人體胸壁厚度對肺部計數(shù)器探測效率的影響研究
本文選題:肺部計數(shù)器 + 體素模型。 參考:《核電子學(xué)與探測技術(shù)》2015年12期
【摘要】:人體胸壁厚度是影響肺部放射性核素測量準(zhǔn)確性的重要參數(shù);跀(shù)字體素模型和MC法,計算得到了不同胸壁厚度條件下,肺部計數(shù)器對241Am出射光子的探測效率,進(jìn)而研究了3組不同人群胸壁厚度差異造成的探測效率偏差。結(jié)果顯示:胸壁厚度對241Am測量結(jié)果的影響嚴(yán)重,出射光子能量越低胸壁厚度影響越大;相較平均胸壁厚度時的探測效率,對于17.6keV光子,偏差可達(dá)308.0%,對于59.5keV光子,偏差可達(dá)50.0%。
[Abstract]:The thickness of human chest wall is an important parameter that affects the accuracy of radionuclide measurement. Based on the digital voxel model and MC method, the detection efficiency of 241Am emission photon by lung counter under different chest wall thickness conditions was calculated, and the detection efficiency deviation caused by the difference of chest wall thickness in three groups of people was studied. The results show that the thickness of chest wall has a serious effect on the measurement results of 241Am, the lower the energy of emerging photon, the greater the thickness of chest wall, and the detection efficiency of the average thickness of chest wall is 308.0 for 17.6 KeV photons and 50.0 for 59.5 Kev photons.
【作者單位】: 西北核技術(shù)研究所;
【分類號】:R14
【相似文獻(xiàn)】
相關(guān)期刊論文 前6條
1 成智威;毛永;馬如維;陳寶維;韓月琴;田自寧;巨凌軍;董正鵬;;超鈾元素肺部計數(shù)器的效率刻度技術(shù)[J];輻射防護(hù);2009年06期
2 成智威;申茂泉;張洋;;小波分析方法在肺部計數(shù)器解譜中的應(yīng)用[J];中國輻射衛(wèi)生;2012年03期
3 張斌全;馬吉增;程建平;楊端節(jié);劉立業(yè);;使用人體軀干物理模型的CT模型和蒙特卡羅方法校準(zhǔn)肺部計數(shù)器[J];輻射防護(hù);2006年02期
4 成智威;賈明雁;程建平;申茂泉;黎先利;田自寧;巨凌軍;;肺部計數(shù)器測量肺內(nèi)氡子體的可行性研究[J];中國輻射衛(wèi)生;2011年01期
5 劉立業(yè);Didier Franck;Loicde Carlan;馬吉增;張斌全;;基于Livermore模型CT圖片構(gòu)建人體軀干數(shù)字體模及其在肺部計數(shù)器虛擬刻度中的應(yīng)用[J];輻射防護(hù);2007年05期
6 ;[J];;年期
相關(guān)會議論文 前1條
1 成智威;田自寧;巨凌軍;;超鈾元素肺部計數(shù)器的效率刻度[A];全國個人劑量監(jiān)測研討會論文匯編[C];2008年
相關(guān)博士學(xué)位論文 前1條
1 成智威;基于肺部計數(shù)器的內(nèi)照射監(jiān)測和劑量評價技術(shù)研究[D];清華大學(xué);2014年
相關(guān)碩士學(xué)位論文 前1條
1 田言杰;峰谷比法測量等效胸壁厚度技術(shù)研究[D];哈爾濱工程大學(xué);2013年