二元非共沸混合工質(zhì)泄漏對有機(jī)朗肯循環(huán)性能及環(huán)境的影響
本文關(guān)鍵詞: 有機(jī)朗肯循環(huán) 混合工質(zhì)泄漏 環(huán)境火用成本 經(jīng)濟(jì)性 補(bǔ)液 出處:《重慶大學(xué)》2016年碩士論文 論文類型:學(xué)位論文
【摘要】:有機(jī)朗肯循環(huán)(Organic Rankine Cycle,ORC)由于設(shè)備簡單、操作方便等優(yōu)點(diǎn),近年來在低品位能源利用方面獲得迅速發(fā)展,是目前低品位能源開發(fā)利用技術(shù)研究的重點(diǎn)。利用非共沸混合工質(zhì)的 溫度滑移‖優(yōu)勢,能實(shí)現(xiàn)工質(zhì)在換熱設(shè)備中與冷熱源進(jìn)行較好地溫度匹配,從而減少換熱器中由傳熱溫差引起的不可逆損失。但有機(jī)工質(zhì)具有一定的全球變暖潛值、臭氧層損害潛值等環(huán)境影響,在HVAC(采暖空調(diào))領(lǐng)域,有機(jī)工質(zhì)泄漏引起的工質(zhì)組分以及循環(huán)性能的變化已受到普遍關(guān)注和研究,由于ORC采用同類有機(jī)工質(zhì),因此工質(zhì)泄漏對循環(huán)性能乃至環(huán)境的影響值得重視和加以研究。本文采用二元非共沸混合物R245fa/R601a和R114/R123為循環(huán)工質(zhì),對ORC系統(tǒng)蒸發(fā)器、冷凝器不同部位、泄漏率為0~30%的泄漏影響進(jìn)行了分析,在此基礎(chǔ)上建立了考慮泄漏工質(zhì)環(huán)境影響的系統(tǒng)火用平衡模型,用環(huán)境火用成本對混合工質(zhì)泄漏造成的環(huán)境影響進(jìn)行量化分析,并對ORC系統(tǒng)平準(zhǔn)化能量產(chǎn)出成本(Levelized Energy Cost,LEC)的評估方法提出修正,最后,根據(jù)二元非共沸混合工質(zhì)ORC的實(shí)際生產(chǎn)需要,提出補(bǔ)液配比方案。主要結(jié)論如下:(1)非共沸混合工質(zhì)泄漏將引起ORC運(yùn)行工質(zhì)配比變化,從而導(dǎo)致ORC系統(tǒng)性能偏離設(shè)計(jì)值。發(fā)生汽相泄漏時,高沸點(diǎn)組分比例增加,而發(fā)生液相泄漏時,低沸點(diǎn)組分比例增加。汽相泄漏引起的工質(zhì)配比變化率比液相泄漏的大。(2)非共沸混合工質(zhì)泄漏對ORC系統(tǒng)性能有較大影響。用綜合環(huán)境影響火用效率評價ORC系統(tǒng)熱力學(xué)性能,泄漏率為10%時,以R245fa/R601a(0.6/0.4)為循環(huán)工質(zhì)的火用效率減小3.9%,以R114/R123(0.8/0.2)為工質(zhì)的火用效率減小30%?拷淠鞒隹诘钠嘈孤⿲RC系統(tǒng)性能影響最大。(3)考慮混合工質(zhì)泄漏對ORC發(fā)電成本有較大的影響。當(dāng)泄漏率為10%時,以R245fa/R601a(0.6/0.4)為循環(huán)工質(zhì)的ORC系統(tǒng),考慮泄漏環(huán)境影響的LEC值比不考慮泄漏時增大10.4%(汽相泄漏)和8.3%(液相泄漏),以R114/R123(0.8/0.2)為循環(huán)工質(zhì)時,考慮泄漏環(huán)境影響的LEC比不考慮泄漏時增加89.8%(汽相泄漏)和81.6%(液相泄漏)。(4)對發(fā)生混合工質(zhì)泄漏之后的ORC系統(tǒng)進(jìn)行補(bǔ)液時,需要根據(jù)泄漏后的工質(zhì)配比計(jì)算補(bǔ)液配比。以R245fa/R601a(0.6/0.4)為例,當(dāng)泄漏率為10%,對系統(tǒng)性能影響較大的四種泄漏發(fā)生后的補(bǔ)液配比應(yīng)為0.38/0.62、0.35/0.65、0.64/0.36和0.66/0.34,不能簡單地按照原配比0.6/0.4進(jìn)行充注。
[Abstract]:Organic Rankine cycle ORC (Organic Rankine cycle ORC) has been developed rapidly in recent years because of its simple equipment and convenient operation. It is the focus of the research on the technology of low grade energy development and utilization at present. By using the advantage of non-azeotropic mixture of working fluids, it can achieve a better temperature matching between refrigerant and heat source in heat exchange equipment. In order to reduce the irreversible loss caused by the heat transfer temperature difference in the heat exchanger, but the organic working fluid has some environmental effects, such as global warming potential, ozone layer damage potential, in the field of HVAC (heating air conditioning). The changes of the components and cyclic properties of organic refrigerants caused by leakage of organic working fluids have been widely concerned and studied, because of the use of similar organic working fluids in ORC. Therefore, the effects of working fluid leakage on cycling performance and environment should be paid attention to and studied. In this paper, binary