中美建筑通風(fēng)系統(tǒng)標(biāo)準(zhǔn)對(duì)比及自然通風(fēng)應(yīng)用效果分析
[Abstract]:With the rapid development of the construction industry, the energy and environmental crisis caused by it has become a reality that the public have to face, thus causing the building energy conservation and green building boom. In recent years, the level of social material economy has also been significantly improved, people's living standards have been greatly improved, and the requirements for the working life of the building interior environment are also gradually raised. Natural ventilation is an important means of building energy saving and improving indoor air quality. Therefore, how to design and apply natural ventilation in architecture is an important research direction to realize building energy saving, green building and meet the requirements of personnel comfort. There is no specific standard guide for the application of natural ventilation in China. The (ASHRAE) standard system of American Association of heating, Refrigeration and Air-conditioning Engineers has more perfect standards and specifications on ventilation system and natural ventilation. Therefore, this paper first compares the relevant standards and specifications of the building ventilation system between China and the United States, and makes a detailed comparison of the ventilation system standard system and the relevant specific requirements of the ventilation system, and draws the main differences between the two countries' ventilation system standards. And put forward the relevant suggestion that our country standard draws lessons from. Based on the main differences between the design standards of the two countries, and in view of the detailed comparison of the effects of natural ventilation on the improvement of indoor environment comfort in the standards of the two countries, it is found that there are different models for evaluating the comfort range between the two countries. Therefore, two different evaluation systems are used to calculate and compare the indoor temperature in the two environments of Chongqing office building air conditioning operation mode and free operation mode, and the thermal comfort degree of different indoor environment. Through the investigation of the buildings in Chongqing, it is concluded that the actual wind speed and the expected wind speed in the natural ventilation buildings are higher than those in the air-conditioned buildings, so the wind speed compensation for the free-running buildings is carried out according to the wind speed values obtained from the investigation. By using the thermal comfort evaluation calculation method, the thermal comfort temperature range of two operation modes is obtained, and the operating mode of the whole air-conditioning system of Chongqing office building under different comfort levels and different natural ventilation strategies is set up. The temperature conversion values of six working conditions, such as mixed ventilation operation mode and night ventilation operation mode, are alternately used in natural ventilation and air conditioning system. The energy consumption under each working condition is calculated by energy consumption simulation software DesignBuilder. The energy saving effect can be achieved by using natural ventilation in office buildings in Chongqing. The results show that the range of comfort is affected by different indoor wind speed in natural ventilation environment and has a wider adaptive comfort range in natural ventilation environment than in air conditioning environment. On the basis of ensuring comfort, the energy saving effect can be achieved by using the mixed operation mode of natural ventilation and night ventilation, and the energy saving rate can reach about 15%. The energy saving rate of day or night ventilation alone is basically the same, and the indoor environment with day and night natural ventilation at the same energy consumption level can achieve higher comfort. It also shows that natural ventilation can improve the indoor environment obviously. Therefore, setting a reasonable natural ventilation strategy in Chongqing office buildings can achieve the dual effect of comfort and energy saving. This research method can also be used in different types of buildings in different climatic regions. The results can provide theoretical basis for perfecting the technical application standard of ventilation system in China.
