天堂国产午夜亚洲专区-少妇人妻综合久久蜜臀-国产成人户外露出视频在线-国产91传媒一区二区三区

當(dāng)前位置:主頁 > 醫(yī)學(xué)論文 > 外科論文 >

應(yīng)用兩種不同材質(zhì)融合器行腰椎椎間融合的三維有限元分析

發(fā)布時(shí)間:2018-09-13 14:31
【摘要】:背景:脊柱生物力學(xué)的發(fā)展日新月異,尤其近年來,各種新技術(shù)、新方法層出,椎弓根螺釘固定聯(lián)合椎間融合器(cage)在臨床上逐漸普及,使得脊柱手術(shù)節(jié)段廣泛骨性減壓后能得到即刻穩(wěn)定,并通過植骨達(dá)到遠(yuǎn)期融合從而維持其正常功能。cage有著自身特有的一些優(yōu)勢(shì),不但增加了椎體融合率,減少了植骨量的使用,又可以恢復(fù)椎間隙的既有高度,加快融合速率,減少手術(shù)時(shí)間,現(xiàn)在已發(fā)展為脊柱外科基本的技術(shù)之一。但隨著融合器使用量的增加,也出現(xiàn)了一些融合失敗的例子,如cage的移位、沉陷等。針對(duì)以上失敗的例子,我們對(duì)椎弓根螺釘聯(lián)合cage的生物力學(xué)特性做了大量實(shí)驗(yàn)探索及測(cè)試[1],對(duì)于椎弓根螺釘實(shí)驗(yàn)主要集中在器械抗疲勞,螺釘拔出力及螺釘?shù)氖芰Ψ治觥6鴮?duì)于椎間融合器,則對(duì)其拉力抵抗力,剪力承受程度和穩(wěn)定性進(jìn)行了實(shí)驗(yàn)和測(cè)試分析。有限元法能夠較好的預(yù)測(cè)螺釘固定和cage的生物力學(xué)特征,其在椎弓根螺釘和融合器的設(shè)計(jì)與分析上得到了廣泛的應(yīng)用。目的:借助有限元分析的方式來研究椎弓根螺釘固定聯(lián)合兩種不同材料cage在L4、5椎間融合中的生物力學(xué)特性。方法:選取自愿參與實(shí)驗(yàn)的健康女性1人,選用螺旋CT掃描方式獲取正常脊柱L4~L5節(jié)段信息,應(yīng)用Mimics和Geomagic軟件對(duì)所采集的掃描圖片信息進(jìn)行立體模型重建,并將此立體模型導(dǎo)入有限元軟件ANSYS15.0進(jìn)而形成L4、5節(jié)段三維有限元模型(INT)。在建立的INT上,再分別建立雙側(cè)椎弓根螺釘聯(lián)合兩種不同材料cage的模型,Mod1為雙側(cè)椎弓根螺釘+Ti(鈦)cage,Mod2為雙側(cè)椎弓根螺釘+PEEK(聚醚醚酮)cage。分別對(duì)兩種立體模型加入500N預(yù)載荷以及8N·m的運(yùn)動(dòng)附加力,對(duì)于立體模型的預(yù)載荷和運(yùn)動(dòng)附加力等約束設(shè)定完成后,在腰椎前屈,后伸,左側(cè)彎、右側(cè)彎及左旋、右旋六種運(yùn)動(dòng)情況下算出L4、5節(jié)段角位移及雙側(cè)椎弓根螺釘和兩種不同融合器所受力。結(jié)果:Mod1,Mod2在6種運(yùn)動(dòng)情況下的角位移均小于正常。受力測(cè)試中,Mod1應(yīng)力最大值在6種運(yùn)動(dòng)情況下均高于Mod2。后伸位時(shí),M1與M2的雙側(cè)椎弓根螺釘及cage的應(yīng)力最大值較其他運(yùn)動(dòng)情況小。結(jié)論:對(duì)于需要融合的節(jié)段,椎弓根螺釘系統(tǒng)可以保證足夠的強(qiáng)度。對(duì)于所需融合節(jié)段在同等穩(wěn)定不變的前提下,PEEK材料的cage應(yīng)力最大值均小于Ti材料的cage,因此,PEEK材料的cage發(fā)現(xiàn)移位及沉降的概率也低于Ti材料的cage,其椎間融合率也相應(yīng)較高。實(shí)驗(yàn)中我們可以發(fā)現(xiàn),在后伸運(yùn)動(dòng)情況下,融合器所受應(yīng)力較小,由此推測(cè)運(yùn)動(dòng)情況下較為穩(wěn)定的為后伸位。
[Abstract]:Background: the development of spinal biomechanics is changing with each passing day, especially in recent years, various new techniques and methods have been developed, pedicle screw fixation and interbody fusion cage (cage) are becoming more and more popular in clinical practice. So that the spinal segment can be stabilized immediately after extensive bone decompression, and through bone grafting to achieve long-term fusion to maintain its normal function. Cage has its own unique advantages, not only increased the fusion rate of vertebral body, reduced the use of bone graft. It can also restore the existing height of intervertebral space, accelerate the fusion rate, and reduce the operation time. Now it has developed into one of the basic techniques of spinal surgery. However, with the increase of the amount of fusion device, there are some examples of fusion failure, such as cage displacement, subsidence and so on. In view of the above failure examples, we have done a lot of experiments and tests on the biomechanical properties of pedicle screw combined with cage [1]. For