天津辦公建筑節(jié)能措施的經(jīng)濟(jì)效益分析
本文選題:辦公建筑 + 節(jié)能措施 ; 參考:《天津大學(xué)》2014年碩士論文
【摘要】:我國(guó)建筑用能已經(jīng)超過(guò)全國(guó)能源消費(fèi)總量的27.5%,而且建筑能耗比例仍將隨建設(shè)總量的加速增長(zhǎng)而提高。圍護(hù)結(jié)構(gòu)和空調(diào)系統(tǒng)是影響建筑能耗的主要方面,本文依據(jù)即將頒布的天津市公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn),以eQUEST能耗模擬軟件為研究工具,對(duì)一系列節(jié)能措施的經(jīng)濟(jì)效益進(jìn)行分析,以此研究了各節(jié)能措施的節(jié)能潛力大小,本文還對(duì)各節(jié)能措施作了敏感性分析,并對(duì)敏感性大小進(jìn)行了排序。這些節(jié)能措施包括:降低外墻和屋面的傳熱系數(shù)、使用節(jié)能型玻璃和窗框型材、加強(qiáng)外窗保溫構(gòu)造、加設(shè)外遮陽(yáng)、使用節(jié)能型玻璃幕墻、提高機(jī)組性能系數(shù)、采用適宜機(jī)組運(yùn)行臺(tái)數(shù)方案、采用大溫差小流量系統(tǒng)、使用變頻水泵、加設(shè)排風(fēng)熱回收裝置以及提高水泵和風(fēng)機(jī)效率。研究表明:在考慮降低建筑能耗時(shí)應(yīng)同時(shí)考慮所帶來(lái)的經(jīng)濟(jì)效益,不能為追求低能耗而忽略其所帶來(lái)的初投資。對(duì)于本文外墻和屋面負(fù)荷占到圍護(hù)結(jié)構(gòu)負(fù)荷將近30%的辦公建筑而言,使全生命周期費(fèi)用最少的外墻巖棉保溫板厚度為90~110mm,屋面擠塑保溫板厚度為110~130mm,而若要達(dá)到經(jīng)濟(jì)保溫厚度,與做保溫之前,單位外墻、屋面面積可以節(jié)省的電能分別為25.89kWh、37.90kWh。雙層Low-e中空玻璃節(jié)能潛力較大,與普通雙層中空玻璃相比,每平方米外窗面積可以節(jié)省29.63kWh電能;與普通單層玻璃相比,每平方米外窗面積可以節(jié)省58.86kWh電能,而且2~3年就可以回收,應(yīng)用前景很好。機(jī)組運(yùn)行臺(tái)數(shù)應(yīng)適宜,對(duì)于本文295kW的制冷負(fù)荷來(lái)說(shuō),以3臺(tái)最佳,且應(yīng)按“兩大帶一小”負(fù)荷分配方案配置。采用變頻水泵和排風(fēng)熱回收裝置可以降低機(jī)組運(yùn)行時(shí)的負(fù)荷,每年可節(jié)約近萬(wàn)度電,普通水泵變頻器2-3年就可以回收,排風(fēng)熱回收裝置回收期也不超過(guò)4年。水泵、風(fēng)機(jī)效率的提高可以在一定區(qū)間內(nèi)獲得較好的經(jīng)濟(jì)效益,本文中水泵能耗占空調(diào)能耗20%左右時(shí),水泵效率在70%為宜,風(fēng)機(jī)效率則以70-80%為宜。機(jī)組的運(yùn)行臺(tái)數(shù)方案和使用節(jié)能型外窗玻璃當(dāng)投入相同比例的資金時(shí),獲得的經(jīng)濟(jì)效益會(huì)比其它節(jié)能措施更多。外墻、屋面保溫和加設(shè)活動(dòng)外遮陽(yáng)雖然節(jié)能潛力沒有采用較好的設(shè)備運(yùn)行策略和加強(qiáng)外窗熱工性能大,但其初投入回收期不長(zhǎng),壽命周期內(nèi)經(jīng)濟(jì)效益良好。
[Abstract]:The building energy consumption in China has exceeded the total energy consumption of the whole country by 27.5%, and the proportion of building energy consumption will still increase with the acceleration of the total construction amount. The envelope structure and air conditioning system are the main aspects that affect the building energy consumption. According to the design standard of energy conservation of public buildings in Tianjin, this paper analyzes the economic benefits of a series of energy-saving measures by using eQUEST energy consumption simulation software as the research tool. In this paper, the potential of each energy-saving measure is studied, and the sensitivity of each energy-saving measure is analyzed, and the order of the sensitivity is given. These energy-saving measures include: reducing the heat transfer coefficient of external walls and roofs, using energy-efficient glass and window frame profiles, strengthening the insulation structure of outer windows, adding external shading, using energy-efficient glass curtain walls, and improving