non-azeotropic mixtures R245fa / R601a and R114 / R123 are used as circulating working fluids. Based on the analysis of leakage effect of different parts of ORC system evaporator and condenser with leakage rate of 0 ~ 30%, a system exergy balance model considering the environmental impact of leakage working fluid is established. Environmental exergy cost is used to quantitatively analyze the environmental impact caused by the leakage of mixed working fluid, and to equalize the energy output cost of ORC system to the level Energy Cost. Finally, according to the actual production needs of binary non-azeotropic mixture ORC. The main conclusion is as follows: 1) the leakage of non-azeotropic mixture will cause the change of the working fluid ratio of ORC, which will cause the performance of ORC system to deviate from the design value. When the vapor phase leakage occurs, the performance of the ORC system will deviate from the design value. The ratio of high boiling point component increases, but the liquid phase leakage occurs. The ratio of low boiling point component increased. The change rate of working medium ratio caused by vapor phase leakage was larger than that of liquid phase leakage. The leakage of non-azeotropic mixture has great influence on the performance of ORC system. The thermodynamic performance of ORC system is evaluated by comprehensive environment influence exergy efficiency. When the leakage rate is 10, the exergy efficiency of R245faR / R601a0. 6 / 0. 4) as the circulating working medium is reduced by 3.9%. The exergy efficiency of R114 / R1230.8 / 0.2) was reduced by 30%. The vapor phase leakage near the condenser outlet had the greatest effect on the performance of ORC system. Considering the leakage of mixed working fluid has a great influence on the cost of ORC power generation. When the leakage rate is 10. A ORC system with R245FAR / R601a / 0.6 / 0.4) as the circulating working medium. The LEC value considering the environmental effects of leakage increases by 10.4 (vapor phase leakage) and 8.3 (liquid phase leakage) than when leakage is not considered. When R114 / R123N / 0.8 / 0.2) is used as a circulating working medium. LEC with environmental effects of leakage increased 89.8% and 81.6% respectively (liquid phase leakage) and 81.6% (liquid phase leakage) than when leakage was not considered. The rehydration of the ORC system after the leakage of the mixed working fluid is carried out. It is necessary to calculate the rehydration ratio according to the working fluid ratio after leakage. Take R 245fa / R 601a 0. 6 / 0. 4) as an example, when the leakage rate is 10%. The rehydration ratios of the four kinds of leakage which have a great influence on the system performance should be 0.38 / 0.62U / 0.35 / 0.65N / 0.64 / 0.36 and 0.66 / 0.34 respectively. It can not simply be filled with the original ratio of 0.6 / 0.4.
