C形臂X光機(jī)急性掃描誘導(dǎo)的生物效應(yīng)研究
發(fā)布時(shí)間:2018-05-17 08:05
本文選題:C形臂X光機(jī) + 氧化水平; 參考:《吉林大學(xué)》2015年碩士論文
【摘要】:目前,越來(lái)越多的C形臂X光機(jī)掃描被應(yīng)用到骨科手術(shù)當(dāng)中。雖然C形臂的和患者的健康產(chǎn)生了輻射損害。C形臂X光機(jī)的高頻使用或者濫用導(dǎo)致醫(yī)護(hù)人員和患者受到低劑量電離輻射照射,,累積的電離輻射可能導(dǎo)致受照人群(醫(yī)護(hù)人員、患者和家屬)發(fā)生隨機(jī)性效應(yīng)或確定性效應(yīng)。此外,如何做好C形臂X光機(jī)在術(shù)中的輻射防護(hù)也是放射防護(hù)領(lǐng)域亟需解決和關(guān)注的問(wèn)題。 低劑量電離輻射誘導(dǎo)的效應(yīng)主要包括損傷效應(yīng)和有益效應(yīng),這兩種生物效應(yīng)存在巨大的爭(zhēng)議。低劑量電離輻射誘導(dǎo)的有益效應(yīng)包括興奮性效應(yīng)和適應(yīng)性反應(yīng),而損傷效應(yīng)則包括確定性效應(yīng)和、隨機(jī)性效應(yīng)、旁效應(yīng)、遺傳效應(yīng)和基因組不穩(wěn)定性等。根據(jù)人群流行病學(xué)資料(日本原子彈爆炸幸存者數(shù)據(jù)),低劑量電離輻射誘導(dǎo)的損傷效應(yīng)呈線性無(wú)閾模型,即輻射人群的癌癥風(fēng)險(xiǎn)和與輻射劑量呈線性關(guān)系?茖W(xué)家對(duì)線性無(wú)閾模型(LNT)的主要存在有兩種截然不同的觀點(diǎn),一是線性無(wú)閾模型可能過(guò)高評(píng)估了輻射致癌風(fēng)險(xiǎn),①100mSv-50mSv的輻射劑量不能誘發(fā)顯著的生物效應(yīng);②輻射高本底的研究結(jié)果不能充分證實(shí)輻射損傷效應(yīng);③低劑量電離輻射能誘導(dǎo)有益效應(yīng);④電離輻射導(dǎo)致機(jī)體的DNA損傷,未必一定誘發(fā)癌癥或者惡性腫瘤。二是線性無(wú)閾模型可能低估了電離輻射誘導(dǎo)的癌癥風(fēng)險(xiǎn),①電離輻射可以誘導(dǎo)旁效應(yīng);②存在輻射超敏感人群和基因組不穩(wěn)定性。研究表明C形臂單次掃描或者少量多次掃描均在低劑量電離輻射的范圍內(nèi),低劑量電離輻射誘導(dǎo)的生物效應(yīng)尚且存在較大爭(zhēng)議。所以研究C形臂X光機(jī)輻射誘導(dǎo)的生物效應(yīng)不僅能豐富低劑量電離輻射理論,還能為輻射暴露人群提供相應(yīng)的理論依據(jù)。 目的 研究C形臂X光機(jī)急性掃描對(duì)小鼠機(jī)體的生物效應(yīng) 方法 將健康雄性BALB/c小鼠60只隨即分為對(duì)照組、單次、四次、八次、十二次掃描組,每組12只。對(duì)照組小鼠不掃描,掃描組用C形臂X光機(jī)對(duì)小鼠進(jìn)行全身掃描。用熱釋光劑量計(jì)測(cè)量每個(gè)實(shí)驗(yàn)組小鼠的吸收劑量率。在照射24小時(shí)后,制備并凍存細(xì)胞懸液、血清和小鼠的甲狀腺組織。采用生物化學(xué)方法檢測(cè)小鼠甲狀腺組織中超氧化物歧化酶(SOD)和丙二醛(MDA)的水平;采用酶聯(lián)免疫吸附試驗(yàn)(ELISA)檢測(cè)血清中IL-4和IFN-γ的變化;流式細(xì)胞儀檢測(cè)各照射組小鼠外周血淋巴和骨髓細(xì)胞的凋亡水平。 結(jié)果 1.不同次數(shù)C形臂X光機(jī)掃描對(duì)小鼠甲狀腺組織中MDA水平的影響 甲狀腺組織上清經(jīng)試劑盒檢測(cè)結(jié)果:和對(duì)照組相比,八次和十二次C形臂掃描顯著增加了甲狀腺中MDA的水平,并且MDA的水平在十二次C形臂掃描后達(dá)到頂峰,甲狀腺組織中的MDA水平分別升高了2.39、3.49倍,差異具有統(tǒng)計(jì)學(xué)意義(F=8.31,P0.05)。 2.