基于偏振探測(cè)的CARS非共振背景抑制與分離
發(fā)布時(shí)間:2018-06-20 18:47
本文選題:光譜診斷 + 溫度測(cè)量��; 參考:《光子學(xué)報(bào)》2017年S1期
【摘要】:為消除非共振背景干擾,提高相干反斯托克斯拉曼散射測(cè)量精度,研究了基于偏振探測(cè)的相干反斯托克斯拉曼散射非共振背景抑制與分離.首先,從理論上證明了相干反斯托克斯拉曼散射信號(hào)強(qiáng)度只取決于三階非線性極化率共振部分,而與非共振部分無(wú)關(guān),并且三階極化率共振部分與非共振部分偏振方向不一致,為偏振相干反斯托克斯拉曼散射提供了理論支撐;然后,以平面火焰爐溫度場(chǎng)為研究對(duì)象,設(shè)計(jì)了偏振相干反斯托克斯拉曼散射探測(cè)系統(tǒng)實(shí)施方案,并與熱電偶、常規(guī)相干反斯托克斯拉曼散射兩種方法在相同條件下開(kāi)展了溫度測(cè)量對(duì)比實(shí)驗(yàn).實(shí)驗(yàn)結(jié)果表明:常規(guī)相干反斯托克斯拉曼散射方法的測(cè)量相對(duì)誤差優(yōu)于7%,測(cè)量相對(duì)不確定度優(yōu)于7%;偏振相干反斯托克斯拉曼散射方法的測(cè)量相對(duì)誤差優(yōu)于4%,測(cè)量相對(duì)不確定度優(yōu)于5%;相同工況條件下與常規(guī)相干反斯托克斯拉曼散射相比,偏振相干反斯托克斯拉曼散射最接近均值的擬合光譜更加平滑.偏振相干反斯托克斯拉曼散射具有更小的擬合誤差,是一種更為有效的相干反斯托克斯拉曼散射診斷方法.
[Abstract]:In order to eliminate non-resonant background interference and improve the measurement accuracy of coherent anti-Stokes Raman scattering, the non-resonance background suppression and separation of coherent anti-Stokes Raman scattering based on polarization detection are studied. Firstly, it is proved theoretically that the intensity of coherent anti-Stokes Raman scattering signal depends only on the third order nonlinear polarizability resonance, but is independent of the non-resonance part, and the third order polarizability resonance part is not consistent with the non-resonant part polarization direction. It provides a theoretical support for polarization coherent anti-Stokes Raman scattering. Then, taking the temperature field of plane flame furnace as the research object, the scheme of polarization coherent anti-Stokes Raman scattering detection system is designed and compared with the thermocouple. The conventional coherent anti-Stokes Raman scattering method is used to compare the temperature measurements under the same conditions. The experimental results show that the relative error of the conventional coherent anti-Stokes Raman scattering method is better than that of the conventional anti-Stokes Raman scattering method, and the relative error of the conventional anti-Stokes Raman scattering method is better than that of the conventional anti-Stokes Raman scattering method. The relative uncertainty is better than 5. Compared with the conventional coherent anti-Stokes Raman scattering under the same operating conditions, The fitting spectra of polarization coherent anti-Stokes Raman scattering are smoother. Polarization coherent anti-Stokes Raman scattering has smaller fitting error and is a more effective diagnostic method for coherent anti-Stokes Raman scattering.
【作者單位】: 中國(guó)空氣動(dòng)力研究與發(fā)展中心超高速空氣動(dòng)力研究所高超聲速?zèng)_壓發(fā)動(dòng)機(jī)技術(shù)重點(diǎn)實(shí)驗(yàn)室;中國(guó)空氣動(dòng)力研究與發(fā)展中心設(shè)備設(shè)計(jì)及測(cè)試技術(shù)研究所;
【基金】:國(guó)家自然科學(xué)基金(Nos.11272337,11272338) 高超聲速?zèng)_壓發(fā)動(dòng)機(jī)技術(shù)重點(diǎn)實(shí)驗(yàn)室開(kāi)放基金(No.STS/MY-KFKT-2015001)資助~~
【分類號(hào)】:O657.37
【相似文獻(xiàn)】
相關(guān)期刊論文 前2條
1 呂永鋼;李治軍;吳驪珠;王鵬;付立民;張建平;;利用時(shí)間分辨相干反斯托克斯拉曼散射技術(shù)研究光催化產(chǎn)氫反應(yīng)動(dòng)力學(xué)[J];物理化學(xué)學(xué)報(bào);2013年08期
2 ;[J];;年期
相關(guān)會(huì)議論文 前2條
1 郭礎(chǔ);高振;劉殿友;華巒;;苯的寬帶相干反斯托克斯喇曼散射[A];第一屆全國(guó)光散射會(huì)議會(huì)議指南[C];1981年
2 花曉清;冷靜;楊何平;沙國(guó)河;張存浩;;單縱模Nd:YAG二倍頻泵浦時(shí)O_2氣中高效喇曼轉(zhuǎn)化效率[A];第九屆全國(guó)化學(xué)動(dòng)力學(xué)會(huì)議論文摘要集[C];2005年
,本文編號(hào):2045326
本文鏈接:http://sikaile.net/kejilunwen/huaxue/2045326.html