直接注入高效霧化器-電感耦合等離子體原子發(fā)射光譜法測定船用燃料油中26種元素
發(fā)布時間:2018-03-19 03:11
本文選題:電感耦合等離子體原子發(fā)射光譜法 切入點:直接注入高效霧化器 出處:《理化檢驗(化學分冊)》2017年12期 論文類型:期刊論文
【摘要】:樣品經(jīng)硝酸-過氧化氫微波消解后,采用可拆卸式直接注入高效霧化器-電感耦合等離子體原子發(fā)射光譜法測定船用燃料油中釩、鋁、鈣、鋅、鎳、銅等26種微量元素的含量,通過多譜線擬合校正法(MSF)校正了Cu對P 213.617nm和P 214.914nm所產(chǎn)生的光譜干擾。26種元素的線性范圍在10.0mg·L~(-1)內(nèi),檢出限(3s)為0.001~0.087mg·L~(-1)。加標回收率在92.1%~106%之間,測定值的相對標準偏差(n=7)在0.46%~2.7%之間。采用此方法對船用燃料油標準物質(zhì)中Fe、Ni、V、S進行測定,測定值與參考值一致。
[Abstract]:After microwave digestion with nitric acid and hydrogen peroxide, 26 trace elements such as vanadium, aluminum, calcium, zinc, nickel and copper in marine fuel oil were determined by detachable direct injection nebulizer and inductively coupled plasma atomic emission spectrometry. The linear range of the spectral interference between Cu and P213.617nm and P214.914nm was 10.0mg 路L ~ (-1), and the detection limit was 0.001n / L 0.087mg 路L ~ (-1) 路L ~ (-1). The recovery of Cu was between 92.1g 路L ~ (-1) and 10.0 mg 路L ~ (-1) 路L ~ (-1). The relative standard deviation of the measured value is between 0.46% and 2.7%. This method is used for the determination of Fetin NiNiVN S in the standard material of marine fuel oil, and the measured value is in agreement with the reference value.
【作者單位】: 深圳市計量質(zhì)量檢測研究院;
【基金】:國家標準制定計劃能源項目(20131689-7-469) 2015年度廣東省質(zhì)監(jiān)局科技項目(2015CZ06)
【分類號】:O657.31;TE626.2
,
本文編號:1632556