不同次數(shù)C形臂X光機(jī)掃描誘導(dǎo)的SOD水平變化 甲狀腺組織上清經(jīng)試劑盒檢測(cè)結(jié)果:和對(duì)照組相比,四次、八次和十二次C形臂掃描極大的降低了甲狀腺中的SOD活性,SOD水平分別降低了19.23%、25.80%和27.95%(F=4.61, P0.05)。 3.不同次數(shù)C形臂掃描誘導(dǎo)的血清IFN-γ和IL-4水平 血清經(jīng)ELISA試劑盒檢測(cè)結(jié)果:和對(duì)照組相比,血清IFN-γ和IL-4水平在四次、八次、十二次C形臂掃描后呈下降趨勢(shì),在十二次C形臂掃描后兩者水平達(dá)到最低值,血清IFN-γ和IL-4水平在四次以上掃描后分別降低了14.71%和22.60%、22.99%和44.05%、31.70%和44.43%,差異有統(tǒng)計(jì)學(xué)意義(F=59.26,P0.05); IFN-γ/IL-4比值在不同次數(shù)照射后均無(wú)顯著變化,差異無(wú)統(tǒng)計(jì)學(xué)意義(F=12.47,P0.05)。 4.不同次數(shù)C形臂掃描誘導(dǎo)外周血淋巴細(xì)胞凋亡水平變化 外周血淋巴細(xì)胞經(jīng)流式細(xì)胞儀檢測(cè)結(jié)果:和對(duì)照組相比,八次和十二次C形臂掃描增加了小鼠外周血淋巴細(xì)胞的凋亡水平,凋亡水分別增加了1.68、2.40倍,差異有統(tǒng)計(jì)學(xué)意義(F=23.56,P0.05)。 5.不同次數(shù)C形臂掃描誘導(dǎo)骨髓細(xì)胞的凋亡水平變化 骨髓細(xì)胞經(jīng)流式細(xì)胞儀檢測(cè)結(jié)果:和對(duì)照組相比,十二次C形臂掃描增加了骨髓細(xì)胞的凋亡水平,凋亡水平增加了2.02倍,差異有統(tǒng)計(jì)學(xué)意義(F=19.31,P0.05)。 結(jié)論 C形臂X光機(jī)多次掃描改變了機(jī)體的氧化水平和免疫學(xué)相關(guān)指標(biāo)。另外,機(jī)體通過(guò)啟動(dòng)凋亡來(lái)為維持基因組穩(wěn)定性。
[Abstract]:At present , more and more C - arm X - ray machine scanning has been applied to orthopedic surgery . Although C - arm and patient ' s health produce radiation damage , high - frequency use or abuse of C - arm X - ray machine can lead to random or deterministic effects of medical personnel and patients with low - dose ionizing radiation . Furthermore , how to do well the radiation protection of C - arm X - ray machine in operation is a problem that needs to be solved and cared for in radiation protection field .
The effects of low - dose ionizing radiation mainly include damage effect and beneficial effect , and the two biological effects are controversial . The beneficial effects induced by low - dose ionizing radiation include excitatory effect and adaptive response , but the damage effects include deterministic effects , random effects , side effects , genetic effects and genomic instability .
