反滲透膜元件性能的定壓與定流測試方式
發(fā)布時間:2018-05-27 21:43
本文選題:反滲透 + 膜元件 ; 參考:《水處理技術》2017年05期
【摘要】:運用反滲透膜元件的運行數學模型及相關算例,證明了在膜元件性能測試領域中,設定給水壓時的透鹽率、膜壓降、產水量3項外在指標之間相互關聯(lián),而設定產水量時的透鹽率、膜壓降、給水壓3項外在指標之間相互獨立;且只有設定產水量時的3項外在指標與3項內在指標之間存在一一對應關系,即可以從可測的外在指標直接反映不可測的內在指標。進而明確了在進行膜元件性能測試時,定流量測試方式較定壓力測試方式具有優(yōu)勢。
[Abstract]:By using the mathematical model of reverse osmosis (RO) membrane element operation and related calculation examples, it is proved that in the field of performance testing of membrane element, the three external indexes, such as salt permeability, membrane pressure drop and water yield, are related to each other when water pressure is set. The salt permeability, membrane pressure drop and water supply pressure are independent of each other, and only the three external indexes and the three internal indexes have a one-to-one corresponding relationship. That is to say, we can directly reflect the unmeasurable internal index from the measurable external index. Furthermore, it is clear that the constant flow test method is superior to the constant pressure test method in the performance test of membrane components.
【作者單位】: 天津城建大學環(huán)境與市政工程學院;
【分類號】:TQ051.893
【相似文獻】
相關期刊論文 前4條
1 ;朗盛推出反滲透膜元件產品[J];粘接;2012年05期
2 靖大為;羅浩;仲懷明;徐平;;反滲透膜元件的指標離散特性與安裝位置優(yōu)化[J];水處理技術;2007年10期
3 安朋;;藍星東麗反滲透膜元件取得領先地位[J];化工管理;2013年09期
4 ;[J];;年期
相關重要報紙文章 前2條
1 本報記者 班健;保護地球進入公司價值觀[N];中國環(huán)境報;2010年
2 本報記者 陳頤;陶氏:貼近市場 加強研發(fā)[N];經濟日報;2010年