天堂国产午夜亚洲专区-少妇人妻综合久久蜜臀-国产成人户外露出视频在线-国产91传媒一区二区三区

空氣載能輻射末端應(yīng)用試驗(yàn)研究

發(fā)布時(shí)間:2019-02-13 07:11
【摘要】:隨著時(shí)代的發(fā)展,普通空調(diào)末端系統(tǒng)的技術(shù)已經(jīng)非常的成熟,但是空氣載能輻射末端系統(tǒng)還是很少被人們所了解的?諝廨d能輻射空調(diào)末端技術(shù)繼承了傳統(tǒng)輻射末端系統(tǒng)低能耗、高舒適性、噪聲低的特點(diǎn),并解決了傳統(tǒng)輻射末端系統(tǒng)的施工復(fù)雜、維護(hù)難度高、容易結(jié)露等問(wèn)題?諝廨d能輻射空調(diào)末端系統(tǒng)熱舒適性問(wèn)題是空氣載能輻射空調(diào)系統(tǒng)設(shè)計(jì)中的關(guān)鍵部分,也可以作為設(shè)備選型的一項(xiàng)依據(jù),基于熱舒適性的節(jié)能性研究既能滿足熱舒適性要求,也能在最大程度上得到能耗節(jié)約。另外針對(duì)冬冷夏熱地區(qū)的供暖問(wèn)題進(jìn)行了單獨(dú)研究,為空氣載能輻射末端系統(tǒng)可成為冬冷夏熱地區(qū)冬季供熱的選擇之一提供實(shí)驗(yàn)依據(jù)。本文對(duì)湖南大學(xué)紅葉樓一間辦公室的空氣載能輻射空調(diào)系統(tǒng)進(jìn)行了現(xiàn)場(chǎng)測(cè)試,為空氣載能輻射空調(diào)系統(tǒng)的熱舒適性以及節(jié)能性提供了大量的寶貴的實(shí)測(cè)數(shù)據(jù),另外對(duì)常德某藥檢所的空氣載能輻射空調(diào)系統(tǒng)供暖研究,為冬冷夏熱地區(qū)供暖問(wèn)題的解決提供數(shù)據(jù)與分析方法,本文具體工作和結(jié)論如下:(1)通過(guò)對(duì)所選空調(diào)房間的空氣溫度、空氣相對(duì)濕度、空氣速度、平均輻射溫度以及參與測(cè)試的人體衣著熱阻和人體代謝進(jìn)行實(shí)際測(cè)量和計(jì)算,并且利用Fanger教授所提出的熱舒適評(píng)價(jià)指標(biāo)PMV和PPD,得出了滿足人體熱舒適性要求的溫度范圍,并且將計(jì)算結(jié)果與真人綜合調(diào)查研究進(jìn)行對(duì)比核實(shí),印證了所得結(jié)果的可靠性。結(jié)果表明在相同的熱舒適性要求下,空氣載能輻射末端系統(tǒng)相較于普通常用空調(diào)末端系統(tǒng)具有較為不錯(cuò)的節(jié)能效果,實(shí)驗(yàn)測(cè)得的最大節(jié)能率可達(dá)26.4%。(2)通過(guò)對(duì)常德藥檢所某天平室的頂板溫度、墻壁溫度、地面溫度以及室內(nèi)空氣溫度的測(cè)量,再結(jié)合各測(cè)試點(diǎn)的熱流密度以及頂板內(nèi)送、回風(fēng)風(fēng)速,并將測(cè)試數(shù)據(jù)與測(cè)試時(shí)間制成圖表形式,以便于進(jìn)行合理分析,結(jié)果表明送風(fēng)區(qū)頂棚溫度和回風(fēng)區(qū)頂棚溫度峰值較為同步,無(wú)明顯相位差。通過(guò)頂板與地面之間的輻射換熱能有效的提高地面溫度,壁面也能保持較高的溫度,且不同供熱工況下,地面溫度均高于室內(nèi)空氣平均預(yù)測(cè)溫度,這表明在冬季供暖的過(guò)程中,與人體更加接近的地面具有一個(gè)較為舒適的溫度。以上均可為空氣載能輻射末端系統(tǒng)可成為冬冷夏熱地區(qū)冬季供熱的選擇之一提供可靠依據(jù)。
[Abstract]:With the development of the times, the technology of air conditioning terminal system has been very mature, but the end system of airborne energy radiation is rarely known. The air borne radiation air conditioning terminal technology inherits the characteristics of low energy consumption, high comfort and low noise of the traditional radiation end system, and solves the problems of complex construction, high maintenance difficulty and easy condensation of the traditional radiation end system. The thermal comfort problem of the air energy carrying radiation air conditioning terminal system is a key part in the design of the air energy carrying radiation air conditioning system, and it can also be used as a basis for the selection of the equipment. The study of energy saving based on the thermal comfort can not only meet the requirements of the thermal comfort. Also can obtain energy consumption saving to the greatest extent. In addition, the heating problem in the area of cold winter and hot summer is studied separately, which provides the experimental basis for the end system of air energy