幾何參數(shù)對(duì)Ti-Ni合金血管支架支撐性能的影響
[Abstract]:According to the prototype of the support performance of vascular stent, the Ti-Ni alloy stent with different geometric parameters was designed by orthogonal test. The finite element model of vascular stent was established by Pro/E software. The influence of geometric parameters on the support performance of Ti-Ni alloy vascular stent was studied by finite element simulation method. The results were compared with the experimental results to verify the rationality of the finite element analysis results. The results show that the support performance can be improved by increasing the wire diameter of the support wire or the bending radius of the support tendon, while the support performance decreases with the increase of the height of the support tendon, the wire diameter of the support wire and the height of the support tendon. The influence of the bending radius of the bracing bars on the bracing performance was weakened in turn. Among them, the wire diameter and the height of the strands were more significant than the bending radii of the bracing tendons. The support reaction force is tested by plate compression test, and the results are in good agreement with the results of finite element analysis, which verifies the rationality of the finite element analysis results.
【作者單位】: 北京有色金屬研究總院有研億金新材料有限公司;
【基金】:國(guó)家自然科學(xué)基金項(xiàng)目(51401027)資助
【分類(lèi)號(hào)】:TG146.23;R318.08
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 皇甫強(qiáng);于振濤;羅麗娟;牛金龍;張亞峰;賀新杰;;新型高強(qiáng)度鈦合金血管支架的制備與性能研究[J];稀有金屬;2006年S1期
2 毛琳;章曉波;袁廣銀;丁文江;;生物可降解血管支架的研究進(jìn)展[J];材料導(dǎo)報(bào);2010年19期
3 向萍;李敏;;靜電紡絲制備小直徑血管支架[J];材料導(dǎo)報(bào);2011年03期
4 吳遠(yuǎn)浩;周曉晨;李楠;鄭玉峰;;可降解金屬血管支架研究進(jìn)展[J];中國(guó)材料進(jìn)展;2012年09期
5 趙亮;徐艷麗;何孟;李敏;陳雨晴;;雙層蛛絲蛋白血管支架的體外降解研究[J];功能材料;2013年18期
6 馬嘉麗;朱明;繆衛(wèi)東;寇亞明;陳增勝;;鎳鈦合金血管支架力學(xué)性能測(cè)定[J];金屬功能材料;2013年03期
7 ;國(guó)產(chǎn)第一代含藥緩釋血管支架在滬誕生[J];健康大視野;2005年11期
8 王曙東;李雙燕;張幼珠;;小口徑組織工程血管支架的研究與展望[J];蘇州大學(xué)學(xué)報(bào)(工科版);2008年02期
9 張海燕;趙安莎;陳俊英;潘長(zhǎng)江;黃楠;;硬組織切片技術(shù)在血管支架研究中的應(yīng)用[J];食品與藥品;2006年09期
10 ;[J];;年期
相關(guān)會(huì)議論文 前10條
1 馬生梅;王業(yè)南;尚新春;;醫(yī)用血管支架的振動(dòng)分析[A];北京力學(xué)會(huì)第15屆學(xué)術(shù)年會(huì)論文摘要集[C];2009年
2 李寧;顧元憲;;血管支架靜力學(xué)模擬的建模簡(jiǎn)化方案[A];大連理工大學(xué)生物醫(yī)學(xué)工程學(xué)術(shù)論文集(第2卷)[C];2005年
3 田楊;黃耀熊;;不銹鋼血管支架的力學(xué)研究[A];第十次中國(guó)生物物理學(xué)術(shù)大會(huì)論文摘要集[C];2006年
