新建建筑圍護(hù)結(jié)構(gòu)熱濕耦合動(dòng)態(tài)特性試驗(yàn)及數(shù)值研究

發(fā)布時(shí)間:2018-03-25 19:57

  本文選題:建筑節(jié)能 切入點(diǎn):新建建筑圍護(hù)結(jié)構(gòu) 出處:《長安大學(xué)》2016年碩士論文


【摘要】:隨著能源問題的不斷突出、建筑能耗占社會(huì)總能耗比重的不斷增長,建筑節(jié)能成為世界各國關(guān)注的熱點(diǎn)問題。目前我國建筑節(jié)能措施主要考慮的是圍護(hù)結(jié)構(gòu)傳熱量對(duì)建筑能耗的影響,常常用傳熱系數(shù)的大小作為判斷圍護(hù)結(jié)構(gòu)是否達(dá)到節(jié)能要求的主要標(biāo)準(zhǔn),其中并沒有考慮濕分的影響。然而由于建筑圍護(hù)結(jié)構(gòu)材料多為多孔介質(zhì),其在建成初期孔隙中極易存在濕分,墻體內(nèi)部熱量傳遞與濕分傳輸相互影響,具有強(qiáng)耦合性。含濕量不同時(shí)其傳熱方式不同,材料的導(dǎo)熱系數(shù)也會(huì)隨之發(fā)生變化。因此研究建筑圍護(hù)結(jié)構(gòu)熱濕耦合傳輸過程十分必要,它對(duì)圍護(hù)結(jié)構(gòu)的熱工性能、建筑能耗及對(duì)建筑物本身都有著重大的影響。本論文針對(duì)新建建筑的圍護(hù)結(jié)構(gòu)進(jìn)行熱濕耦合動(dòng)態(tài)特性研究。采用原位試驗(yàn)與數(shù)值模擬相結(jié)合的方法,通過試驗(yàn)和數(shù)值計(jì)算結(jié)果分析,研究了西安市新建建筑外圍護(hù)結(jié)構(gòu)溫度、體積含濕量隨時(shí)間的變化情況,以及濕度變化過程中的有效傳熱系數(shù)的大小變化。在原位場(chǎng)地搭建了試驗(yàn)獨(dú)立房屋,在其內(nèi)部安裝了熱、濕檢測(cè)系統(tǒng)及熱流計(jì)系統(tǒng),跟蹤檢測(cè)圍護(hù)結(jié)構(gòu)的溫、濕度,定期檢測(cè)其傳熱系數(shù),并實(shí)時(shí)檢測(cè)了該原位場(chǎng)地周圍氣候參數(shù)。選取可靠的測(cè)試方法對(duì)圍護(hù)結(jié)構(gòu)材料的熱物性參數(shù)進(jìn)行了實(shí)驗(yàn)室標(biāo)定。通過試驗(yàn)得到了大量的有價(jià)值的試驗(yàn)數(shù)據(jù)。在此基礎(chǔ)上,以實(shí)驗(yàn)測(cè)定結(jié)果及原位場(chǎng)地氣候參數(shù)作為數(shù)學(xué)模型建立的基礎(chǔ)條件,運(yùn)用CHAMPS軟件建立了墻體熱、濕耦合動(dòng)態(tài)分析計(jì)算模型,并應(yīng)用建立好的墻體模型進(jìn)行了1~2年的模擬計(jì)算。通過原位試驗(yàn)和數(shù)值模擬計(jì)算得到結(jié)論,墻體溫度的傳遞具有衰減性和滯后性;新建房屋自建成至竣工后264天,各圍護(hù)結(jié)構(gòu)體積含濕量在自然條件下逐漸減少,不同朝向的同類墻體以及不同類型墻體,其體積含濕量下降率有所不同,多孔磚墻加氣混凝土墻鋼筋混凝土墻體;同種類型北向墻體濕度下降率大于東向墻體。各類保溫墻體的傳熱系數(shù)由于保溫層受潮先增加然后呈逐漸下降趨勢(shì),且實(shí)際傳熱系數(shù)始終高于干燥狀態(tài)下的理論計(jì)算值。利用CHAMPS軟件對(duì)該房屋鋼筋混凝土北墻2年預(yù)測(cè)計(jì)算后發(fā)現(xiàn),該新建建筑圍護(hù)結(jié)構(gòu)體積含濕量的變化是一個(gè)復(fù)雜的、反復(fù)的周期性過程,呈先下降后上升的變化規(guī)律;2年后該墻體的有效傳熱系數(shù)分別減少為理論傳熱系數(shù)的1.12倍、1.21倍。本課題的研究,為建筑圍護(hù)結(jié)構(gòu)保溫性能的正確評(píng)價(jià)提供了幫助。
[Abstract]:As the energy problem becomes more and more prominent, the proportion of building energy consumption in the total energy consumption of society is increasing. Building energy conservation has become a hot issue all over the world. At present, the influence of heat transfer of envelope structure on building energy consumption is the main consideration of building energy saving measures in our country. The magnitude of heat transfer coefficient is often used as the main criterion to judge whether the envelope structure meets the requirements of energy saving, and the influence of moisture content is not considered. However, the materials of building envelope structure are mostly porous media. It is easy to have wet fractionation in the pore in the initial stage of its completion. The heat transfer and moisture transfer inside the wall have mutual influence, and have strong coupling property. The heat transfer modes are different with different moisture content at the same time. Therefore, it is necessary to study the thermal-moisture coupling transmission process of the building envelope structure, which is of great importance to the thermal performance of the enclosure structure. The energy consumption of the building has a great influence on the building itself. In