用于Z箍縮診斷裝置的快閥研制
發(fā)布時(shí)間:2017-12-27 09:22
本文關(guān)鍵詞:用于Z箍縮診斷裝置的快閥研制 出處:《原子能科學(xué)技術(shù)》2016年10期 論文類(lèi)型:期刊論文
更多相關(guān)文章: 快閥 Z箍縮 診斷設(shè)備 電磁感應(yīng)
【摘要】:Z箍縮實(shí)驗(yàn)滯止后期負(fù)載產(chǎn)生的微小碎片及其他飛濺物質(zhì)會(huì)污染Z箍縮診斷系統(tǒng)內(nèi)的光學(xué)器件,本文研制了一種基于電磁感應(yīng)原理的快閥,其可用于遮斷微小碎片及其他飛濺物質(zhì)。根據(jù)能量守恒和電路方程,計(jì)算了快閥的運(yùn)動(dòng)速度、遮斷時(shí)間及線圈放電電流等參數(shù),并利用實(shí)驗(yàn)測(cè)量獲得快閥運(yùn)動(dòng)速度為19m/s,遮斷時(shí)刻時(shí)間抖動(dòng)為85μs,實(shí)驗(yàn)測(cè)量與計(jì)算結(jié)果較為吻合。
[Abstract]:Small fragments of Z pinch experiment late stagnation generated by the load and other flying objects will pollute the Z pinch optics diagnosis system, this paper developed a fast valve based on the principle of electromagnetic induction, which can be used for blocking debris and other flying objects. According to the energy conservation and the circuit equations, parameters of motion speed, fast valve shutoff time and coil discharge current was calculated, and the experimental measurements obtained fast valve movement speed is 19m/s, interrupting time jitter is 85 s, the experimental measurement and calculation results are consistent.
【作者單位】: 西北核技術(shù)研究所強(qiáng)脈沖輻射環(huán)境模擬與效應(yīng)國(guó)家重點(diǎn)實(shí)驗(yàn)室;
【基金】:國(guó)家自然科學(xué)基金資助項(xiàng)目(51237006)
【分類(lèi)號(hào)】:TH134
【正文快照】: Z箍縮是一項(xiàng)應(yīng)用廣泛的研究,利用金屬絲陣或噴氣負(fù)載作為一種等離子體輻射源是Z箍縮技術(shù)的一項(xiàng)重要應(yīng)用[1-3]。在Z箍縮研究中,常會(huì)涉及到眾多的輻射參數(shù)及動(dòng)力學(xué)過(guò)程光學(xué)診斷設(shè)備[4-5]。而在Z箍縮實(shí)驗(yàn)中,由于滯止階段結(jié)束后箍縮等離子體柱反彈[6-7],會(huì)產(chǎn)生負(fù)載微小碎片及其他,