4 張憬;尚新春;;血管支架的固有頻率計(jì)算[A];北京力學(xué)會(huì)第十六屆學(xué)術(shù)年會(huì)論文集[C];2010年
5 邵長(zhǎng)飛;董何彥;劉振峰;;動(dòng)脈血管支架設(shè)計(jì)與支撐性能研究[A];第七屆中國(guó)功能材料及其應(yīng)用學(xué)術(shù)會(huì)議論文集(第2分冊(cè))[C];2010年
6 鐘振茂;劉道志;孫康;;有限元分析技術(shù)在血管支架設(shè)計(jì)中的應(yīng)用[A];2007第一屆全國(guó)介入醫(yī)學(xué)工程學(xué)術(shù)會(huì)議論文匯編[C];2007年
7 王國(guó)輝;王盛強(qiáng);徐益民;;血管支架的加速疲勞測(cè)試[A];2007第一屆全國(guó)介入醫(yī)學(xué)工程學(xué)術(shù)會(huì)議論文匯編[C];2007年
8 黃楠;;抗凝血、抗組織增生的表面仿生的血管支架研究[A];提高全民科學(xué)素質(zhì)、建設(shè)創(chuàng)新型國(guó)家——2006中國(guó)科協(xié)年會(huì)論文集[C];2006年
9 徐仲英;;不同類(lèi)型被膜血管支架的實(shí)驗(yàn)研究[A];中華醫(yī)學(xué)會(huì)第一次全國(guó)介入醫(yī)學(xué)學(xué)術(shù)會(huì)議論文匯編[C];2001年
10 趙麗嬌;孫錕;陳筍;馮其茂;王劍;;小兒生物可降解血管支架新型材料細(xì)胞毒性評(píng)價(jià)[A];2012年江浙滬兒科學(xué)術(shù)年會(huì)暨浙江省醫(yī)學(xué)會(huì)兒科學(xué)分會(huì)學(xué)術(shù)年會(huì)、兒內(nèi)科疾病診治新進(jìn)展國(guó)家級(jí)學(xué)習(xí)班論文匯編[C];2012年
相關(guān)重要報(bào)紙文章 前10條
1 本報(bào)記者 周東;不迷信權(quán)威瞄準(zhǔn)第三代中孵友信血管支架突圍[N];中國(guó)高新技術(shù)產(chǎn)業(yè)導(dǎo)報(bào);2006年
2 特約撰稿 徐錚奎;中低價(jià)位血管支架市場(chǎng)潛力巨大[N];醫(yī)藥經(jīng)濟(jì)報(bào);2010年
3 特約撰稿 徐錚奎;植入式血管支架嬗變謀新生[N];醫(yī)藥經(jīng)濟(jì)報(bào);2013年
4 周東;第三代血管支架遭遇270萬(wàn)美元尷尬[N];中國(guó)高新技術(shù)產(chǎn)業(yè)導(dǎo)報(bào);2006年
5 劉云濤;我國(guó)研制出支架力學(xué)性能快速評(píng)價(jià)工具[N];中國(guó)醫(yī)藥報(bào);2008年
6 胡德榮;國(guó)產(chǎn)含藥緩釋血管支架“出爐”[N];健康報(bào);2004年
7 特約撰稿 徐錚奎;心血管疾病攪動(dòng)亞太[N];醫(yī)藥經(jīng)濟(jì)報(bào);2010年
8 欣華;新一代可吸收型血管支架效果良好[N];醫(yī)藥經(jīng)濟(jì)報(bào);2009年
9 葉國(guó)標(biāo);國(guó)產(chǎn)含藥緩釋血管支架誕生[N];中國(guó)醫(yī)藥報(bào);2004年
10 徐錚奎;美國(guó)醫(yī)療器械產(chǎn)品研發(fā)推陳出新[N];中國(guó)醫(yī)藥報(bào);2008年
相關(guān)博士學(xué)位論文 前10條
1 趙亮;基于雙層蛛絲蛋白血管支架和干細(xì)胞構(gòu)建小直徑組織工程血管及其修復(fù)動(dòng)脈缺損的研究[D];福建師范大學(xué);2014年
2 涂秋芬;以脫細(xì)胞犬動(dòng)脈為基質(zhì)的新型組織工程血管支架的制備和體外再細(xì)胞化研究[D];四川大學(xué);2007年
3 李偉;生物可降解稀土鎂合金血管支架無(wú)縫管材的制備技術(shù)及性能研究[D];重慶大學(xué);2011年
4 劉賓;脫細(xì)胞組織工程血管支架材料的實(shí)驗(yàn)研究[D];第四軍醫(yī)大學(xué);2009年
5 陳華勇;異種小血管支架的實(shí)驗(yàn)移植機(jī)制與CD34陽(yáng)性細(xì)胞生物學(xué)特性的研究[D];中國(guó)醫(yī)科大學(xué);2006年
6 潘長(zhǎng)江;藥物洗脫血管支架研究[D];西南交通大學(xué);2006年
7 張良;1.新型小口徑血管支架和其體內(nèi)生物行為的研究 2.雪旺氏細(xì)胞促進(jìn)骨髓間充質(zhì)干細(xì)胞增殖和向動(dòng)脈樣細(xì)胞分化的實(shí)驗(yàn)研究[D];中國(guó)協(xié)和醫(yī)科大學(xué);2008年
8 虞劍;復(fù)合SDF-1α的組織工程血管支架在小口徑人造血管移植和重建中的研究[D];復(fù)旦大學(xué);2012年
9 劉小麗;血管支架用Mg-Zn-Y-Nd合金的體外生物相容性及表面改性研究[D];北京科技大學(xué);2015年
10 邢s,
本文編號(hào):2206351