this paper, the thermal-moisture coupling dynamic characteristics of the new building envelope are studied. The method of in-situ test and numerical simulation is adopted. Based on the analysis of experimental and numerical results, the temperature and volume moisture content of the surrounding structure of newly built buildings in Xi'an are studied with time. As well as the change of effective heat transfer coefficient in the process of humidity change. A test independent house was built in the in-situ site, and a heat and humidity detection system and a heat flow meter system were installed inside the building to track and detect the temperature and humidity of the envelope structure. The heat transfer coefficient is measured regularly, The surrounding climatic parameters of the in-situ site were measured in real time. The thermal physical parameters of the enclosure structure materials were calibrated by a reliable test method. A large number of valuable experimental data were obtained through the experiments. On the basis of this, a large number of valuable experimental data were obtained. Based on the experimental results and in situ site climatic parameters as the basic condition of mathematical model, the dynamic analysis and calculation model of wall thermal and wet coupling is established by using CHAMPS software. The results of in-situ test and numerical simulation show that the transfer of wall temperature is attenuated and delayed, and the new building is built from completion to 264 days after completion. The volume moisture content of each retaining structure decreases gradually under the natural condition. The volume moisture content of the similar wall with different orientation and different types of wall is different, and the volume moisture content of porous brick wall is different. The reinforced concrete wall of aerated concrete wall of porous brick wall is different. The decrease rate of humidity of the same type of north wall is greater than that of the east wall. The heat transfer coefficient of all kinds of insulation wall increases first and then decreases gradually because of the moisture of the insulation layer. And the actual heat transfer coefficient is always higher than the theoretical calculation value under the dry state. After 2 years' prediction calculation of the reinforced concrete north wall of the building by using CHAMPS software, it is found that the change of the volume moisture content of the new building envelope structure is complicated. After two years, the effective heat transfer coefficient of the wall is reduced to 1.12 times and 1.21 times of the theoretical heat transfer coefficient respectively. It is helpful for the correct evaluation of thermal insulation performance of building enclosure.
【學(xué)位授予單位】:長安大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2016
【分類號(hào)】:TU111.4

【相似文獻(xiàn)】

相關(guān)期刊論文 前10條

1 李莉萍 ,徐宗平;挑戰(zhàn)傳統(tǒng)觀念的多功能圍護(hù)結(jié)構(gòu)[J];太陽能;2003年06期

2 王菲;肖勇全;;建筑圍護(hù)結(jié)構(gòu)的動(dòng)態(tài)熱平衡模型及實(shí)例分析[J];建筑熱能通風(fēng)空調(diào);2005年05期

