300MW雙饋風(fēng)電場(chǎng)STATCOM裝置容量配置的研究

發(fā)布時(shí)間:2018-10-09 11:58
【摘要】:由于大規(guī)模風(fēng)力發(fā)電系統(tǒng)的規(guī)劃與建設(shè),風(fēng)電場(chǎng)的并網(wǎng)對(duì)電網(wǎng)的影響越來(lái)越嚴(yán)重,其中包括風(fēng)電場(chǎng)并網(wǎng)點(diǎn)電壓穩(wěn)定問(wèn)題。在實(shí)際工程建設(shè)中,對(duì)于雙饋風(fēng)電場(chǎng)無(wú)功補(bǔ)償裝置容量的配置,做到既能符合雙饋風(fēng)電場(chǎng)并網(wǎng)要求又能兼顧經(jīng)濟(jì)性尤為必要。本文將STATCOM和DFIG作為研究對(duì)象,對(duì)兩者的運(yùn)行原理、數(shù)學(xué)模型、控制策略進(jìn)行了詳細(xì)的研究分析工作。在MATLAB/Simulink仿真環(huán)境下依據(jù)所提出的數(shù)學(xué)模型搭建了含STATCOM裝置的雙饋風(fēng)電場(chǎng)模型,建立了采用定子磁鏈定向矢量控制的轉(zhuǎn)子側(cè)換流器控制模型、采用電網(wǎng)電壓定向矢量控制的網(wǎng)側(cè)換流器控制模型、槳距角控制模型以及包含電壓控制和無(wú)功功率控制的STATCOM控制器模型,在此基礎(chǔ)上,分別對(duì)DFIG和STATCOM裝置進(jìn)行了并網(wǎng)仿真分析,驗(yàn)證了模型的正確性。論文提出一種方法來(lái)確定雙饋風(fēng)電場(chǎng)STATCOM裝置的容量,該方法需先估算雙饋風(fēng)電場(chǎng)的無(wú)功損耗,其次依據(jù)雙饋風(fēng)電場(chǎng)參數(shù)進(jìn)行等效建模,對(duì)其穩(wěn)態(tài)運(yùn)行數(shù)據(jù)進(jìn)行簡(jiǎn)化的潮流計(jì)算,由此確定STATCOM裝置的配置容量。在此基礎(chǔ)上進(jìn)一步探討了影響雙饋風(fēng)電場(chǎng)STATCOM裝置容量配置的其他因素,其中包括風(fēng)電場(chǎng)出力情況、電網(wǎng)電壓跌落情況、輸電線路長(zhǎng)度,以及配置不同容量的STATCOM裝置時(shí)輸出無(wú)功的變化情況。結(jié)果表明:隨著風(fēng)電場(chǎng)出力增加風(fēng)電場(chǎng)對(duì)無(wú)功的需求增加,在一定程度內(nèi)電網(wǎng)電壓跌落程度與維持PCC點(diǎn)電壓穩(wěn)定所需的無(wú)功功率呈線性關(guān)系,系統(tǒng)對(duì)無(wú)功的需求隨輸電線路長(zhǎng)度的增加而增加且增勢(shì)會(huì)逐漸變緩,在電網(wǎng)電氣特性固定的情況下隨STATCOM裝置所配置的容量的增加其輸出的無(wú)功功率會(huì)近似達(dá)到飽和。本文主要提出了一種方法用于確定STATCOM裝置的容量,并通過(guò)與實(shí)際300MW雙饋風(fēng)電場(chǎng)所配置的容量進(jìn)行了對(duì)比,驗(yàn)證了所提方法的正確性。本文進(jìn)一步探究了影響雙饋風(fēng)電場(chǎng)STATCOM裝置容量配置的其他因素,為無(wú)功補(bǔ)償容量的配置提供了依據(jù),也為提高雙饋風(fēng)電場(chǎng)無(wú)功補(bǔ)償方案的經(jīng)濟(jì)性提供了指導(dǎo)。
[Abstract]:Due to the planning and construction of large-scale wind power system, the influence of grid connection of wind farm is more and more serious, including the problem of voltage stability of wind farm and network. In actual engineering construction, it is necessary for the configuration of reactive power compensator capacity of doubly-fed wind farm to meet the requirements of doubly-fed wind farm and to give consideration to economy. In this paper, STATCOM and DFIG are taken as the research objects, and the operation principle, mathematical model and control strategy of both are studied and analyzed in detail. Based on the mathematical model proposed in MATLAB/Simulink simulation environment, a doubly-fed wind farm model with STATCOM device is built, and a rotor side converter control model using stator flux linkage directional vector control is established. The grid-side converter control model, propeller pitch control model and STATCOM controller model including voltage control and reactive power control are adopted in this paper. On the basis of this, the grid-connected simulation analysis of DFIG and STATCOM devices is carried out, respectively. The correctness of the model is verified. This paper presents a method to determine the capacity of the STATCOM device in a doubly-fed wind farm. This method first estimates the reactive power loss of the doubly-fed wind farm, and then carries out a simplified power flow calculation based on the parameters of the doubly-fed wind farm. Thus, the configuration capacity of the STATCOM device is determined. On this basis, other factors affecting the capacity configuration of the STATCOM unit in a doubly-fed wind farm are further discussed, including wind farm output, grid voltage drop, transmission line length, And the variation of output reactive power when the STATCOM device with different capacity is configured. The results show that with the increase of wind farm output, the demand for reactive power of wind farm increases. To some extent, the voltage drop of power grid is linearly related to the reactive power required to maintain the voltage stability of PCC points. The demand for reactive power in the system increases with the length of transmission line and the increasing potential will slow down gradually. When the electrical characteristics of the power network are fixed, the output reactive power of the system will be approximately saturated with the increase of the configuration capacity of the STATCOM device. In this paper, a method is proposed to determine the capacity of the STATCOM device, and the correctness of the proposed method is verified by comparing it with the capacity of the actual 300MW doubly-fed wind farm. This paper further explores the other factors that affect the capacity configuration of the STATCOM unit in a doubly-fed wind farm, which provides a basis for the allocation of reactive power compensation capacity, and also provides guidance for improving the economy of the reactive power compensation scheme in a doubly-fed wind farm.
【學(xué)位授予單位】:昆明理工大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2017
【分類(lèi)號(hào)】:TM614;TM761.12

