氯氣校正法測(cè)定垃圾填埋場(chǎng)滲濾液高氯納濾出水COD
發(fā)布時(shí)間:2018-09-09 18:06
【摘要】:針對(duì)成都市某垃圾填埋場(chǎng)滲濾液納濾出水中氯離子含量較高的特點(diǎn),通過(guò)理論分析和實(shí)際測(cè)樣篩選出適合測(cè)定滲濾液納濾出水有機(jī)物的國(guó)家標(biāo)準(zhǔn)推薦的檢測(cè)方法,即氯氣校正法。采用氯氣校正法對(duì)納濾出水COD進(jìn)行為期一個(gè)月的連續(xù)測(cè)定,結(jié)果表明,納濾出水COD值基本在50~75 mg/L之間波動(dòng),可以滿足《生活垃圾填埋場(chǎng)污染控制標(biāo)準(zhǔn)》(GB 16889—2008)的排放要求。且經(jīng)過(guò)成都市環(huán)保局多次取樣送第三方監(jiān)測(cè)后采用氯氣校正法測(cè)樣,納濾出水COD也達(dá)標(biāo),該環(huán)保工程已順利移交給業(yè)主運(yùn)營(yíng)。
[Abstract]:In view of the characteristics of high chlorine ion content in the landfill leachate of Chengdu, through theoretical analysis and practical sampling, the recommended detection method suitable for the determination of organic matter in the leachate nanofiltration water has been selected according to the national standard, which is suitable for the determination of organic matter in the leachate nanofiltration water. That is, chlorine gas correction method. The COD of nanofiltration water was determined by chlorine gas correction method for one month. The results show that the COD value of nanofiltration water fluctuates between 50 ~ 75 mg/L, which can meet the discharge requirements of "pollution Control Standard for domestic waste Landfill site" (GB 16889-2008). After repeated sampling and third party monitoring by Chengdu Environmental Protection Bureau, chlorine gas correction method was used to determine the sample, and the COD of nanofiltration water was also up to standard. The environmental protection project had been handed over to the owner for operation.
【作者單位】: 江蘇維爾利環(huán)?萍脊煞萦邢薰;
【分類號(hào)】:X832
本文編號(hào):2233159
[Abstract]:In view of the characteristics of high chlorine ion content in the landfill leachate of Chengdu, through theoretical analysis and practical sampling, the recommended detection method suitable for the determination of organic matter in the leachate nanofiltration water has been selected according to the national standard, which is suitable for the determination of organic matter in the leachate nanofiltration water. That is, chlorine gas correction method. The COD of nanofiltration water was determined by chlorine gas correction method for one month. The results show that the COD value of nanofiltration water fluctuates between 50 ~ 75 mg/L, which can meet the discharge requirements of "pollution Control Standard for domestic waste Landfill site" (GB 16889-2008). After repeated sampling and third party monitoring by Chengdu Environmental Protection Bureau, chlorine gas correction method was used to determine the sample, and the COD of nanofiltration water was also up to standard. The environmental protection project had been handed over to the owner for operation.
【作者單位】: 江蘇維爾利環(huán)?萍脊煞萦邢薰;
【分類號(hào)】:X832
【相似文獻(xiàn)】
相關(guān)期刊論文 前4條
1 王春冬;王壽兵;余志榮;史豪;;汽車工業(yè)乳化廢液超濾出水的生化處理研究[J];工業(yè)用水與廢水;2009年05期
2 崔理華,白瑛,張祖錫,房淑惠;城市污水人工快濾處理后回用的環(huán)境效應(yīng)研究[J];農(nóng)業(yè)環(huán)境保護(hù);1997年04期
3 謝志祥;三星小菜[J];烹調(diào)知識(shí);1994年08期
4 ;[J];;年期
相關(guān)會(huì)議論文 前1條
1 任軍;曹靜;;軋鋼乳化液超濾出水的中試治理研究[A];上海市巖土工程檢測(cè)中心論文集(1995—2005)[C];1995年
相關(guān)重要報(bào)紙文章 前1條
1 郭薇;水科院試驗(yàn)污水灌溉處理綜合技術(shù)[N];中國(guó)環(huán)境報(bào);2007年
相關(guān)碩士學(xué)位論文 前1條
1 張靜;超濾出水生物穩(wěn)定性影響因素研究[D];北京工業(yè)大學(xué);2011年
,本文編號(hào):2233159
本文鏈接:http://sikaile.net/kejilunwen/huanjinggongchenglunwen/2233159.html
最近更新
教材專著