the pedicle screw experiment, we mainly focus on the analysis of the device anti-fatigue, screw pull-out force and screw force. For interbody fusion cage, the tensile resistance, shear resistance and stability were tested and analyzed. Finite element method can well predict the biomechanical characteristics of screw fixation and cage. It has been widely used in the design and analysis of pedicle screw and fusion cage. Objective: to study the biomechanical characteristics of pedicle screw fixation combined with two different materials cage in L4 / 5 intervertebral fusion by means of finite element analysis (FEM). Methods: a healthy woman who volunteered to participate in the experiment was selected, and the normal spinal L4~L5 segment information was obtained by spiral CT scanning. The scanning images were reconstructed by Mimics and Geomagic software. The three-dimensional model is introduced into the finite element software ANSYS15.0, and then the (INT). Of the L4 / 5 segment 3D finite element model is formed. On the established INT, the model of bilateral pedicle screw combined with two different materials cage was established respectively. The model was Ti (Ti) cage,Mod2 and PEEK (polyether ether ketone) cage.. 500 N preload and 8 N m additional force were added to the two stereoscopic models respectively. After the pre-load and motion additional force of the three-dimensional model were set up, the lumbar vertebrae flexion, extension, left bending, right side bending and left rotation were set. The angular displacement of L4 and 5 segments and the force of bilateral pedicle screws and two different fusion cages were calculated under six right lateral motion conditions. Results the angular displacement of 1: 1 Mod2 was smaller than that of normal under 6 kinds of motion conditions. The maximum stress of Mod1 in stress test is higher than that of Mod2. in 6 kinds of motion conditions. The maximum stress of M 1 and M 2 pedicle screws and cage was smaller than that of other movements. Conclusion: for segments requiring fusion, the pedicle screw system can ensure sufficient strength. The maximum cage stress of peek material is smaller than that of Ti material under the same stable condition. Therefore, the probability of cage finding displacement and settlement of peek material is lower than that of Ti material cage, and the intervertebral fusion rate is also higher. In the experiment, we can find that the stress of the fusion device is small under the condition of the extension motion, so it can be deduced that the stable position of the fusion device is the extension position under the condition of motion.
【學(xué)位授予單位】:青海大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2017
【分類號(hào)】:R687.3

【相似文獻(xiàn)】

相關(guān)期刊論文 前10條

1 王建華;夏虹;尹慶水;吳增暉;李樹林;王善琛;;可注射人工骨融合器的研制及其在微創(chuàng)融合手術(shù)中的初步應(yīng)用[J];臨床骨科雜志;2011年04期

