硫離子電極測(cè)定水及廢水中硫化物[J];環(huán)境與健康雜志;1987年01期
7 蔣復(fù);馬一平;;氯離子選擇電極測(cè)定輸液中氯化鈉的含量[J];化學(xué)傳感器;1985年01期
8 余月仙;氰離子選擇電極測(cè)定酒中氰化物[J];浙江預(yù)防醫(yī)學(xué);1999年02期
9 陳執(zhí)中;胥保生;姜超;;塑料膜電極在藥物分析中的應(yīng)用[J];中成藥研究;1981年07期
10 廖麗華;;銀離子電極測(cè)定苯妥英鈉含量[J];化學(xué)傳感器;1989年01期
相關(guān)會(huì)議論文 前2條
1 舒菲菲;賈金平;;化學(xué)滴液電極測(cè)定水中的pH值[A];第五屆全國(guó)環(huán)境化學(xué)大會(huì)摘要集[C];2009年
2 王s,
本文編號(hào):2024096