不同清洗條件下反滲透系統(tǒng)清洗效果的對比分析
發(fā)布時間:2018-08-29 11:01
【摘要】:伴隨著生產和生活產生的排水,市政污水和工業(yè)廢水越來越多的成為了膜法水處理的給水。隨著反滲透膜在市政污水回用領域的廣泛應用,膜系統(tǒng)污染的問題日益突出,通常系統(tǒng)污染表現為進水壓力升高、段間壓差增大和產水量下降等現象。當污染物積累到一定程度就需要對系統(tǒng)進行清洗,通過對再生水廠反滲透系統(tǒng)污染物的分析,其中有機物占77%,無機鹽占23%,有機物和微生物污染較為嚴重。通過對不同清洗條件下,系統(tǒng)清洗效果的分析,可以得出在保持清洗時間為15h、清洗溫度為30℃時,去除反滲透系統(tǒng)有機物和微生物污染較為有效的藥液配置是0.025%Na—SDS加0.1%NaOH組成的堿性清洗液,去除碳酸鹽垢有效的清洗藥液配置為0.2%HCl的酸性清洗液,在該清洗條件下反滲透系統(tǒng)清洗后進水壓力和段間壓差降低顯著。
[Abstract]:With the production and life of sewage, municipal sewage and industrial wastewater has become more and more membrane water treatment water supply. With the wide application of reverse osmosis membrane in municipal wastewater reuse, the problem of membrane system fouling is becoming more and more serious. Usually, the system pollution is characterized by the increase of influent pressure, the increase of pressure difference between sections and the decrease of water production. It is necessary to clean the system when the pollutants accumulate to a certain extent. Through the analysis of pollutants in the reverse osmosis system of the recycling water plant, the organic matter is 77%, the inorganic salt is 2330%, the organic matter and microorganism pollution is more serious. By analyzing the cleaning effect of the system under different cleaning conditions, it can be concluded that when the cleaning time is 15 hours and the cleaning temperature is 30 鈩,
本文編號:2211005
[Abstract]:With the production and life of sewage, municipal sewage and industrial wastewater has become more and more membrane water treatment water supply. With the wide application of reverse osmosis membrane in municipal wastewater reuse, the problem of membrane system fouling is becoming more and more serious. Usually, the system pollution is characterized by the increase of influent pressure, the increase of pressure difference between sections and the decrease of water production. It is necessary to clean the system when the pollutants accumulate to a certain extent. Through the analysis of pollutants in the reverse osmosis system of the recycling water plant, the organic matter is 77%, the inorganic salt is 2330%, the organic matter and microorganism pollution is more serious. By analyzing the cleaning effect of the system under different cleaning conditions, it can be concluded that when the cleaning time is 15 hours and the cleaning temperature is 30 鈩,
本文編號:2211005
本文鏈接:http://sikaile.net/shengtaihuanjingbaohulunwen/2211005.html
最近更新
教材專著