多地塊地下公共通道消防設(shè)計初探
發(fā)布時間:2018-06-28 19:20
本文選題:城市綜合體 + 地下公共通道。 參考:《消防科學(xué)與技術(shù)》2015年12期
【摘要】:探討地下公共通道的消防設(shè)計要點,以20 MW火災(zāi)為基礎(chǔ)推算出地塊功能為商業(yè)和汽車庫時的通道寬度分別不得小于10m和4m。提出防火墻與防火門相結(jié)合、防火玻璃加噴淋保護(hù)、設(shè)置防火卷簾的防火分隔形式;建議區(qū)域規(guī)劃時在地下通道兩側(cè)各地塊合適區(qū)域預(yù)留疏散樓梯的位置;提出滅火系統(tǒng)、排煙系統(tǒng)及報警系統(tǒng)的設(shè)置要求及建議。
[Abstract]:The main points of fire protection design of underground public passage are discussed. Based on the 20 MW fire, the width of the passage should not be less than 10m and 4m respectively when the function of the plot is commercial and the car depot. It is proposed that firewalls should be combined with fire-proof doors, fire-proof glass and sprinkler protection should be added, fire prevention curtain should be set up to prevent fire separation, that evacuation staircases should be reserved in suitable areas on both sides of underground passageways in regional planning, and that fire extinguishing systems should be put forward. Requirements and suggestions for setting up smoke exhaust system and alarm system.
【作者單位】: 奧雅納工程咨詢(上海)有限公司;
【基金】:上海市科學(xué)技術(shù)委員會科研計劃項目“城市綜合體安全疏散技術(shù)研究”(12231200802)
【分類號】:TU921;TU967