【學(xué)位授予單位】:重慶大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2013
【分類號(hào)】:TU834
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 張漢民;;論濕熱地區(qū)住宅的通風(fēng)[J];新建筑;1993年03期
2 龔明啟,冀兆良,蘇宇貴;夏熱冬暖地區(qū)自然通風(fēng)條件下圍護(hù)結(jié)構(gòu)內(nèi)壁溫度的計(jì)算與分析[J];墻材革新與建筑節(jié)能;2004年11期
3 張金萍,李安桂;自然通風(fēng)的研究應(yīng)用現(xiàn)狀與問題探討[J];暖通空調(diào);2005年08期
4 王怡;劉加平;肖勇強(qiáng);;自然通風(fēng)房間熱環(huán)境的耦合模擬計(jì)算方法[J];太陽能學(xué)報(bào);2006年01期
5 田永英;舒平;;上海軍械大廈的設(shè)計(jì)分析[J];山西建筑;2006年20期
6 馮慧;李安桂;;高層建筑樓梯間煙囪效應(yīng)實(shí)測(cè)分析[J];山西建筑;2007年12期
7 孟慶林;高云飛;;萬科建筑研究中心大廳自然通風(fēng)分析[J];暖通空調(diào);2007年08期
8 王怡;姚海兵;文福;陳靖;;建筑開口率對(duì)自然通風(fēng)流量系數(shù)的影響分析[J];工業(yè)建筑;2008年S1期
9 區(qū)慧美;;自然通風(fēng)在高層住宅設(shè)計(jì)中的應(yīng)用[J];科技資訊;2009年17期
10 王洪光;邱巍;;以西安地區(qū)為例談自然通風(fēng)在教學(xué)建筑中的應(yīng)用[J];重慶建筑;2009年06期
相關(guān)會(huì)議論文 前10條
1 段雙平;;熱壓自然通風(fēng)與機(jī)械通風(fēng)共存的大開口建筑多元通風(fēng)[A];全國暖通空調(diào)制冷2010年學(xué)術(shù)年會(huì)資料集[C];2010年
2 譚剛;左會(huì)剛;李曉鋒;朱穎心;;自然通風(fēng)的理論機(jī)理分析與實(shí)驗(yàn)驗(yàn)證[A];全國暖通空調(diào)制冷1998年學(xué)術(shù)文集[C];1998年
3 譚剛;朱穎心;李曉鋒;;熱壓自然通風(fēng)的實(shí)驗(yàn)研究與數(shù)值模擬[A];全國暖通空調(diào)制冷2000年學(xué)術(shù)年會(huì)論文集[C];2000年
4 李曉鋒;譚剛;朱穎心;;自然通風(fēng)設(shè)計(jì)方法研究(一)理論與方法[A];全國暖通空調(diào)制冷2000年學(xué)術(shù)年會(huì)資料集[C];2000年
5 李曉鋒;譚剛;朱穎心;;自然通風(fēng)設(shè)計(jì)方法研究(二)應(yīng)用實(shí)例[A];全國暖通空調(diào)制冷2000年學(xué)術(shù)年會(huì)資料集[C];2000年
6 黃艷;劉東;楊建坤;張恩澤;;某雙層玻璃幕墻建筑自然通風(fēng)的數(shù)值模擬研究[A];全國暖通空調(diào)制冷2004年學(xué)術(shù)年會(huì)資料摘要集(2)[C];2004年
7 陳芳達(dá);代欽;;房屋自然通風(fēng)的風(fēng)洞實(shí)驗(yàn)與PIV流場(chǎng)測(cè)量[A];第八屆全國實(shí)驗(yàn)流體力學(xué)學(xué)術(shù)會(huì)議論文集[C];2010年
8 應(yīng)柏平;;變壓器室自然通風(fēng)研究[A];全國暖通空調(diào)制冷2000年學(xué)術(shù)年會(huì)資料集[C];2000年
9 黃艷;劉東;楊建坤;張恩澤;;某雙層玻璃幕墻建筑自然通風(fēng)的數(shù)值模擬研究[A];全國暖通空調(diào)制冷2004年學(xué)術(shù)年會(huì)專題研討會(huì)發(fā)表論文集[C];2004年
10 徐瑞萍;徐烈;;單側(cè)自然通風(fēng)中庭室內(nèi)熱環(huán)境模擬及分析[A];全國暖通空調(diào)制冷2004年學(xué)術(shù)年會(huì)資料摘要集(2)[C];2004年
相關(guān)重要報(bào)紙文章 前10條
1 歐陽夢(mèng)云;開一扇窗戶有多難?[N];經(jīng)濟(jì)日?qǐng)?bào);2003年
2 嚴(yán)春銀;如何讓病毒“隨風(fēng)而逝”?[N];中國氣象報(bào);2003年
