16排CT血管成像在腹主動脈及下肢阻塞性病變診斷中的價值
發(fā)布時間:2018-12-18 01:45
【摘要】:目的:分析研討16排血管成像在腹主動脈及下肢阻塞性病變診斷中的價值。方法:此研究中所討論的30例患者均隨機選取于2014年1月-2015年8月期間我院收治的腹主動脈及下肢阻塞性病變患者中,患者均接受16排CT血管成像和三維重建診斷,其掃描范圍為1100mm-1200mm,給予密度最大投影,表面陰影重建和溶積再現,分析其診斷結果。結果:靜脈顯影:30例患者中共29例接受了血管成像檢查,1例靜脈曲張未接受血管成像檢查,僅接受靜脈顯影觀察。30例患者股總靜脈一側處于正常,其靜脈顯影共26例顯影優(yōu)良,優(yōu)良率為86.67%,包含優(yōu)秀17例,良好9例。各病例顯影均符合診斷要求。共檢出29例下肢靜脈存在阻塞性病變,和DSA檢查符合率為96.67%(29/30)。結論:16排CT血管成像屬于一項非侵襲性和高準確度的成像檢查方式,在腹主動脈及下肢阻塞性病變診斷中特異性、敏感性、準確性。
[Abstract]:Objective: to study the diagnostic value of 16-row angiography in abdominal aorta and lower extremity obstructive diseases. Methods: thirty patients with abdominal aorta and lower extremity obstructive diseases were randomly selected from January 2014 to August 2015. All patients were diagnosed by 16-row CT angiography and 3D reconstruction. The scanning range is 1100mm-1200mm, with maximum density projection, surface shadow reconstruction and dissolution reconstruction, and the diagnostic results are analyzed. Results: venous imaging was performed in 29 cases of 30 patients, 1 case of varicose vein was not examined by angiography, only vein was observed, and 30 cases of common femoral vein were normal. There were 26 cases with excellent development of vein, the excellent and good rate was 86.67, including excellent 17 cases and good 9 cases. All cases were in accordance with the diagnostic requirements. A total of 29 patients with obstructive lesions of lower extremity veins were detected, and the coincidence rate with DSA was 96.67% (29 / 30). Conclusion: 16-row CT angiography is a noninvasive and highly accurate imaging method, which is specific, sensitive and accurate in the diagnosis of abdominal aorta and lower extremity obstructive diseases.
【作者單位】: 阜寧縣人民醫(yī)院CT室;
【分類號】:R816.2;R543
[Abstract]:Objective: to study the diagnostic value of 16-row angiography in abdominal aorta and lower extremity obstructive diseases. Methods: thirty patients with abdominal aorta and lower extremity obstructive diseases were randomly selected from January 2014 to August 2015. All patients were diagnosed by 16-row CT angiography and 3D reconstruction. The scanning range is 1100mm-1200mm, with maximum density projection, surface shadow reconstruction and dissolution reconstruction, and the diagnostic results are analyzed. Results: venous imaging was performed in 29 cases of 30 patients, 1 case of varicose vein was not examined by angiography, only vein was observed, and 30 cases of common femoral vein were normal. There were 26 cases with excellent development of vein, the excellent and good rate was 86.67, including excellent 17 cases and good 9 cases. All cases were in accordance with the diagnostic requirements. A total of 29 patients with obstructive lesions of lower extremity veins were detected, and the coincidence rate with DSA was 96.67% (29 / 30). Conclusion: 16-row CT angiography is a noninvasive and highly accurate imaging method, which is specific, sensitive and accurate in the diagnosis of abdominal aorta and lower extremity obstructive diseases.
【作者單位】: 阜寧縣人民醫(yī)院CT室;
【分類號】:R816.2;R543
【相似文獻】
相關期刊論文 前10條
1 李開成;余強;羅濟程;;下肢血栓閉塞性脈管炎的多層螺旋CT血管成像[J];中國醫(yī)學計算機成像雜志;2007年04期
2 程曉青;左長京;田建明;呂桃珍;郝強;邵成偉;;64層螺旋CT血管成像在腦血管疾病中的應用[J];醫(yī)學影像學雜志;2008年02期
3 S. Feuerlein;E. Roessl;R. Proksa;G. Martens;O. Klass;M. Jeltsch;胡鵬;;多能量光子計數K緣影像提高血管成像中管腔顯示的可能[J];國際醫(yī)學放射學雜志;2009年01期
4 汪珍元;楊俊凱;王彩云;;40層螺旋CT血管成像在下肢閉塞性動脈硬化癥診斷中的應用價值[J];實用醫(yī)學影像雜志;2011年01期
5 趙偉;任千里;陳龍;祝洪福;;64層螺旋CT血管成像對下肢動脈硬化閉塞癥的診斷價值[J];臨床醫(yī)學;2012年03期
6 ;書訊[J];國際醫(yī)學放射學雜志;2012年06期
7 楊亞英,張龍江,宋光義;多層螺旋CT頸部血管成像[J];放射學實踐;2004年10期
8 苑靜波,劉沖,賈麗英,趙青,叩新軍,徐麗梅;多層螺旋CT腹部血管成像應用研究[J];實用放射學雜志;2005年08期
9 葛英輝;呂傳劍;萬曉e,