基于變量程階梯式加藥的COD檢測(cè)系統(tǒng)研究
本文選題:COD檢測(cè) + 階梯式加藥 ; 參考:《江蘇大學(xué)》2017年碩士論文
【摘要】:隨著經(jīng)濟(jì)的高速發(fā)展與工業(yè)化進(jìn)程加速,排出的生活與工業(yè)污水?dāng)?shù)量也持續(xù)增多,導(dǎo)致水質(zhì)惡化程度加大,對(duì)水資源的可持續(xù)利用造成不利影響。因此,對(duì)水質(zhì)污染指標(biāo)的有效檢測(cè)與監(jiān)控迫在眉睫。化學(xué)需氧量(COD)是評(píng)價(jià)水體污染程度的重要指標(biāo)之一。目前COD檢測(cè)方法中普遍使用重鉻酸鉀作為氧化劑,而重鉻酸鉀是一種有毒且能夠致癌的物質(zhì)。常用的COD檢測(cè)系統(tǒng)都是通過一次性添加過量重鉻酸鉀進(jìn)行COD消解檢測(cè)操作,而一次性加藥方式容易造成用藥量浪費(fèi)與二次污染。因此研究一套能夠控制重鉻酸鉀用量的COD檢測(cè)系統(tǒng)具有重要意義。通過對(duì)國內(nèi)外常用COD檢測(cè)系統(tǒng)的分析,研究一種基于變量程階梯式加藥的COD檢測(cè)系統(tǒng)。論文主要研究內(nèi)容如下:(1)針對(duì)當(dāng)前COD檢測(cè)系統(tǒng)對(duì)重鉻酸鉀的粗放使用,提出了一種COD檢測(cè)階梯式加藥方法,有效地控制了重鉻酸鉀的用量,避免藥劑浪費(fèi)和減少二次污染。(2)針對(duì)階梯加藥過程中存在的分段加藥與分段消解兩個(gè)關(guān)鍵步驟,在理論分析基礎(chǔ)上,研究一種階梯式加藥具體實(shí)現(xiàn)方法。(3)搭建COD現(xiàn)場(chǎng)檢測(cè)系統(tǒng)的實(shí)驗(yàn)平臺(tái),完成相關(guān)軟硬件設(shè)計(jì)。硬件電路主要包括:光電檢測(cè)、溫度檢測(cè)與加熱驅(qū)動(dòng)、電機(jī)驅(qū)動(dòng)與閥門開關(guān)控制以及微處理器與A/D等單元;軟件部分主要包括:量程切換、PID恒溫控制以及A/D單元數(shù)據(jù)傳輸?shù)取?4)設(shè)計(jì)COD檢測(cè)數(shù)據(jù)的遠(yuǎn)程監(jiān)測(cè)系統(tǒng),主要包括無線收發(fā)單元與上位機(jī)監(jiān)控軟件,可以實(shí)現(xiàn)數(shù)據(jù)的遠(yuǎn)程實(shí)時(shí)顯示、存儲(chǔ)以及查詢等功能。(5)在搭建的實(shí)驗(yàn)平臺(tái)上,完成相關(guān)實(shí)驗(yàn),并進(jìn)行藥劑節(jié)省與系統(tǒng)性能分析。實(shí)驗(yàn)結(jié)果表明:系統(tǒng)既能夠準(zhǔn)確可靠地檢測(cè)出待測(cè)水樣COD值,同時(shí)又能夠有效降低重鉻酸鉀使用量,尤其在低濃度COD水樣檢測(cè)實(shí)驗(yàn)中,與一次性加藥實(shí)驗(yàn)相比,所加藥劑節(jié)省量約為40%,大大減少了二次污染。
[Abstract]:With the rapid development of economy and the acceleration of industrialization, the amount of domestic and industrial sewage discharged continues to increase, which leads to the deterioration of water quality, which has a negative impact on the sustainable utilization of water resources. Therefore, the effective detection and monitoring of water pollution index is urgent. Chemical oxygen demand (COD) is one of the important indexes to evaluate water pollution. Potassium dichromate is widely used as oxidant in COD detection methods. Potassium dichromate is a toxic and carcinogenic substance. The commonly used COD detection system is to remove COD by adding excessive potassium dichromate at one time, and the one-time dosing method is easy to cause waste of dosage and secondary pollution. Therefore, it is of great significance to study a COD detection system which can control the amount of potassium dichromate. Based on the analysis of common COD detection systems at home and abroad, a COD detection system based on variable step dosing was studied. The main contents of this paper are as follows: (1) in view of the extensive use of current COD detection system to potassium dichromate, a step type method for COD detection is proposed, which effectively controls the amount of potassium dichromate. To avoid the waste and reduce the secondary pollution. (2) aiming at the two key steps of step adding and segmental digestion, based on the theoretical analysis, In this paper, a step by step dosing method is studied to build the experimental platform of COD field detection system, and complete the related software and hardware design. The hardware circuit mainly includes: photoelectric detection, temperature detection and heating drive, motor drive and valve switch control, microprocessor and A / D unit. The software part mainly includes: range switching pid constant temperature control and A / D unit data transmission etc.) the design of COD detection data remote monitoring system, mainly including wireless transceiver unit and host computer monitoring software, can realize the remote real-time display of data. Storage and query functions. 5) on the experimental platform, complete the related experiments, and carry out the pharmaceutical saving and system performance analysis. The experimental results show that the system can not only accurately and reliably detect the COD value of the water sample to be measured, but also effectively reduce the amount of potassium dichromate, especially in the low concentration COD water sample detection experiment, compared with the one-off experiment. The added medicine saves about 40%, greatly reducing the secondary pollution.
