基于PIR控制器的CSC-DPMSG-WGS低電壓穿越控制
發(fā)布時(shí)間:2018-09-10 08:03
【摘要】:提出了一種基于比例—積分—諧振(PIR)控制器,且適用于電流源型永磁直驅(qū)風(fēng)力發(fā)電系統(tǒng)(CSC-DPMSG-WGS)的低電壓穿越運(yùn)行控制方案。根據(jù)所提出的方法,電網(wǎng)故障時(shí),通過(guò)機(jī)側(cè)變換器控制來(lái)限制風(fēng)力發(fā)電機(jī)的電磁功率,以實(shí)現(xiàn)機(jī)側(cè)和網(wǎng)側(cè)的功率平衡;網(wǎng)側(cè)控制器在正序旋轉(zhuǎn)坐標(biāo)系下采用PIR控制器同時(shí)對(duì)正負(fù)序電流進(jìn)行無(wú)差控制,以消除兩倍基頻的功率波動(dòng),進(jìn)而穩(wěn)定直流電流。仿真與實(shí)驗(yàn)結(jié)果表明,所提出的控制方案在電網(wǎng)對(duì)稱及不對(duì)稱故障下均可有效降低直流電流波動(dòng),并實(shí)現(xiàn)電流源型永磁直驅(qū)風(fēng)力發(fā)電系統(tǒng)的低電壓穿越。
[Abstract]:A low voltage traversing operation control scheme for current source permanent magnet direct drive wind power generation (CSC-DPMSG-WGS) system based on proportional integral-resonant (PIR) controller is presented. According to the proposed method, the electromagnetic power of the wind turbine is limited by the control of the machine side converter in case of power network failure, so that the power balance between the machine side and the grid side can be realized. In order to eliminate the power fluctuation of double fundamental frequency and stabilize the DC current, the PIR controller is used to control the positive and negative sequence currents simultaneously in the positive sequence rotation coordinate system. The simulation and experimental results show that the proposed control scheme can effectively reduce the DC current fluctuation and realize the low voltage traversing of the current source permanent magnet direct drive wind power generation system.
【作者單位】: 合肥工業(yè)大學(xué)教育部光伏系統(tǒng)工程研究中心;
【基金】:國(guó)家自然科學(xué)基金資助項(xiàng)目(51077033) 國(guó)家重點(diǎn)基礎(chǔ)研究發(fā)展計(jì)劃(973計(jì)劃)資助項(xiàng)目(2009CB219708) 廣東省引進(jìn)創(chuàng)新團(tuán)隊(duì)項(xiàng)目(2011N015)~~
【分類號(hào)】:TM614
,
本文編號(hào):2233858
[Abstract]:A low voltage traversing operation control scheme for current source permanent magnet direct drive wind power generation (CSC-DPMSG-WGS) system based on proportional integral-resonant (PIR) controller is presented. According to the proposed method, the electromagnetic power of the wind turbine is limited by the control of the machine side converter in case of power network failure, so that the power balance between the machine side and the grid side can be realized. In order to eliminate the power fluctuation of double fundamental frequency and stabilize the DC current, the PIR controller is used to control the positive and negative sequence currents simultaneously in the positive sequence rotation coordinate system. The simulation and experimental results show that the proposed control scheme can effectively reduce the DC current fluctuation and realize the low voltage traversing of the current source permanent magnet direct drive wind power generation system.
【作者單位】: 合肥工業(yè)大學(xué)教育部光伏系統(tǒng)工程研究中心;
【基金】:國(guó)家自然科學(xué)基金資助項(xiàng)目(51077033) 國(guó)家重點(diǎn)基礎(chǔ)研究發(fā)展計(jì)劃(973計(jì)劃)資助項(xiàng)目(2009CB219708) 廣東省引進(jìn)創(chuàng)新團(tuán)隊(duì)項(xiàng)目(2011N015)~~
【分類號(hào)】:TM614
,
本文編號(hào):2233858
本文鏈接:http://sikaile.net/kejilunwen/dianlidianqilunwen/2233858.html
最近更新
教材專著