3 陳仰真;;冷庫圍護(hù)結(jié)構(gòu)的節(jié)能研究[J];冷藏技術(shù);2008年02期

4 于水;張旭;;圍護(hù)結(jié)構(gòu)內(nèi)熱濕耦合數(shù)值模擬分析[J];建筑節(jié)能;2010年07期

5 王瑩瑩;劉艷峰;劉加平;;多孔圍護(hù)結(jié)構(gòu)熱濕耦合傳遞過程研究及進(jìn)展[J];建筑科學(xué);2011年06期

6 朱求源;徐新華;樸在元;;內(nèi)嵌管式圍護(hù)結(jié)構(gòu)的節(jié)能效果研究[J];建筑科學(xué);2011年12期

7 劉長兵;;重慶地區(qū)既有建筑圍護(hù)結(jié)構(gòu)改造淺析[J];建設(shè)科技;2013年01期

8 歐長貴;;建筑圍護(hù)結(jié)構(gòu)的節(jié)能研究[J];中國建筑金屬結(jié)構(gòu);2013年06期

9 韓兵正;盧華;;建筑圍護(hù)結(jié)構(gòu)傳熱性能的檢測(cè)技術(shù)分析[J];門窗;2013年09期

10 李仲英;;建筑降溫與圍護(hù)結(jié)構(gòu)隔熱要求之間的關(guān)系[J];硅酸鹽建筑制品;1976年Z1期

相關(guān)會(huì)議論文 前10條

1 蔣云峰;;外圍護(hù)結(jié)構(gòu)對(duì)空調(diào)負(fù)荷影響的模擬計(jì)算[A];全國暖通空調(diào)制冷2010年學(xué)術(shù)年會(huì)資料集[C];2010年

2 劉向峰;沈天行;;透明蓄水圍護(hù)結(jié)構(gòu)技術(shù)原理分析[A];綠色建筑與建筑物理——第九屆全國建筑物理學(xué)術(shù)會(huì)議論文集(二)[C];2004年

3 馮雅;;吸濕相變材料在建筑圍護(hù)結(jié)構(gòu)中的應(yīng)用[A];加入WTO和中國科技與可持續(xù)發(fā)展——挑戰(zhàn)與機(jī)遇、責(zé)任和對(duì)策(下冊(cè))[C];2002年

4 霍巖;赫崇軒;;環(huán)境試驗(yàn)室圍護(hù)結(jié)構(gòu)的計(jì)算機(jī)模批研究[A];全國暖通空調(diào)制冷1990年學(xué)術(shù)年會(huì)論文集(下)[C];1990年

5 婁偉;劉慶;胡敏華;;外圍護(hù)結(jié)構(gòu)的潛熱傳遞初探[A];全國暖通空調(diào)制冷2006年學(xué)術(shù)年會(huì)論文集[C];2006年

6 嚴(yán)玢;趙彬;;通過建筑圍護(hù)結(jié)構(gòu)的顆粒穿透規(guī)律研究[A];全國暖通空調(diào)制冷2006學(xué)術(shù)年會(huì)資料集[C];2006年

7 傅秀章;吳雁;;住宅圍護(hù)結(jié)構(gòu)的隔熱性能指標(biāo)研究[A];建筑環(huán)境與建筑節(jié)能研究進(jìn)展——2007全國建筑環(huán)境與建筑節(jié)能學(xué)術(shù)會(huì)議論文集[C];2007年

8 陳友明;周娟;;建筑圍護(hù)結(jié)構(gòu)非穩(wěn)定傳熱計(jì)算的驗(yàn)證方法[A];全國暖通空調(diào)制冷2004年學(xué)術(shù)文集[C];2004年

9 譚偉;閆增峰;任俊;;利用相似性原理求解圍護(hù)結(jié)構(gòu)的熱濕耦合傳遞過程[A];城市化進(jìn)程中的建筑與城市物理環(huán)境:第十屆全國建筑物理學(xué)術(shù)會(huì)議論文集[C];2008年