【參考文獻(xiàn)】

相關(guān)期刊論文 前10條

1 姚駿;周特;陳知前;;電網(wǎng)對(duì)稱(chēng)故障下定速異步風(fēng)電場(chǎng)STATCOM容量配置研究[J];電工技術(shù)學(xué)報(bào);2016年01期

2 韓笑;王琳;;2012年全球風(fēng)電發(fā)展現(xiàn)狀及未來(lái)發(fā)展趨勢(shì)預(yù)測(cè)[J];科技和產(chǎn)業(yè);2013年11期

3 田桂珍;王生鐵;劉廣忱;王文平;;采用STATCOM改善籠型機(jī)風(fēng)電場(chǎng)性能的機(jī)理分析與實(shí)驗(yàn)研究[J];電網(wǎng)技術(shù);2013年07期

4 高虎;王紅芳;;2012年我國(guó)風(fēng)電市場(chǎng)發(fā)展綜述[J];中國(guó)能源;2013年04期

5 鄭重;楊耕;耿華;;配置STATCOM的DFIG風(fēng)電場(chǎng)在不對(duì)稱(chēng)電網(wǎng)故障下的控制策略[J];中國(guó)電機(jī)工程學(xué)報(bào);2013年19期

6 王凱;談?dòng)⑸?;風(fēng)電場(chǎng)最佳動(dòng)態(tài)無(wú)功補(bǔ)償容量的選擇[J];電機(jī)技術(shù);2012年05期

7 賀益康;胡家兵;;雙饋異步風(fēng)力發(fā)電機(jī)并網(wǎng)運(yùn)行中的幾個(gè)熱點(diǎn)問(wèn)題[J];中國(guó)電機(jī)工程學(xué)報(bào);2012年27期

8 王成福;梁軍;張利;馮江霞;韓學(xué)山;;考慮風(fēng)功率分布規(guī)律的風(fēng)電場(chǎng)無(wú)功補(bǔ)償容量?jī)?yōu)化決策[J];電力系統(tǒng)自動(dòng)化;2012年14期

9 張永武;孫愛(ài)民;張?jiān)闯?李玉志;林勇;吳金玉;李達(dá);;風(fēng)電場(chǎng)無(wú)功補(bǔ)償容量配置及優(yōu)化運(yùn)行[J];電力系統(tǒng)及其自動(dòng)化學(xué)報(bào);2011年06期

