管式爐加熱-紅外吸收法測定鈾金屬中碳
發(fā)布時間:2018-10-08 15:06
【摘要】:稱取100mg處理后試樣,選取加熱溫度為850℃,建立了管式爐加熱紅外吸收法測定鈾金屬中微量碳的方法。試驗表明:將金屬鈾切屑試樣用硝酸(1+1)加熱至微沸并保持2min,取出后再依次用水、丙酮、無水乙醇漂洗可有效去除金屬鈾切屑樣品表面的碳沾污。以蔗糖作為校準(zhǔn)標(biāo)樣,碳量在0~12.5μg之間線性相關(guān)系數(shù)(r)為0.999 8。方法空白值為2.4μg/g,測定下限為5μg/g。按照實驗方法對鈾金屬材料中碳進行測定,結(jié)果的相對標(biāo)準(zhǔn)偏差(RSD,n=3)為4.3%~6.1%,加標(biāo)回收率為100%。應(yīng)用于鈾金屬材料中碳含量的測定,結(jié)果與高頻燃燒-紅外吸收法一致。
[Abstract]:A method for the determination of trace carbon in uranium metal by tube furnace heating infrared absorption method was established by using 100mg treatment sample and heating temperature of 850 鈩,
本文編號:2257221
[Abstract]:A method for the determination of trace carbon in uranium metal by tube furnace heating infrared absorption method was established by using 100mg treatment sample and heating temperature of 850 鈩,