transfer radiation to be one of the choices of heat supply in winter in the area of cold winter and hot summer. In this paper, the air energy carrying radiation air conditioning system in an office of Hongye Building, Hunan University, is tested on the spot, which provides a great deal of valuable measured data for the thermal comfort and energy saving of the air energy carrying radiation air conditioning system. In addition, the study on the heating of the air energy carrying radiation air conditioning system in a drug control institute in Changde provides data and analysis methods for solving the heating problems in the cold and hot areas in winter and summer. The specific work and conclusions of this paper are as follows: (1) the air temperature, air relative humidity, air velocity, average radiation temperature, thermal resistance and metabolism of human body were measured and calculated. The thermal comfort evaluation index PMV and PPD, proposed by Professor Fanger are used to obtain the temperature range to meet the requirements of human thermal comfort. The results are compared with the real person comprehensive investigation and verify the reliability of the obtained results. The results show that under the same thermal comfort requirement, the air energy carrying radiation terminal system has a better energy saving effect than that of the common air conditioning terminal system. The maximum energy saving rate measured by the experiment can be as high as 26.4um. (2) by measuring the roof temperature, wall temperature, floor temperature and indoor air temperature of a certain balance chamber of Changde Drug Control Institute, Combined with the heat flux of each test point and the wind speed of the inside roof and the return air, the test data and the test time are made into chart form, so that the reasonable analysis can be made. The results show that the peak value of roof temperature in the air supply area is more synchronous with that in the return air area, and there is no obvious phase difference. Through the radiant heat transfer between the roof and the ground, the temperature of the ground can be raised effectively, and the temperature of the wall can be kept high, and under different heating conditions, the ground temperature is higher than the average predicted temperature of indoor air, which indicates that in the process of heating in winter, The ground closer to the human body has a more comfortable temperature. All of the above can provide reliable basis for the selection of air energy carrying radiation terminal system as one of the winter heating options in cold winter and hot summer areas.
【學(xué)位授予單位】:湖南大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2015
【分類號(hào)】:TU831

