開窗對具有輻射冷頂板空調(diào)系統(tǒng)的室內(nèi)熱環(huán)境的影響分析
本文關(guān)鍵詞:開窗對具有輻射冷頂板空調(diào)系統(tǒng)的室內(nèi)熱環(huán)境的影響分析 出處:《湖南大學(xué)》2015年碩士論文 論文類型:學(xué)位論文
更多相關(guān)文章: 輻射冷頂板 室內(nèi)熱環(huán)境 溫度分布 負(fù)荷計算 CFD模擬
【摘要】:隨著社會對建筑節(jié)能的重視,輻射冷頂板作為一種節(jié)能效果明顯的空調(diào)形式越來越受到業(yè)界關(guān)注。輻射冷頂板空調(diào)系統(tǒng)的優(yōu)勢不僅在于其節(jié)能性,還在于其良好的舒適性。本文的主要研究對象為具有輻射冷頂板空調(diào)系統(tǒng)的室內(nèi)熱環(huán)境。目前對具有輻射冷頂板空調(diào)的室內(nèi)熱環(huán)境的研究中,主要考慮的影響因素是輻射冷頂板的傳熱特性、頂板工作溫度、通風(fēng)系統(tǒng)的送風(fēng)溫度和送風(fēng)速度等固有因素,而對人為因素如開窗、開門等行為的考慮很少。本文分析研究了開窗對具有輻射冷頂板空調(diào)系統(tǒng)的室內(nèi)熱環(huán)境的影響。文章首先介紹了輻射供冷技術(shù)的發(fā)展、研究現(xiàn)狀以及輻射冷頂板系統(tǒng)的特點、分類,并對輻射冷頂板空調(diào)系統(tǒng)的設(shè)計方法和傳熱過程做了介紹。通過實驗的方式研究了開窗對具有輻射冷頂板的室內(nèi)熱環(huán)境的影響,實驗中測量的數(shù)據(jù)包括房間壁面溫度、室內(nèi)空氣溫濕度等。實驗結(jié)果表明:開窗后室內(nèi)空氣溫度變化迅速,幅度大,且上部空氣溫度變化比下部空氣更為劇烈。開窗5分鐘內(nèi)是室內(nèi)空氣溫度變化程度最大的,隨著時間的推移,室內(nèi)空氣溫度變化速度越來越慢,幅度也越來越小,55分鐘時室內(nèi)熱環(huán)境趨于穩(wěn)定。同時,通過CFD模擬的方法對開窗后具有輻射冷頂板空調(diào)的室內(nèi)熱環(huán)境的變化情況進(jìn)行了模擬研究。建立了輻射冷頂板空調(diào)系統(tǒng)房間的物理模型,通過負(fù)荷計算確定了房間各項負(fù)荷。模擬結(jié)果顯示:開窗后首先受到影響的是房間的上部空氣,且溫度變化響應(yīng)迅速,而房間工作區(qū)的空氣溫度變化較為緩和;房間空氣的升溫過程有一定的方向性,主要是由上至下,由發(fā)熱體頂部至發(fā)熱體四周,且室內(nèi)空氣的升溫速度是逐漸減慢的;房間上部空氣有較大的溫度梯度,但是工作區(qū)的溫度梯度不大,人體頭部以及腳踝之間的溫差始終保持在可接受范圍內(nèi);與實驗結(jié)果相比模擬中房間空氣溫度升高幅度較小,由此可以得出開窗對較大房間的影響要明顯小于較小房間。
[Abstract]:With the attention of the society to the building energy saving, the radiation cooling roof as a kind of air conditioning with obvious energy-saving effect has attracted more and more attention. The advantage of the radiation cold roof air conditioning system lies not only in its energy conservation. The main research object of this paper is the indoor thermal environment with radiant cold roof air conditioning system. The main factors considered are the heat transfer characteristics of the radiant cold roof, the working temperature of the roof, the air supply temperature and the air velocity of the ventilation system, and the artificial factors such as window opening. The effect of window opening on the indoor thermal environment with radiant cooling roof air conditioning system is analyzed and studied in this paper. Firstly, the development of radiation cooling technology is introduced. The research status and the characteristics and classification of radiation cold roof system. The design method and heat transfer process of radiant cold roof air conditioning system are introduced. The effect of window opening on the indoor thermal environment with radiant cold roof is studied through experiments. The measured data include room wall temperature, indoor air temperature and humidity, etc. The experimental results show that the indoor air temperature changes rapidly and greatly after opening the window. The change of upper air temperature is more intense than that of lower air. The change of indoor air temperature is the biggest in 5 minutes, and with the passage of time, the indoor air temperature changes more and more slowly. The range is getting smaller and smaller, and the indoor thermal environment tends to be stable after 55 minutes. At the same time. The change of indoor thermal environment with radiant cold roof air conditioning after window opening was simulated by CFD simulation method, and the physical model of the room of radiation cold roof air conditioning system was established. The simulation results show that the upper air of the room is first affected by the window opening, and the temperature response is rapid, while the air temperature change in the working area of the room is relatively moderate. The heating process of the room air has certain directionality, mainly from the top to the bottom, from the top of the heating body to around the heat body, and the heating rate of the indoor air is gradually slowed down; The air in the upper part of the room has a large temperature gradient, but the temperature gradient of the working area is small, and the temperature difference between the human head and the ankle is always in acceptable range; Compared with the experimental results, the temperature of room air in the simulation is smaller than that in the small room, so it can be concluded that the effect of window opening on the larger room is obviously smaller than that of the smaller room.
