風腔厚度對強迫風冷系統(tǒng)散熱性能的影響
發(fā)布時間:2018-04-19 18:26
本文選題:雷達 + 強迫風冷。 參考:《雷達科學與技術(shù)》2017年02期
【摘要】:以某雷達天線單元為研究對象,采用Icepak熱仿真軟件,研究了風腔厚度對強迫風冷系統(tǒng)散熱性能的影響。結(jié)果表明:風腔厚度對風冷系統(tǒng)的散熱性能有明顯影響;保持風機型號和散熱器結(jié)構(gòu)不變,當風腔厚度過小時,風機的性能受到明顯抑制;隨著風腔厚度的增加,風機的性能會變好,發(fā)熱元件的溫度明顯降低;當風腔厚度達到一定值后再繼續(xù)增加時,風機的性能反而會下降,發(fā)熱元件的溫度也相應(yīng)升高。在工程設(shè)計中,推薦此類風冷散熱結(jié)構(gòu)的風腔厚度取值不小于16mm,不大于40mm。
[Abstract]:Taking a radar antenna unit as the research object, the effect of the thickness of the air chamber on the heat dissipation performance of the forced air cooling system is studied by using the Icepak thermal simulation software.The results show that the thickness of the air chamber has a significant effect on the cooling performance of the air cooling system, while keeping the type of fan and the structure of the radiator unchanged, when the thickness of the air chamber is too small, the performance of the fan is obviously suppressed; with the increase of the thickness of the air chamber,The performance of the fan will become better and the temperature of the heating element will obviously decrease, and when the thickness of the air chamber reaches a certain value and then continues to increase, the performance of the fan will decrease and the temperature of the heating element will rise accordingly.In the engineering design, it is recommended that the thickness of the air chamber of this kind of air-cooled heat dissipation structure is not less than 16mm and not more than 40mm.
【作者單位】: 中國電子科技集團公司第三十八研究所;
【分類號】:TN957
【相似文獻】
相關(guān)期刊論文 前2條
1 王飛朝;;搜索雷達機箱的動平衡及強迫風冷熱特性測試[J];機械;2011年S1期
2 ;[J];;年期
相關(guān)會議論文 前1條
1 袁玲;;信號處理機柜的強迫風冷設(shè)計[A];中國電子學會電子機械工程分會2009年機械電子學學術(shù)會議論文集[C];2009年
,本文編號:1774216
本文鏈接:http://sikaile.net/kejilunwen/xinxigongchenglunwen/1774216.html
最近更新
教材專著