Tosight喉鏡用于新生兒氣管插管時七氟醚吸入肺泡氣濃度
發(fā)布時間:2018-01-24 13:40
本文關(guān)鍵詞: Tosight喉鏡 七氟醚 新生兒 改良序貫法 出處:《首都醫(yī)科大學學報》2015年03期 論文類型:期刊論文
【摘要】:目的測定新生兒Tosight喉鏡氣管插管時七氟醚吸入的半數(shù)肺泡氣濃度(minimum alveolar concentrations effective inhaled concentrations in 50%,MAC EI_(50))和95%有效肺泡氣濃度(minimum alveolar concentrations effective inhaled concentrations in95%,MAC EI_(50))。方法選擇22例美國麻醉醫(yī)師協(xié)會(American Society of Anesthesiologists,ASA)1或Ⅱ級擇期全身麻醉手術(shù)的新生兒,吸入七氟醚麻醉,初次濃度設置為3.3%,相鄰濃度比為1.1,七氟醚的濃度按改良序貫法增加或減少一級,待七氟醚的濃度達血一腦平衡10 min后行氣管插管。用概率單位回歸法計算出新生兒Tosight喉鏡氣管插管時七氟醚吸入誘導的肺泡氣濃度MAC EI_(50)和EI_(95)及相應的95%可信區(qū)間(confidence interval,95%CI)。結(jié)果全憑七氟醚吸入誘導Tosight喉鏡氣管插管時患兒肺泡氣濃度的MAC EI_(50)為3.65%,95%CI為3.28%~4.04%;MAC EI_(95)為4.24%,95%CI為3.93%~7.14%。結(jié)論 Tosight喉鏡用于新生兒氣管插管時的肺泡氣濃度的MAC EI_(50)和EI_(95)分別為3.65%和4.24%。
[Abstract]:Objective to determine the concentration of 50% alveolar gas inhaled by sevoflurane during tracheal intubation under laryngoscope in neonates with Tosight. Minimum alveolar concentrations effective inhaled concentrations in. 50%. MAC EI (50) and 95% effective alveolar gas concentrations (. Minimum alveolar concentrations effective inhaled concentrations. In95%. Methods 22 cases of American Society of Anesthesiologists were selected. The primary concentration of sevoflurane in the neonates undergoing elective general anesthesia of ASA)1 or grade II was 3.3 and the ratio of adjacent concentration was 1.1. The concentration of sevoflurane was increased or decreased by the improved sequential method. Once the concentration of sevoflurane reaches the blood-brain balance 10. Tracheal intubation was performed after min. The concentration of alveolar gas induced by sevoflurane inhalation was calculated by using probabilistic unit regression method in neonatal Tosight laryngoscopic tracheal intubation. (. And the corresponding 95% confidence interval confidence interval. Results the concentration of alveolar gas in children with Tosight tracheal intubation induced by sevoflurane inhalation was 3.65%. 95 CI 3.28 and 4.04; MAC EIJ 95) is 4.24%. Conclusion Tosight laryngoscope is used for the concentration of alveolar gas in neonates during tracheal intubation. 3.65% and 4.24, respectively.
【作者單位】: 首都醫(yī)科大學附屬北京兒童醫(yī)院麻醉科;
【分類號】:R726.1
【正文快照】: Tosight視頻喉鏡是一種便捷可靠的新型國產(chǎn)喉和95%有效肺泡氣濃度(minimum alveolar concentra-鏡,它的優(yōu)勢是不需要口、咽和喉三軸線重合就可以 tions effective inhaled concentrations in 95%,MAC良好的暴露聲門,理論上更適用于不易暴露聲門的新 EI95),為臨床提供參考。生
【參考文獻】
相關(guān)期刊論文 前4條
1 胡t,
本文編號:1460175
本文鏈接:http://sikaile.net/yixuelunwen/mazuiyixuelunwen/1460175.html
最近更新
教材專著