熱適應控制模式的秋季試驗研究
發(fā)布時間:2019-01-06 19:37
【摘要】:在南方秋季典型日開展試驗研究,綜合比較了常規(guī)、熱適應和熱適應(夜間通風)3種室內(nèi)環(huán)境控制模式在物理參數(shù)、人員主觀反應和建筑能耗等方面的性能。結(jié)果顯示:與常規(guī)模式相比,熱適應模式能顯著提高室內(nèi)溫濕度和風速,降低CO_2濃度,在保持或改善人員環(huán)境滿意度的前提下實現(xiàn)節(jié)能,室內(nèi)空氣環(huán)境調(diào)節(jié)日均總能耗降低77%;如增加夜間通風功能,則可保證日間熱環(huán)境在舒適范圍而不必開啟空調(diào),室內(nèi)空氣環(huán)境調(diào)節(jié)日均總能耗降低96%。
[Abstract]:An experimental study was carried out on a typical autumn day in southern China. The performances of three indoor environmental control modes, namely, conventional, thermal and thermal adaptation (night ventilation), were compared in physical parameters, subjective reaction of personnel and building energy consumption. The results show that the thermal adaptation mode can significantly improve indoor temperature, humidity and wind speed, reduce the concentration of CO_2, and achieve energy saving under the premise of maintaining or improving the environmental satisfaction of personnel. The total daily energy consumption of indoor air environment was reduced by 77. If the night ventilation function is added, the daytime thermal environment can be ensured to be in comfortable range without the need to turn on the air conditioning, and the total daily energy consumption of indoor air conditioning can be reduced by 96%.
【作者單位】: 華南理工大學亞熱帶建筑科學國家重點實驗室;清華大學室內(nèi)空氣質(zhì)量評價與控制北京市重點實驗室;西安建筑科技大學;
【基金】:華南理工大學亞熱帶建筑科學國家重點實驗室資助課題(編號:x2jz/C715028z)
【分類號】:TU834
[Abstract]:An experimental study was carried out on a typical autumn day in southern China. The performances of three indoor environmental control modes, namely, conventional, thermal and thermal adaptation (night ventilation), were compared in physical parameters, subjective reaction of personnel and building energy consumption. The results show that the thermal adaptation mode can significantly improve indoor temperature, humidity and wind speed, reduce the concentration of CO_2, and achieve energy saving under the premise of maintaining or improving the environmental satisfaction of personnel. The total daily energy consumption of indoor air environment was reduced by 77. If the night ventilation function is added, the daytime thermal environment can be ensured to be in comfortable range without the need to turn on the air conditioning, and the total daily energy consumption of indoor air conditioning can be reduced by 96%.
【作者單位】: 華南理工大學亞熱帶建筑科學國家重點實驗室;清華大學室內(nèi)空氣質(zhì)量評價與控制北京市重點實驗室;西安建筑科技大學;
【基金】:華南理工大學亞熱帶建筑科學國家重點實驗室資助課題(編號:x2jz/C715028z)
【分類號】:TU834
【參考文獻】
相關(guān)期刊論文 前3條
1 王昭俊;孫曉利;趙加寧;劉京;;利用夜間通風改善辦公建筑熱環(huán)境的實驗研究[J];哈爾濱工業(yè)大學學報;2006年12期
2 李崢嶸,陳沛霖;晚間通風及其與蒸發(fā)冷卻技術(shù)的聯(lián)合應用[J];同濟大學學報(熱能工程版);1995年06期
3 傅祥釗;長江流域間歇通風住宅外墻熱工研究[J];住宅科技;1995年02期
【共引文獻】
相關(guān)期刊論文 前10條
1 麥錦博;張明揚;張宇峰;王福林;翟永超;;熱適應控制模式的秋季試驗研究[J];暖通空調(diào);2016年12期
2 何立斌;;辦公建筑的天然采光試驗研究[J];科技與企業(yè);2016年09期
3 李楠;楊柳;朱小波;;西安地區(qū)辦公建筑夜間通風降溫實驗研究[J];暖通空調(diào);2015年04期
4 張洪宇;莊春龍;鄧安仲;沈小東;;夜間通風量對相變輕質(zhì)房間室內(nèi)熱環(huán)境的影響[J];后勤工程學院學報;2014年02期
5 趙文學;安峗剛;;西部地域辦公建筑自然通風的節(jié)能效應研究[J];磚瓦;2014年02期
6 馮國會;韓淑伊;劉馨;黃凱良;李慧星;;相變墻房間夏季夜間通風效果實驗[J];沈陽建筑大學學報(自然科學版);2013年04期
7 王漢青;李端茹;王lǚ,
本文編號:2403239