the performance coefficient of the units. It adopts the suitable operation table scheme, adopts the large temperature difference small flow system, uses the frequency conversion water pump, adds the exhaust air heat recovery device, and improves the efficiency of the pump and the fan. The results show that the economic benefits should be taken into account when reducing building energy consumption, and the initial investment should not be ignored in order to pursue low energy consumption. For the office buildings with external walls and roof loads accounting for nearly 30% of the enclosing structure load, The thickness of the outer wall rock wool insulation board with the lowest life cycle cost is 90 ~ 110mm and the thickness of the roof extruded insulation board is 110 ~ 130mm. In order to achieve the economic insulation thickness, the electric energy saved on the external wall per unit roof area is 25.89 kWh-37.90 kWh. if the thermal insulation is to be achieved. Compared with ordinary double-layer hollow glass, double-layer Low-e hollow glass can save 29.63 kWh electric energy per square meter window area and 58.86 kWh energy per square meter window area compared with ordinary single-layer glass, compared with common double-layer hollow glass, double-layer hollow glass can save 29.63 kWh electric energy per square meter of outer window area. Moreover 2 ~ 3 years can be recycled, the application prospect is very good. For the 295kW refrigeration load of this paper, 3 units should be the best, and should be allocated according to the "two big belt and one small" load distribution scheme. Adopting frequency conversion pump and exhaust heat recovery device can reduce the load of unit operation, save nearly ten thousand degrees of electricity every year, can be recovered by ordinary pump inverter in 2-3 years, and the recovery period of exhaust heat recovery device is not more than 4 years. In this paper, when the energy consumption of water pump is about 20% of air conditioning energy consumption, the pump efficiency is 70%, and the fan efficiency is 70-80%. When the same proportion of capital is invested in the operation of the unit and the energy saving window glass is used, the economic benefit will be more than that of other energy-saving measures. Although the energy saving potential of external wall, roof heat preservation and active sun shading is not good, but the initial payback period is not long, and the economic benefit is good in the life cycle, the thermal performance of the external wall and roof is not improved by adopting better equipment operation strategy and strengthening the thermal performance of the outer window.
【學(xué)位授予單位】:天津大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2014
