天堂国产午夜亚洲专区-少妇人妻综合久久蜜臀-国产成人户外露出视频在线-国产91传媒一区二区三区

血球儀數(shù)字化關鍵技術研究

發(fā)布時間:2019-05-15 20:45
【摘要】:現(xiàn)代醫(yī)學中,血球儀能迅速檢測人體血液的主要成分,在臨床醫(yī)療中占據(jù)了重要地位。國內早期的血球儀受到當時條件限制,基本采用模擬電路來識別血細胞信號,該方法無法識別較復雜信號從而產生漏計或錯計。此外采用模擬電路識別血細胞信號,電路體積龐大、調試困難、電路參數(shù)易受到環(huán)境等因素影響,導致識別統(tǒng)計變得不準確。隨著集成電路、EDA技術的發(fā)展,數(shù)字技術在社會生產各方面得到了越來越廣泛的應用。數(shù)字化檢測方法不易受電源等因素的干擾,且可以識別復雜信號,電路簡單且穩(wěn)定。采用數(shù)字化的方法對血細胞信號檢測無疑是解決以上問題的最佳途徑之一。 本文針對血球儀數(shù)字化得需求,通過對血細胞信號分析,提出一種易于在FPGA中實現(xiàn)的狀態(tài)分析識別算法,采用該方法在Cyclone II系列FPGA(EP2C35)中完成了三通道血細胞分析裝置設計。在此基礎上,采用SOPC技術將Nios II處理器、LCD控制器、血細胞識別裝置等功能模塊在單片F(xiàn)PGA中實現(xiàn),減少了血液分析儀的電路板體積并降低了實現(xiàn)成本,同時提高了血球儀識別統(tǒng)計的性能。另外設計了高速數(shù)據(jù)采集電路、四線電阻式觸摸屏控制器、血細胞信號發(fā)生器等構成整個血液分析硬件平臺。在Nios II集成開發(fā)環(huán)境下采用小巧實用的μC/OS-II實時操作系統(tǒng)和用戶圖形界面μC/GUI完成血液分析人機交互系統(tǒng),并在該人機交互系統(tǒng)中完成了整個應用程序的設計。 最后,采用質控血和血細胞信號發(fā)生器對血球儀的重復性與線性度這兩項關鍵指標進行測試,測試結果表明本血球儀在這兩項指標上均滿足《血液分析儀國家醫(yī)藥行業(yè)標準》中的要求,,可以用于臨床醫(yī)學診斷。
[Abstract]:In modern medicine, blood cell meter can quickly detect the main components of human blood, and occupies an important position in clinical medicine. The early blood cell instrument in China was limited by the conditions at that time, and the analog circuit was basically used to identify the blood cell signal. This method can not identify the more complex signal, resulting in leakage or miscalculation. In addition, the analog circuit is used to identify the blood cell signal, the circuit volume is large, the debugging is difficult, and the circuit parameters are easily affected by the environment, which leads to the inaccurate recognition statistics. With the development of integrated circuit and EDA technology, digital technology has been more and more widely used in all aspects of social production. The digital detection method is not easily interfered by power supply and can identify complex signals. The circuit is simple and stable. Digital detection of blood cell signal is undoubtedly one of the best ways to solve the above problems. In this paper, according to the requirement of digital blood cell instrument, through the analysis of blood cell signal, a state analysis and recognition algorithm which is easy to be realized in FPGA is proposed, and the design of three-channel blood cell analysis device is completed in Cyclone II series FPGA (EP2C35). On this basis, the Nios II processor, LCD controller, blood cell recognition device and other functional modules are realized in a single FPGA by using SOPC technology, which reduces the circuit board volume of the blood analyzer and reduces the implementation cost. At the same time, the performance of blood cell meter recognition and statistics is improved. In addition, the high speed data acquisition circuit, four-wire resistance touch screen controller and blood cell signal generator are designed to form the whole hardware platform of blood analysis. In the integrated development environment of Nios II, the human-computer interaction system of blood analysis is completed by using the small and practical 渭 C/OS-II real-time operating system and user graphical interface 渭 C/GUI, and the whole application program is designed in the human-computer interaction system. Finally, the reproducibility and linearity of the blood cell instrument were tested by using the quality control blood and blood cell signal generator. The results show that the blood cell instrument meets the requirements of the National Pharmaceutical Industry Standard of Blood Analyser on these two indexes and can be used for clinical medical diagnosis.
【學位授予單位】:寧波大學
【學位級別】:碩士
【學位授予年份】:2012
【分類號】:TH776;R318.6

【參考文獻】

相關期刊論文 前10條

1 張耀麒;;應用于電阻式觸摸屏的ADS7846控制器[J];電子科技;2006年09期

2 汪廷華;夏斌;楊文璐;秦振華;;μC/GUI在Nios Ⅱ嵌入式平臺上的移植研究[J];電子設計工程;2010年09期

3 賈丹丹;李宏;;基于神經網(wǎng)絡和小波分析的血細胞識別算法[J];計算機應用與軟件;2009年08期

4 趙蕾;唐曉英;顏簫;;血細胞分析儀質控物的初步研究[J];生命科學儀器;2007年03期

5 李延斌,逄天秋;血液分析儀[J];世界最新醫(yī)學信息文摘;2004年06期

6 吳燦;;解讀白細胞體積分布圖及白細胞分類的臨床意義[J];實用醫(yī)技雜志;2006年10期

7 王選民;李明利;張利川;張曉博;;基于ADS7846的電阻式觸摸屏接口設計[J];現(xiàn)代電子技術;2010年11期

8 吳凌燕;蘇建元;吳天靜;;觸摸屏按鍵處理方法研究[J];儀表技術;2008年10期

9 吳凌燕;陳世夏;丁國臣;;基于C8051F020的液晶顯示應用研究[J];儀表技術;2009年01期

10 陳俊梅,周為;血液分析儀技術的原理與應用[J];醫(yī)療設備信息;2002年10期

相關碩士學位論文 前9條

1 崔海逢;基于FPGA的GPS中頻數(shù)據(jù)采集及網(wǎng)絡傳輸系統(tǒng)設計[D];南京航空航天大學;2009年

2 許志偉;自動血細胞計數(shù)器技術的研究[D];中國人民解放軍軍事醫(yī)學科學院;2004年

3 湯學民;血液細胞圖像自動識別系統(tǒng)的開發(fā)[D];清華大學;2004年

4 陳寶基;嵌入式實時操作系統(tǒng)uC/OS-Ⅱ應用開發(fā)研究[D];山東大學;2005年

5 曾萍萍;人體血液白細胞五分類數(shù)字圖像處理系統(tǒng)[D];南昌大學;2006年

6 周進;μC/GUI在基于Nios的嵌入式系統(tǒng)中的研究與實現(xiàn)[D];南京理工大學;2006年

7 吳義滿;血細胞分析技術研究[D];電子科技大學;2008年

8 劉鯉f^;嵌入式圖形用戶界面的研究與實現(xiàn)[D];武漢理工大學;2009年

9 劉念;基于μC/OS-II的嵌入式電子點餐系統(tǒng)的設計[D];武漢理工大學;2010年



本文編號:2477744