2 郭萍;熊平;;電磁場(chǎng)細(xì)胞融合器的研制[J];醫(yī)學(xué)物理;1991年03期

3 李繼友;李開南;;生物降解可吸收椎體間融合器的研究進(jìn)展[J];中國脊柱脊髓雜志;2009年02期

4 齊保闖;唐輝;范新宇;張美超;朱躍良;李川;徐永清;;四角融合器改良前、后有限元分析對(duì)比研究[J];中國臨床解剖學(xué)雜志;2012年04期

5 莊蘇陽,吳小濤,茅祖斌,洪鑫,王以進(jìn);頸椎前路椎體間微創(chuàng)融合器的生物力學(xué)實(shí)驗(yàn)研究[J];醫(yī)用生物力學(xué);2005年03期

6 張亞峰;楊惠林;唐天駟;史勇;;后路椎體間融合術(shù)后融合器脫出的原因及其翻修術(shù)[J];中國脊柱脊髓雜志;2006年12期

7 張蓓;龔曉;;應(yīng)用新型腰椎融合器行腰椎間融合術(shù)的護(hù)理20例[J];中國實(shí)用護(hù)理雜志;2006年15期

8 張樺;葉曉健;王長(zhǎng)峰;胡玉華;李家順;;單側(cè)關(guān)節(jié)突關(guān)節(jié)切除對(duì)腰椎間融合器長(zhǎng)期融合效果的影響[J];中國組織工程研究與臨床康復(fù);2009年13期

9 陳劍;王賞利;何登偉;;青壯年患者腰椎融合器植入術(shù)后感染的臨床分析[J];中華醫(yī)院感染學(xué)雜志;2013年21期

10 張亞峰,楊惠林,唐天駟,史勇;表面鈦涂層融合器應(yīng)用于腰椎不穩(wěn)癥的初步報(bào)告[J];蘇州大學(xué)學(xué)報(bào)(醫(yī)學(xué)版);2004年04期

相關(guān)會(huì)議論文 前10條

1 何磊;范順武;;與融合器相關(guān)的腰椎翻修術(shù)[A];2006年浙江省骨科學(xué)術(shù)會(huì)議暨浙江省脊柱脊髓學(xué)術(shù)會(huì)議論文匯編[C];2006年

2 趙鳳東;楊偉;范順武;;腰椎TLIF術(shù)后融合器移位及其危險(xiǎn)因素分析[A];2012年浙江省骨科學(xué)術(shù)年會(huì)論文集[C];2012年

3 黃永玲;;TC4鈦合金脊柱融合器的應(yīng)用研究[A];2000年材料科學(xué)與工程新進(jìn)展(上)——2000年中國材料研討會(huì)論文集[C];2000年

4 黃陽亮;劉少喻;梁春祥;李浩淼;于濱生;龍厚清;韓國偉;張旭華;魏富鑫;;Solis融合器治療Ⅱ型及Ⅱa型Hangman骨折——附17例報(bào)告[A];第三屆全國脊髓損傷治療與康復(fù)研討會(huì)論文集[C];2012年

5 張志武;李玢;許文根;;應(yīng)用ROI-C融合器治療頸椎病[A];2013中國工程院科技論壇暨浙江省骨科學(xué)學(xué)術(shù)年會(huì)論文摘要集[C];2013年

6 楊立利;顧一飛;高瑞;袁文;;新型零切跡頸前路融合器治療多節(jié)段頸椎病早期療效研究[A];第十九屆全國中西醫(yī)結(jié)合骨傷科學(xué)術(shù)研討會(huì)論文匯編[C];2012年

7 施培華;方向前;俞杭平;;頸椎鋼板融合器一體化系統(tǒng)(PCB)的臨床應(yīng)用[A];2004年浙江省骨科學(xué)術(shù)會(huì)議論文匯編[C];2004年

8 何永清;張蒲;李華;謝幼專;;PEEK椎體間融合器在頸椎融合中的應(yīng)用(臨床研究)[A];2009年浙江省骨科學(xué)學(xué)術(shù)年會(huì)論文匯編[C];2009年