【學(xué)位授予單位】:湖南大學(xué)
【學(xué)位級別】:碩士
【學(xué)位授予年份】:2015
【分類號】:TU111
【參考文獻(xiàn)】
相關(guān)期刊論文 前10條
1 雷會玉;余曉明;朱祥政;張曉;;毛細(xì)管輻射空調(diào)系統(tǒng)的節(jié)能性分析[J];能源工程;2014年02期
2 張華娣;錢華;鄭曉紅;趙宜麗;;南京地區(qū)兒童父母病態(tài)建筑綜合癥與家居環(huán)境因素的相關(guān)性分析[J];東南大學(xué)學(xué)報(自然科學(xué)版);2014年02期
3 周根明;殷浪華;周少華;;貼附射流-輻射板與置換通風(fēng)-輻射板的對比分析[J];江蘇科技大學(xué)學(xué)報(自然科學(xué)版);2012年05期
4 張巖;馮圣紅;;頂板輻射供冷房間節(jié)能性的探討[J];建筑節(jié)能;2012年02期
5 周根明;施穎;路詩奎;陳育平;趙忠超;;輻射供冷與貼附射流復(fù)合空調(diào)系統(tǒng)防結(jié)露研究[J];建筑熱能通風(fēng)空調(diào);2011年05期
6 施穎;陳育平;孔祥雷;周根明;;輻射供冷與貼附射流復(fù)合空調(diào)系統(tǒng)空氣品質(zhì)研究[J];暖通空調(diào);2011年02期
7 葉婷;李銳;;頂板輻射供冷與置換通風(fēng)復(fù)合式空調(diào)系統(tǒng)優(yōu)化研究[J];廣州大學(xué)學(xué)報(自然科學(xué)版);2010年05期
8 康寧;宣永梅;殷清海;;輻射供冷加置換通風(fēng)系統(tǒng)的數(shù)值模擬研究[J];制冷與空調(diào)(四川);2009年06期
9 孫亭;刁乃仁;李剛;;頂板輻射供冷與置換通風(fēng)的實驗研究[J];建筑熱能通風(fēng)空調(diào);2009年02期
10 祝合虎;陳九法;胡達(dá)劍;;置換通風(fēng)輻射空調(diào)不同結(jié)合方式的模擬比較[J];建筑熱能通風(fēng)空調(diào);2008年06期
相關(guān)博士學(xué)位論文 前2條
1 王晉生;加裝長波高透過性薄膜的冷卻頂板/置換通風(fēng)系統(tǒng)實驗與模擬[D];同濟(jì)大學(xué);2006年
2 劉艷峰;地板供暖設(shè)計與運(yùn)行基礎(chǔ)理論研究[D];西安建筑科技大學(xué);2004年
相關(guān)碩士學(xué)位論文 前4條
1 武雁林;輻射冷頂板表面發(fā)射率的研究和室內(nèi)熱環(huán)境分析[D];湖南大學(xué);2013年
2 沈酬;農(nóng)村自然通風(fēng)住宅室內(nèi)熱舒適性研究[D];西南交通大學(xué);2011年
3 劉鵬;獨立新風(fēng)結(jié)合輻射冷吊頂系統(tǒng)節(jié)能舒適性研究[D];華中科技大學(xué);2009年
4 張佩東;輻射供冷—置換通風(fēng)室內(nèi)熱環(huán)境及動態(tài)響應(yīng)特性研究[D];西安建筑科技大學(xué);2008年