( 2 ) The results of high radiation background can not fully confirm the effect of radiation damage ;
( 3 ) Low - dose ionizing radiation can induce beneficial effects ;
( 4 ) Ionizing radiation leads to DNA damage in the organism , which may not necessarily induce cancer or malignancy . Second , the linear non - threshold model may underestimate the risk of ionizing radiation - induced cancer , and ( 1 ) ionizing radiation can induce side effects ;
The results show that the biological effects induced by low dose ionizing radiation are not only rich in low dose ionizing radiation , but also can provide theoretical basis for radiation exposure .
Purpose
Study on the Biological Effects of Acute Scan of C - arm X - ray Machine on Mice
method
Sixty healthy male BALB / c mice were randomly divided into two groups : control group , single , four , eight , and ten second scanning groups , 12 in each group . The control group mice did not scan , the scanning group scanned the mice with C - arm X - ray machine . After 24 hours of irradiation , the cells were prepared and frozen . The levels of superoxide dismutase ( SOD ) and malondialdehyde ( MDA ) in thyroid tissues of mice were detected by biochemical method .
ELISA was used to detect the changes of IL - 4 and IFN - 緯 in serum .
Flow cytometry was used to detect the level of apoptosis in peripheral blood lymphocytes and bone marrow cells of irradiated mice .
Results
Effect of different times of C - arm X - ray machine scanning on the level of MDA in thyroid tissue of mice
Results : Compared with the control group , the levels of MDA in the thyroid were significantly increased compared with the control group , and the level of MDA increased 2.39 , 3.49 times higher than that in the thyroid tissues ( F = 8.31 , P0.05 ) .
2 . Changes of SOD level induced by X - ray machine scanning at different times
Results : Compared with the control group , four , eight and ten C - arm scans significantly decreased the SOD activity in the thyroid , and the SOD level decreased by 19.23 % , 25.80 % and 27.95 % ( F = 4.61 , P0.05 ) .
3 . Serum IFN - 緯 and IL - 4 levels induced by C - arm scans at different times
The levels of IFN - 緯 and IL - 4 decreased by 14.71 % and 22.60 % , 22.99 % and 44.05 % , 31.70 % and 44.43 % , respectively .
4 . Changes of apoptosis in peripheral blood lymphocytes induced by C - arm scans of different times
Compared with the control group , eight and ten C - arm scans increased the level of apoptosis in peripheral blood lymphocytes of mice , and the apoptotic water increased by 1 . 68 and 2 . 40 times , respectively ( F = 23.56 , P0.05 ) .
5 . Changes of apoptosis in bone marrow cells induced by C - arm scans of different times
Compared with the control group , the apoptosis level of bone marrow cells increased by 2 . 02 times , and the difference was statistically significant ( F = 19.31 , P0.05 ) .
Conclusion
C - arm X - ray machine multiple scans have changed the body ' s oxidation level and immunological correlation index . In addition , the organism can maintain genome stability by initiating apoptosis .
【學(xué)位授予單位】:吉林大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2015
【分類號(hào)】:R687
【參考文獻(xiàn)】
相關(guān)期刊論文 前4條
1 賈建軍;王自能;劉革修;王志新;;腫瘤浸潤(rùn)性樹(shù)突狀細(xì)胞在子宮內(nèi)膜癌中的凋亡及其Fas、FasL表達(dá)意義[J];南方醫(yī)科大學(xué)學(xué)報(bào);2011年10期
2 劉樹(shù)錚;;低水平輻射致癌效應(yīng)的閾值問(wèn)題[J];輻射防護(hù);2008年06期
3 王小玲;;術(shù)中使用C型臂X線機(jī)電離輻射的防護(hù)[J];河南外科學(xué)雜志;2008年06期
4 劉相花;白玫;劉彬;;C型臂CT成像有效劑量估算及新舊ICRP建議書差異比較[J];介入放射學(xué)雜志;2010年10期
本文編號(hào):1900605
本文鏈接:http://sikaile.net/yixuelunwen/waikelunwen/1900605.html