3 王佩璋;自然通風(fēng)空冷凝汽器 邁開節(jié)能環(huán)保新步伐[N];中國電力報(bào);2004年
4 賀慧宇;拂面楊柳風(fēng) 開“窗”話節(jié)能[N];中國建設(shè)報(bào);2008年
5 中國建筑設(shè)計(jì)研究院副院長、總建筑師/崔愷;通風(fēng)和成本:寫字樓設(shè)計(jì)的兩難[N];中國建設(shè)報(bào);2003年
6 記者 毛慶;20多扇“窗戶”讓隧道自由“呼吸”[N];南京日?qǐng)?bào);2006年
7 國家勘察設(shè)計(jì)大師上,F(xiàn)代建筑設(shè)計(jì)集團(tuán)資深總建筑師/蔡鎮(zhèn)鈺;要重視建筑的自然通風(fēng)[N];中國建設(shè)報(bào);2003年
8 本報(bào)記者 韓慶文邋實(shí)習(xí)生 湯學(xué)祥 通訊員 陳斌;“風(fēng)”關(guān)鍵技術(shù)研究全面啟動(dòng)[N];廣東建設(shè)報(bào);2007年
9 劉虹;建筑與健康[N];山西日?qǐng)?bào);2003年
10 李孟姣;深圳品牌房企發(fā)力節(jié)能[N];中國建設(shè)報(bào);2005年
相關(guān)博士學(xué)位論文 前10條
1 郭春梅;天津地區(qū)辦公建筑自然通風(fēng)熱舒適性研究[D];天津大學(xué);2010年
2 司慧萍;自然通風(fēng)動(dòng)態(tài)溫度調(diào)控的智能氣動(dòng)開窗系統(tǒng)[D];浙江大學(xué);2003年
3 王怡;寒冷地區(qū)居住建筑夏季室內(nèi)熱環(huán)境研究[D];西安建筑科技大學(xué);2003年
4 劉淑珍;智能溫室氣動(dòng)開窗溫度調(diào)控系統(tǒng)研究[D];浙江大學(xué);2005年
5 周軍莉;建筑蓄熱與自然通風(fēng)耦合作用下室內(nèi)溫度計(jì)算及影響因素分析[D];湖南大學(xué);2009年
6 韓杰;自然通風(fēng)環(huán)境熱舒適模型及其在長江流域的應(yīng)用研究[D];湖南大學(xué);2009年
7 方廷勇;自然通風(fēng)狀況下的煙氣在典型建筑結(jié)構(gòu)中的遷移及危害性評(píng)價(jià)的研究[D];中國科學(xué)技術(shù)大學(xué);2006年
8 楊振超;日光溫室內(nèi)最佳風(fēng)速指標(biāo)與CFD模擬[D];西北農(nóng)林科技大學(xué);2006年
9 殷維;建筑自然通風(fēng)利用率預(yù)測(cè)與節(jié)能評(píng)估模型研究[D];湖南大學(xué);2010年
10 鄒聲華;復(fù)雜下墊面建筑自然通風(fēng)熱濕特性研究[D];上海大學(xué);2010年
相關(guān)碩士學(xué)位論文 前10條
1 尉強(qiáng);自然通風(fēng)房間熱過程耦合模擬[D];重慶大學(xué);2010年
2 王松華;熱壓自然通風(fēng)和機(jī)械通風(fēng)相互增益的多元通風(fēng)模式研究[D];西安建筑科技大學(xué);2004年
3 屈睿;大型商業(yè)建筑自然通風(fēng)與采光設(shè)計(jì)研究[D];武漢理工大學(xué);2010年
4 張敏慧;中庭結(jié)構(gòu)特性對(duì)高層住宅自然通風(fēng)的影響分析[D];湖南大學(xué);2010年
5 李丹;風(fēng)口、風(fēng)帽強(qiáng)化自然通風(fēng)效果的理論基礎(chǔ)研究[D];西安建筑科技大學(xué);2004年
6 王麗萍;太陽能煙囪提高室內(nèi)熱壓通風(fēng)效果的數(shù)值模擬[D];西安建筑科技大學(xué);2004年
7 石瑩;中美建筑通風(fēng)系統(tǒng)標(biāo)準(zhǔn)對(duì)比及自然通風(fēng)應(yīng)用效果分析[D];重慶大學(xué);2013年
8 李曉;龍灘地下水電站全廠通風(fēng)模型試驗(yàn)與氣流流動(dòng)特性研究[D];重慶大學(xué);2004年
9 李躍群;遮陽構(gòu)件對(duì)室內(nèi)自然通風(fēng)影響的研究[D];華南理工大學(xué);2010年
10 李紅祥;風(fēng)壓作用下自然通風(fēng)阻力特性研究[D];湖南大學(xué);2004年
本文編號(hào):2328380
本文鏈接:http://sikaile.net/kejilunwen/sgjslw/2328380.html