10 朱洪波;宋穎巍;劉巖;李華;;風(fēng)電場(chǎng)無(wú)功補(bǔ)償計(jì)算方法與容量配置的研究[J];現(xiàn)代電力;2011年06期

相關(guān)博士學(xué)位論文 前1條

1 胡家兵;雙饋異步風(fēng)力發(fā)電機(jī)系統(tǒng)電網(wǎng)故障穿越(不間斷)運(yùn)行研究[D];浙江大學(xué);2009年

相關(guān)碩士學(xué)位論文 前10條

1 宋鑫;并網(wǎng)風(fēng)電場(chǎng)無(wú)功補(bǔ)償裝置配置策略研究[D];華北電力大學(xué);2015年

2 汪春莉;STATCOM提高風(fēng)電場(chǎng)低電壓穿越能力的控制措施研究[D];華北電力大學(xué);2015年

3 李清;電網(wǎng)電壓不平衡且諧波條件下雙饋風(fēng)電系統(tǒng)運(yùn)行與控制研究[D];重慶大學(xué);2014年

4 胡羽川;含大規(guī)模風(fēng)電電力系統(tǒng)的無(wú)功補(bǔ)償配置研究[D];華中科技大學(xué);2014年

5 劉思;風(fēng)電場(chǎng)靜止無(wú)功補(bǔ)償方案與補(bǔ)償策略研究[D];華北電力大學(xué);2014年

6 付曉明;張家口某風(fēng)電場(chǎng)無(wú)功補(bǔ)償系統(tǒng)設(shè)計(jì)[D];東北大學(xué);2014年

7 李歡;含大規(guī)模風(fēng)電場(chǎng)的電網(wǎng)的無(wú)功補(bǔ)償控制策略研究[D];華北電力大學(xué);2014年

8 韓強(qiáng);基于STATCOM的雙饋風(fēng)電場(chǎng)無(wú)功電壓控制系統(tǒng)的研究[D];華北電力大學(xué);2013年

9 李少博;風(fēng)電場(chǎng)無(wú)功補(bǔ)償優(yōu)化配置[D];天津大學(xué);2012年

10 李鴻儒;大規(guī)模雙饋型風(fēng)電并網(wǎng)穩(wěn)定性仿真研究[D];西南交通大學(xué);2012年



本文編號(hào):2259253

資料下載
論文發(fā)表

本文鏈接:http://sikaile.net/kejilunwen/dianlidianqilunwen/2259253.html


Copyright(c)文論論文網(wǎng)All Rights Reserved | 網(wǎng)站地圖 |

版權(quán)申明:資料由用戶2210f***提供,本站僅收錄摘要或目錄,作者需要?jiǎng)h除請(qǐng)E-mail郵箱bigeng88@qq.com
夜夜嗨激情五月天精品| 不卡视频在线一区二区三区| 国产一区国产二区在线视频| 中文字幕久久精品亚洲乱码| 好吊色免费在线观看视频| 欧美精品久久99九九| 日韩人妻中文字幕精品| 亚洲熟妇中文字幕五十路| 国产一区二区精品丝袜| 日韩午夜老司机免费视频| 亚洲中文在线中文字幕91| 久久精品亚洲精品一区| 亚洲精品蜜桃在线观看| 丰满人妻熟妇乱又伦精另类视频| 日韩人妻精品免费一区二区三区| 爱草草在线观看免费视频| 日本道播放一区二区三区| 白白操白白在线免费观看 | 国产三级视频不卡在线观看| 国产一区二区三区色噜噜| 国产毛片对白精品看片| 成人午夜激情在线免费观看| 中文字幕日韩欧美理伦片| 欧美一区二区三区视频区| 福利专区 久久精品午夜| 国产水滴盗摄一区二区| 一个人的久久精彩视频| 欧美成人欧美一级乱黄| 亚洲一区二区三区日韩91| 午夜精品在线视频一区| 欧美一级内射一色桃子| 日本中文在线不卡视频| 人人爽夜夜爽夜夜爽精品视频| 国产不卡在线免费观看视频| 国产精品尹人香蕉综合网| 免费观看潮喷到高潮大叫| 香港国产三级久久精品三级| 日本福利写真在线观看| 亚洲一区二区三区福利视频| 国产女高清在线看免费观看| 欧美中文字幕一区在线|