【學(xué)位授予單位】:重慶大學(xué)
【學(xué)位級別】:碩士
【學(xué)位授予年份】:2016
【分類號】:TK115
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 ;低溫混合工質(zhì)制冷研究獲進(jìn)展[J];機(jī)電設(shè)備;2002年02期
2 許名堯,吳沛宜;氮-烴類二元低溫混合工質(zhì)的工作機(jī)理分析[J];西安交通大學(xué)學(xué)報;1994年06期
3 樂子玲;微型J-T混合工質(zhì)制冷研究的進(jìn)展與水平[J];低溫工程;1995年02期
4 許名堯,何雅玲,陳鐘頎;多元氮-烴類混合工質(zhì)的工作機(jī)理分析[J];西安交通大學(xué)學(xué)報;1995年05期
5 陳光明,,侯虞鈞;基于最小傳熱熵增的混合工質(zhì)最佳組成[J];低溫物理學(xué)報;1996年04期
6 張鐠;鹿來運(yùn);郭開華;;一種混合工質(zhì)遴選、配比方法探討及實(shí)驗(yàn)驗(yàn)證[J];低溫工程;2013年06期
7 陳斌,陳光明,劉利華,洪峰,胡永亮;混合工質(zhì)變?nèi)萘空{(diào)節(jié)技術(shù)及其應(yīng)用[J];流體機(jī)械;2004年12期
8 譚連城,蔭建民;混合工質(zhì)制冷系統(tǒng)節(jié)能的熱力學(xué)分析[J];工程熱物理學(xué)報;1985年02期
9 許名堯,吳沛宜;二元氮──烴類低溫混合工質(zhì)的最佳配比分析[J];低溫與超導(dǎo);1994年03期
10 李頌哲;制冷混合工質(zhì)與替代問題[J];制冷;1996年01期
相關(guān)會議論文 前10條
1 陳光明;張麗娜;陳斌;;變濃度混合工質(zhì)空氣源熱泵系統(tǒng)的研究[A];第十二屆全國冷(熱)水機(jī)組與熱泵技術(shù)研討會論文集[C];2005年
2 趙佳威;郭開華;曾麗;舒碧芬;蒙宗信;;環(huán)保型混合工質(zhì)空調(diào)系統(tǒng)泄漏仿真研究[A];面向21世紀(jì)的科技進(jìn)步與社會經(jīng)濟(jì)發(fā)展(下冊)[C];1999年
3 王勤;陳光明;;多元混合工質(zhì)精餾循環(huán)的優(yōu)化計(jì)算與實(shí)驗(yàn)研究[A];第七屆全國冷凍干燥學(xué)術(shù)交流會論文集[C];2002年
4 甘智華;程章展;黃永華;陳國邦;邱利民;;氦氫混合工質(zhì)二級脈管制冷實(shí)驗(yàn)研究[A];第六屆全國低溫與制冷工程大會會議論文集[C];2003年
5 吳裕慶;張華;;混合工質(zhì)單級壓縮回?zé)嶂评湎到y(tǒng)的設(shè)計(jì)與性能分析[A];中國制冷學(xué)會2009年學(xué)術(shù)年會論文集[C];2009年
6 韓榮梅;魏躍文;谷波;;三元混合工質(zhì)HFC32/125/134a熱力參數(shù)模型分析[A];上海市制冷學(xué)會二○○一年學(xué)術(shù)年會論文集[C];2001年
7 趙力;涂光備;張啟;梁巖;沈川彬;;混合工質(zhì)在地?zé)釤岜孟到y(tǒng)中的實(shí)驗(yàn)研究[A];全國暖通空調(diào)制冷2000年學(xué)術(shù)年會論文集[C];2000年
8 齊延峰;公茂瓊;曹勇;吳劍峰;;混合工質(zhì)制冷系統(tǒng)中節(jié)流元件毛細(xì)管的兩種計(jì)算方法比較[A];第五屆全國低溫工程大會論文集[C];2001年