【相似文獻(xiàn)】

相關(guān)期刊論文 前10條

1 張洪弟;汪學(xué)騫;;服裝及紡織品濕熱舒適性的灰色關(guān)聯(lián)分析[J];山東紡織工學(xué)院學(xué)報(bào);1991年01期

2 賈慶賢,趙榮義;風(fēng)速頻譜對(duì)人體熱舒適性的影響[J];清華大學(xué)學(xué)報(bào)(自然科學(xué)版);2001年06期

3 杜強(qiáng);;基于熱舒適性的室內(nèi)環(huán)境控制分析[J];河北能源職業(yè)技術(shù)學(xué)院學(xué)報(bào);2008年01期

4 曹彬;朱穎心;歐陽(yáng)沁;周翔;黃莉;;北京地區(qū)冬季室內(nèi)人體熱舒適性及熱適應(yīng)性調(diào)查[J];暖通空調(diào);2010年05期

5 周成梅;朱庭浩;;某空調(diào)辦公室夏季熱舒適性分析[J];科技信息;2010年25期

6 張吉禮;馬良棟;趙天怡;;建筑環(huán)境熱舒適性研究進(jìn)展與趨勢(shì)分析[J];建筑熱能通風(fēng)空調(diào);2011年01期

7 黃俊;顧潔;王曉博;;多孔太陽(yáng)墻式太陽(yáng)能房間與普通房間熱舒適性分析[J];節(jié)能;2012年02期

8 鄭立星;盧葦;陳洪杰;馮冰凌;;基于空調(diào)使用行為的南寧地區(qū)夏季室內(nèi)熱舒適性研究[J];四川建筑科學(xué)研究;2012年06期

9 王漢青;康良麒;李端茹;楊榮郭;;某辦公室夏季熱舒適性數(shù)值模擬與實(shí)測(cè)分析[J];建筑熱能通風(fēng)空調(diào);2013年01期

10 寧勇飛;謝吉平;李惠敏;;內(nèi)廊式建筑南北房間熱舒適性評(píng)價(jià)[J];建筑熱能通風(fēng)空調(diào);2013年06期

相關(guān)會(huì)議論文 前10條

1 諸明杰;;用動(dòng)態(tài)情況分析商場(chǎng)冬季熱舒適性空調(diào)參數(shù)[A];全國(guó)暖通空調(diào)制冷1998年學(xué)術(shù)年會(huì)論文集(2)[C];1998年

2 李艷菊;劉俊杰;;某中學(xué)教室室內(nèi)空氣污染及熱舒適性研究[A];全國(guó)暖通空調(diào)制冷2006學(xué)術(shù)年會(huì)資料集[C];2006年

3 茅靳豐;毛維;付建明;范良凱;;地下工程內(nèi)空調(diào)布置方式對(duì)熱舒適性的影響[A];全國(guó)暖通空調(diào)制冷2004年學(xué)術(shù)年會(huì)資料摘要集(1)[C];2004年

4 王季樓;卞康;;高大空間分層空調(diào)建立條件及熱舒適性的若干因素分析[A];全國(guó)暖通空調(diào)制冷2008年學(xué)術(shù)年會(huì)論文集[C];2008年

5 王威;狄洪發(fā);;新型輻射吊頂供暖的實(shí)驗(yàn)研究與熱舒適性討論[A];全國(guó)暖通空調(diào)制冷2002年學(xué)術(shù)年會(huì)論文集[C];2002年

6 趙立華;張泓森;;輻射板采暖房間熱舒適性影響因素分析[A];全國(guó)暖通空調(diào)制冷2004年學(xué)術(shù)年會(huì)資料摘要集(2)[C];2004年

7 陶培德;;人體對(duì)環(huán)境熱適性反應(yīng)的差異[A];全國(guó)暖通空調(diào)制冷1990年學(xué)術(shù)年會(huì)論文集(下)[C];1990年

8 楊靜竹;雷波;;火車(chē)站熱舒適性調(diào)查與分析研究[A];第十四屆西南地區(qū)暖通空調(diào)熱能動(dòng)力學(xué)術(shù)年會(huì)論文集[C];2011年

9 郭利華;朱能;蔣薇;;人體熱舒適性的實(shí)驗(yàn)研究[A];全國(guó)暖通空調(diào)制冷2002年學(xué)術(shù)文集[C];2002年

10 許樹(shù)文;王煒;陳菊芳;;加強(qiáng)基礎(chǔ)研究,提高國(guó)產(chǎn)西服的熱舒適性[A];2006年全國(guó)服裝科技創(chuàng)新與發(fā)展論壇論文集[C];2006年