【學(xué)位授予單位】:江蘇大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2017
【分類號(hào)】:X703
【參考文獻(xiàn)】
相關(guān)期刊論文 前10條
1 丁佳;;COD測(cè)定儀法測(cè)定不同水樣COD消解時(shí)間的差異性[J];環(huán)境監(jiān)控與預(yù)警;2015年06期
2 黃麗詩;;哈希測(cè)定儀COD_(Cr)分析方法的消解時(shí)間研究與優(yōu)化[J];廣東化工;2015年07期
3 嚴(yán)長城;應(yīng)貴平;;基于PT100鉑熱電阻的高精度測(cè)溫系統(tǒng)的設(shè)計(jì)[J];機(jī)電工程技術(shù);2015年03期
4 宋開棟;丁立利;李曉康;段宗科;楊增萬;寇明杰;張得儉;;鋼帶式果蔬干燥設(shè)備溫度控制系統(tǒng)設(shè)計(jì)及優(yōu)化[J];機(jī)械研究與應(yīng)用;2015年01期
5 羅國兵;;水體化學(xué)需氧量的檢測(cè)方法[J];巖礦測(cè)試;2013年06期
6 鄭培超;于斌;劉克銘;代玉;王金梅;;硅光二極管光電檢測(cè)電路的研究與設(shè)計(jì)[J];重慶郵電大學(xué)學(xué)報(bào)(自然科學(xué)版);2013年04期
7 薛云偉;;朗伯-比爾定律和光[J];產(chǎn)業(yè)與科技論壇;2013年13期
8 涂建坤;徐曉鋒;董輝平;;小型恒溫箱系統(tǒng)的設(shè)計(jì)與應(yīng)用[J];電子世界;2012年22期
9 王俊;唐啟;崔俊峰;張富強(qiáng);王秋菊;;重鉻酸鉀法測(cè)定水中化學(xué)需氧量的分析研究[J];河南科學(xué);2012年09期
10 付春艷;;基于PID控制算法的爐溫恒溫控制系統(tǒng)的設(shè)計(jì)[J];電腦知識(shí)與技術(shù);2011年27期
相關(guān)博士學(xué)位論文 前1條
1 張?jiān)?計(jì)算滴定分析法的理論及應(yīng)用[D];同濟(jì)大學(xué);2008年
相關(guān)碩士學(xué)位論文 前8條
1 王小格;基于WSN的循環(huán)水養(yǎng)殖多參數(shù)巡回監(jiān)控系統(tǒng)研制[D];江蘇大學(xué);2016年
2 范路曼;分光光度法COD檢測(cè)儀研制[D];西安電子科技大學(xué);2014年
3 理康;加速試驗(yàn)溫度控制系統(tǒng)研究[D];中北大學(xué);2013年
4 陳維維;污水COD近紅外光譜定量分析的模型研究[D];暨南大學(xué);2011年
5 劉國新;基于Si4432的無線傳輸系統(tǒng)設(shè)計(jì)[D];大連理工大學(xué);2010年
6 王立婷;光電檢測(cè)電路的設(shè)計(jì)及實(shí)驗(yàn)研究[D];吉林大學(xué);2007年
7 董琳;城市居民生活用水的階梯式計(jì)量水價(jià)研究[D];西安理工大學(xué);2007年
8 孫長嵩;基于機(jī)器學(xué)習(xí)的水質(zhì)COD測(cè)量方法研究[D];浙江大學(xué);2006年
,本文編號(hào):2011538
本文鏈接:http://sikaile.net/shengtaihuanjingbaohulunwen/2011538.html