9 錢文波;晏剛;馮永斌;陶鍇;張敏;楊一帆;閻承濤;;冷凍陳列柜應(yīng)用混合工質(zhì)R290/R134A替代R404A的實(shí)驗(yàn)研究[A];全國冷凍、冷藏行業(yè)制冷安全技術(shù)、節(jié)能、環(huán)保新技術(shù)發(fā)展研討會論文集[C];2009年
10 裴秀英;李樹林;;混合工質(zhì)R32/R134a對環(huán)境的影響分析[A];2001福建省冷藏技術(shù)研討會論文集[C];2001年
相關(guān)重要報紙文章 前1條
1 唐偉;新型深冷混合工質(zhì)節(jié)流制冷技術(shù)世界領(lǐng)先[N];科技日報;2006年
相關(guān)博士學(xué)位論文 前9條
1 郭叢;有機(jī)朗肯循環(huán)系統(tǒng)集成及蒸發(fā)過程性能研究[D];華北電力大學(xué);2015年
2 龐偉強(qiáng);低溫制冷系統(tǒng)混合工質(zhì)兩相流動傳熱特性及濃度優(yōu)化研究[D];華南理工大學(xué);2016年
3 許雄文;非共沸混合工質(zhì)制冷系統(tǒng)工質(zhì)濃度變化及其性能優(yōu)化研究[D];華南理工大學(xué);2012年
4 王方;基于傳熱窄點(diǎn)的熱泵用HFC125/HCs混合工質(zhì)優(yōu)選及其系統(tǒng)特性研究[D];上海交通大學(xué);2012年
5 朱洪波;深冷溫區(qū)多元混合工質(zhì)汽液相平衡特性研究[D];中國科學(xué)院研究生院(理化技術(shù)研究所);2007年
6 張仙平;熱泵系統(tǒng)用R744混合工質(zhì)特性的研究[D];東華大學(xué);2011年
7 陳建新;混合工質(zhì)熱物性推算新方法及PVTx測試研究[D];中國科學(xué)技術(shù)大學(xué);2007年
8 王勤;混合工質(zhì)節(jié)流制冷機(jī)的理論與實(shí)驗(yàn)研究[D];浙江大學(xué);2002年
9 張麗娜;變濃度熱泵系統(tǒng)的理論與實(shí)驗(yàn)研究[D];浙江大學(xué);2007年
相關(guān)碩士學(xué)位論文 前10條
1 劉亞東;丙酮-乙醇二元混合液相熱力學(xué)性質(zhì)分析[D];南京理工大學(xué);2015年
2 王重陽;混合工質(zhì)有機(jī)朗肯循環(huán)與熱源匹配關(guān)系的研究[D];重慶大學(xué);2015年
3 湯磊;基于混合工質(zhì)的低品位熱能發(fā)電系統(tǒng)性能實(shí)驗(yàn)研究[D];上海交通大學(xué);2015年
4 張鹿;R32/R600a用于循環(huán)加熱式熱泵熱水器的試驗(yàn)研究[D];中原工學(xué)院;2016年
5 高媛媛;內(nèi)燃機(jī)排氣余熱利用有機(jī)朗肯循環(huán)混合工質(zhì)的分析研究[D];天津大學(xué);2014年
6 解西敏;低溫余熱二元非共沸混合工質(zhì)噴射式發(fā)電制冷系統(tǒng)優(yōu)化研究[D];重慶大學(xué);2016年
7 達(dá)紅梅;二元非共沸混合工質(zhì)泄漏對有機(jī)朗肯循環(huán)性能及環(huán)境的影響[D];重慶大學(xué);2016年
8 康振華;中低溫有機(jī)朗肯循環(huán)混合工質(zhì)性能分析及其傳熱特性研究[D];天津大學(xué);2014年
9 鄒曉超;多元混合工質(zhì)相平衡及傳熱模擬與系統(tǒng)實(shí)驗(yàn)研究[D];華中科技大學(xué);2008年
10 方錦;新工質(zhì)飽和蒸氣壓實(shí)驗(yàn)及混合工質(zhì)氣液相平衡研究[D];清華大學(xué);2008年
本文編號:1467621
本文鏈接:http://sikaile.net/kejilunwen/dongligc/1467621.html