【分類號(hào)】:TU201.5
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 劉衡;建筑的綜合節(jié)能措施[J];墻材革新與建筑節(jié)能;2001年02期
2 ;英國(guó)節(jié)能措施[J];內(nèi)蒙古電力技術(shù);2004年04期
3 陳晨;潘毅群;;無(wú)成本、低成本節(jié)能措施在商用建筑中的應(yīng)用[J];制冷空調(diào)與電力機(jī)械;2006年01期
4 付興華;;建筑工程擴(kuò)建過(guò)程中節(jié)能措施研究——以貴和購(gòu)物中心二期為例[J];黑龍江科技信息;2011年09期
5 楊俊峰;我廠工藝泵的節(jié)能措施[J];化工煉油機(jī)械;1981年04期
6 基;;節(jié)能措施投資的回收期與回收率[J];能源工程;1982年02期
7 李國(guó)治;;日本東芝公司的冰箱節(jié)能措施[J];家用電器科技;1984年04期
8 曉光;熱處理操作中的節(jié)能事例[J];洪都科技;1987年02期
9 劉存玉;美國(guó)一些公司的節(jié)能措施[J];節(jié)能技術(shù);1987年06期
10 歐陽(yáng)惠芳;;煤爐的幾項(xiàng)節(jié)能措施[J];可再生能源;1990年03期
相關(guān)會(huì)議論文 前10條
1 高霖;;綜合節(jié)能在建筑工程上的有效利用——科技部能源示范樓設(shè)計(jì)實(shí)例介紹[A];加入WTO和中國(guó)科技與可持續(xù)發(fā)展——挑戰(zhàn)與機(jī)遇、責(zé)任和對(duì)策(下冊(cè))[C];2002年
2 孫春裕;;江浦冷凍廠節(jié)能措施[A];上海市制冷學(xué)會(huì)二○○一年學(xué)術(shù)年會(huì)論文集[C];2001年
3 周武成;;某貨運(yùn)冷庫(kù)的節(jié)能措施[A];第六屆全國(guó)食品冷藏鏈大會(huì)論文集[C];2008年
4 馬素貞;龍惟定;;解讀1995版和2006版ASHRAE Standard 100——既有建筑中的節(jié)能措施[A];全國(guó)暖通空調(diào)制冷2008年學(xué)術(shù)年會(huì)資料集[C];2008年
5 牛建會(huì);劉澤勤;;冷庫(kù)節(jié)能措施的幾點(diǎn)建議[A];第3屆中國(guó)食品冷藏鏈新設(shè)備、新技術(shù)論壇論文集[C];2007年
6 馬素貞;龍惟定;;解讀1995版和2006版ASHRAE Standard 100——既有建筑中的節(jié)能措施[A];上海市制冷學(xué)會(huì)2007年學(xué)術(shù)年會(huì)論文集[C];2007年
7 焦永道;彭毅;;袋、電除塵器性能比較及節(jié)能措施[A];東南十省市水泥發(fā)展論壇會(huì)刊[C];2007年
8 張海榮;沈劍;諶金虎;張海波;;推廣綠色建筑,創(chuàng)建節(jié)約型工地[A];施工機(jī)械化新技術(shù)交流會(huì)論文集(第十一輯)[C];2010年
9 杜柳柳;沈恒根;婁可賓;;淺談紡織廠空調(diào)的節(jié)能措施與應(yīng)用[A];全國(guó)紡織空調(diào)除塵新技術(shù)、新設(shè)備、新成果研討會(huì)論文集[C];2007年
10 王廣杉;;船舶節(jié)能措施小議[A];中國(guó)航海學(xué)會(huì)航標(biāo)專業(yè)委員會(huì)沿海、內(nèi)河航標(biāo)學(xué)組聯(lián)合年會(huì)學(xué)術(shù)交流論文集[C];2003年
相關(guān)重要報(bào)紙文章 前10條
1 甕長(zhǎng)龍;節(jié)能重在強(qiáng)化管理[N];東北電力報(bào);2004年
2 通訊員 陳波;大連石化建立節(jié)能措施運(yùn)行查詢系統(tǒng)[N];中國(guó)石油報(bào);2007年
3 記者 孔生;商品房應(yīng)明示節(jié)能措施[N];揚(yáng)州日?qǐng)?bào);2009年
4 岳德亮;浙江商品房說(shuō)明書須明示節(jié)能措施等信息[N];中國(guó)建材報(bào);2007年
5 記者 鄭娜 實(shí)習(xí)生 陳寧;建筑不節(jié)能 罰款50萬(wàn)[N];發(fā)展導(dǎo)報(bào);2007年
6 記者 楊麗英 張春亮;太原新建建筑今年須過(guò)“節(jié)能關(guān)”[N];中國(guó)冶金報(bào);2006年
7 郭妍;濰坊發(fā)電廠全盤優(yōu)化節(jié)能措施[N];中國(guó)電力報(bào);2004年
8 清華大學(xué)建筑學(xué)院副教授 周正楠 整理;被動(dòng)式節(jié)能措施的能耗影響[N];中國(guó)房地產(chǎn)報(bào);2010年
9 陳小列;既有建筑應(yīng)率先節(jié)能改造[N];中國(guó)建設(shè)報(bào);2012年
10 黃振琳 張文娟;節(jié)能小區(qū)冷熱兩重天[N];中國(guó)改革報(bào);2009年
相關(guān)碩士學(xué)位論文 前4條
1 邵鑫彤;天津辦公建筑節(jié)能措施的經(jīng)濟(jì)效益分析[D];天津大學(xué);2014年
2 牛方方;高速公路營(yíng)運(yùn)期節(jié)能措施及效果研究[D];長(zhǎng)安大學(xué);2013年
3 郭若穎;太原和易達(dá)公司節(jié)能措施分析與合金鑄件項(xiàng)目節(jié)能評(píng)估[D];華北電力大學(xué);2012年
4 張志彬;蘭州地區(qū)高校校園建筑能耗分析及節(jié)能措施初探[D];西安建筑科技大學(xué);2013年
,本文編號(hào):2010387
本文鏈接:http://sikaile.net/guanlilunwen/chengjian/2010387.html