相關(guān)重要報(bào)紙文章 前4條

1 李成偉;空氣的溫度、濕度、焓值與熱舒適性[N];中國(guó)建設(shè)報(bào);2013年

2 李成偉;空氣的溫度、濕度、焓值與熱舒適性[N];中國(guó)建設(shè)報(bào);2013年

3 薛世山;三能態(tài)低碳集成衛(wèi)浴房[N];中國(guó)建設(shè)報(bào);2013年

4 本報(bào)記者 薛秀春;沐浴新時(shí)代 節(jié)能新奉獻(xiàn)[N];中國(guó)建設(shè)報(bào);2013年

相關(guān)博士學(xué)位論文 前5條

1 王潤(rùn)澤;高危生物污染環(huán)境下主動(dòng)凈化送風(fēng)式正壓生物防護(hù)服的使用安全性與熱舒適性研究[D];中國(guó)人民解放軍軍事醫(yī)學(xué)科學(xué)院;2016年

2 端木琳;桌面工位空調(diào)系統(tǒng)室內(nèi)熱環(huán)境與熱舒適性研究[D];大連理工大學(xué);2007年

3 向立平;空調(diào)客車(chē)內(nèi)氣流分布特性及動(dòng)態(tài)熱舒適性研究[D];中南大學(xué);2011年

4 郭春梅;天津地區(qū)辦公建筑自然通風(fēng)熱舒適性研究[D];天津大學(xué);2010年

5 張文燦;汽車(chē)乘坐空間熱環(huán)境與乘員熱舒適性分析關(guān)鍵技術(shù)研究[D];華南理工大學(xué);2013年

相關(guān)碩士學(xué)位論文 前10條

1 王鑫;基于膠原纖維微觀三維構(gòu)象的皮革服裝濕熱舒適性研究[D];陜西科技大學(xué);2015年

2 張亞峰;高溫干燥地區(qū)開(kāi)放式站臺(tái)空調(diào)狀態(tài)下熱環(huán)境評(píng)價(jià)與改善[D];西南交通大學(xué);2014年

3 李武剛;冬季高校教室熱舒適性控制方法研究[D];西安建筑科技大學(xué);2015年

4 張盟;滲透式FADS控制的環(huán)境流場(chǎng)和溫度場(chǎng)數(shù)值模擬及熱舒適性預(yù)測(cè)[D];浙江理工大學(xué);2016年

5 趙林林;基于人體熱舒適性的汽車(chē)空調(diào)除霜性能研究[D];上海工程技術(shù)大學(xué);2016年

6 何良;車(chē)室內(nèi)流場(chǎng)和溫度場(chǎng)的數(shù)值模擬與研究[D];上海工程技術(shù)大學(xué);2016年

7 陳城;夏熱冬暖地區(qū)綜合商場(chǎng)功能區(qū)冬季熱舒適性研究[D];華南理工大學(xué);2016年

8 公丕健;客機(jī)地面作業(yè)中客艙溫濕度適宜性范圍研究[D];中國(guó)民航大學(xué);2016年

9 吳凡昊;空氣載能輻射末端應(yīng)用試驗(yàn)研究[D];湖南大學(xué);2015年

10 俞準(zhǔn);暫留區(qū)熱舒適性參數(shù)研究[D];華北電力大學(xué)(河北);2004年

,

本文編號(hào):2421306

資料下載
論文發(fā)表

本文鏈接:http://sikaile.net/jingjilunwen/jianzhujingjilunwen/2421306.html


Copyright(c)文論論文網(wǎng)All Rights Reserved | 網(wǎng)站地圖 |

版權(quán)申明:資料由用戶d2742***提供,本站僅收錄摘要或目錄,作者需要?jiǎng)h除請(qǐng)E-mail郵箱bigeng88@qq.com