10 楊文斐;叢曉春;王明紅;;建筑圍護(hù)結(jié)構(gòu)的節(jié)能設(shè)計(jì)及動(dòng)態(tài)模擬的應(yīng)用[A];山東省暖通空調(diào)制冷2007年學(xué)術(shù)年會(huì)論文集[C];2007年

相關(guān)重要報(bào)紙文章 前9條

1 張紅;北方建筑關(guān)注保溫 南方建筑重視遮陽[N];中國建材報(bào);2006年

2 ;建筑節(jié)能的相關(guān)術(shù)語[N];中華建筑報(bào);2006年

3 本報(bào)記者 王曦;技術(shù)創(chuàng)新與集成在生態(tài)建筑中的展示性應(yīng)用(接上期)[N];中華建筑報(bào);2011年

4 興旺;豬舍的隔熱降溫[N];陜西科技報(bào);2009年

5 上海市建筑科學(xué)院教授級(jí)高工 陸善后;建筑圍護(hù)結(jié)構(gòu)可節(jié)能25%[N];建筑時(shí)報(bào);2005年

6 ;保溫與隔熱有什么區(qū)別[N];房地產(chǎn)時(shí)報(bào);2004年

7 王曦;節(jié)能減排 建筑先行[N];中華建筑報(bào);2009年

8 ;為什么圍護(hù)結(jié)構(gòu)保溫 能有效避免出現(xiàn)結(jié)露鐡[N];房地產(chǎn)時(shí)報(bào);2004年

9 房報(bào)記者 郁放煉;給老房子穿“衣”節(jié)能延壽[N];房地產(chǎn)時(shí)報(bào);2010年

相關(guān)博士學(xué)位論文 前9條

1 孔凡紅;新建建筑圍護(hù)結(jié)構(gòu)干燥特性及其影響研究[D];哈爾濱工業(yè)大學(xué);2008年

2 張輝;低能耗建筑主動(dòng)動(dòng)態(tài)復(fù)合圍護(hù)結(jié)構(gòu)研究[D];華中科技大學(xué);2011年

3 周娟;建筑圍護(hù)結(jié)構(gòu)動(dòng)態(tài)傳熱模擬方法的研究[D];湖南大學(xué);2012年

4 于靖華;基于EETP指標(biāo)的夏熱冬冷地區(qū)居住建筑圍護(hù)結(jié)構(gòu)熱工性能及經(jīng)濟(jì)性研究[D];湖南大學(xué);2009年

5 王瑩瑩;圍護(hù)結(jié)構(gòu)濕遷移對(duì)室內(nèi)熱環(huán)境及空調(diào)負(fù)荷影響關(guān)系研究[D];西安建筑科技大學(xué);2013年

6 朱求源;內(nèi)嵌管式圍護(hù)結(jié)構(gòu)熱特性理論分析與實(shí)驗(yàn)研究[D];華中科技大學(xué);2014年

7 劉念武;軟土地區(qū)支護(hù)墻平面及空間變形特性與開挖環(huán)境效應(yīng)分析[D];浙江大學(xué);2015年

8 徐曉麗;建筑外圍護(hù)結(jié)構(gòu)熱分析及人工冷源智能控制系統(tǒng)研究[D];天津大學(xué);2007年

9 鐘輝智;多孔建筑材料熱濕物理性能研究及應(yīng)用[D];西南交通大學(xué);2011年

相關(guān)碩士學(xué)位論文 前10條

1 高瓊e,

本文編號(hào):1664616


資料下載
論文發(fā)表

本文鏈接:http://sikaile.net/jingjilunwen/jianzhujingjilunwen/1664616.html


Copyright(c)文論論文網(wǎng)All Rights Reserved | 網(wǎng)站地圖 |

版權(quán)申明:資料由用戶8ec02***提供,本站僅收錄摘要或目錄,作者需要?jiǎng)h除請(qǐng)E-mail郵箱bigeng88@qq.com