9 孫元;姜延洲;王珍君;江霞;;JR型脊柱融合器(胸腰椎)的研制與臨床應(yīng)用[A];中國康復(fù)醫(yī)學(xué)會(huì)第四屆會(huì)員代表大會(huì)暨第三屆中國康復(fù)醫(yī)學(xué)學(xué)術(shù)大會(huì)論文匯編[C];2001年

10 李曉林;朱丹杰;金永明;楊迪;陳錦平;;一體化鋼板融合器PCB在頸椎前路的臨床應(yīng)用[A];2009年浙江省骨科學(xué)學(xué)術(shù)年會(huì)論文匯編[C];2009年

相關(guān)重要報(bào)紙文章 前1條

1 曾理;腰椎間微創(chuàng)切口植入傘狀融合器[N];中國醫(yī)藥報(bào);2005年

相關(guān)博士學(xué)位論文 前5條

1 王修文;利用融合器進(jìn)行骶髂關(guān)節(jié)融合的研究[D];山東大學(xué);2010年

2 李軼;PCL-TCP頸椎椎間融合器設(shè)計(jì)制備及動(dòng)物體內(nèi)研究[D];第四軍醫(yī)大學(xué);2014年

3 劉恩志;撐開型融合器治療腰椎疾患長(zhǎng)期隨訪及療效評(píng)價(jià)[D];南方醫(yī)科大學(xué);2014年

4 王甲甲;人體頸椎有限元建模及仿生頸椎椎間融合器研究[D];吉林大學(xué);2014年

5 劉楓;綿羊腰椎植入PA66/n-HA融合器后的初始穩(wěn)定性研究[D];北京協(xié)和醫(yī)學(xué)院;2010年

相關(guān)碩士學(xué)位論文 前10條

1 魏友華;生物降解腰椎小關(guān)節(jié)融合器的設(shè)計(jì)特征及生物力學(xué)實(shí)驗(yàn)研究[D];遵義醫(yī)學(xué)院;2015年

2 張書豪;椎體終板形狀對(duì)融合器表面的數(shù)學(xué)要求[D];鄭州大學(xué);2015年

3 汪濤;成骨化羊ADSCs復(fù)合表面改性融合器構(gòu)建組織工程化骨的研究[D];天津醫(yī)科大學(xué);2015年

4 鄧乾興;經(jīng)椎間孔單節(jié)段腰椎椎間融合術(shù)后融合器下沉的危險(xiǎn)因素及療效分析[D];重慶醫(yī)科大學(xué);2016年

5 郭鑫;應(yīng)用兩種不同材質(zhì)融合器行腰椎椎間融合的三維有限元分析[D];青海大學(xué);2017年

6 洪鑫;后路腰椎椎體間微創(chuàng)融合器的研制及動(dòng)物實(shí)驗(yàn)研究[D];東南大學(xué);2004年

7 何海軍;三種腰椎椎間融合器后路應(yīng)用的比較研究[D];東南大學(xué);2006年

8 張山;可生物降解腰椎橫突間融合器降解過程中生物力學(xué)和影像學(xué)的初步研究[D];遵義醫(yī)學(xué)院;2011年

9 李鵬;可生物降解腰椎橫突間融合器山羊體內(nèi)降解的實(shí)驗(yàn)研究[D];遵義醫(yī)學(xué)院;2012年

10 張曄;計(jì)算機(jī)輔助設(shè)計(jì)腰椎椎間融合器的生物力學(xué)研究[D];第二軍醫(yī)大學(xué);2007年

,

本文編號(hào):2241446

資料下載
論文發(fā)表

本文鏈接:http://sikaile.net/yixuelunwen/waikelunwen/2241446.html


Copyright(c)文論論文網(wǎng)All Rights Reserved | 網(wǎng)站地圖 |

版權(quán)申明:資料由用戶03eb2***提供,本站僅收錄摘要或目錄,作者需要?jiǎng)h除請(qǐng)E-mail郵箱bigeng88@qq.com