天堂国产午夜亚洲专区-少妇人妻综合久久蜜臀-国产成人户外露出视频在线-国产91传媒一区二区三区

當(dāng)前位置:主頁 > 管理論文 > 城建管理論文 >

基于低品位熱源再生溶液除濕方式的空調(diào)系統(tǒng)研究

發(fā)布時(shí)間:2018-01-05 23:28

  本文關(guān)鍵詞:基于低品位熱源再生溶液除濕方式的空調(diào)系統(tǒng)研究 出處:《江蘇大學(xué)》2014年博士論文 論文類型:學(xué)位論文


  更多相關(guān)文章: 復(fù)合空調(diào)系統(tǒng) 除濕性能 再生溫度 參數(shù)配置 能耗模擬


【摘要】:暖通空調(diào)系統(tǒng)的舒適性和能耗問題日益受到重視,對(duì)傳統(tǒng)冷凍除濕空調(diào)系統(tǒng)提出了新的挑戰(zhàn)。傳統(tǒng)空調(diào)系統(tǒng)為了除濕需要將空氣處理到露點(diǎn)狀態(tài),既增加了壓縮機(jī)的耗功,又降低了空氣的舒適度,不能完全適應(yīng)當(dāng)今社會(huì)對(duì)空調(diào)系統(tǒng)的要求。目前以濕度控制為突破口,國內(nèi)外研究者提出了一些新的空氣調(diào)節(jié)方式和系統(tǒng)。 本文從傳質(zhì)動(dòng)力角度利用理論和實(shí)驗(yàn)手段研究了LiCl溶液除濕和再生過程。試驗(yàn)測(cè)試了傳統(tǒng)冷凍除濕空調(diào)機(jī)組的變工況運(yùn)行特性。在上述理論分析和試驗(yàn)結(jié)果的基礎(chǔ)上,設(shè)計(jì)了低品位熱源再生的小型溶液除濕復(fù)合空調(diào)系統(tǒng),并分析了系統(tǒng)能耗情況。 從理論角度,基于溶液除濕過程傳質(zhì)動(dòng)力的分析,依據(jù)LiCl溶液和濕空氣的物性參數(shù)關(guān)系,編程計(jì)算了等溫除濕過程的平衡曲線。在假設(shè)水蒸氣凝結(jié)潛熱全部進(jìn)入溶液中的條件下,計(jì)算了溶液溫升平衡曲線。以溶液和空氣進(jìn)口溫度為25℃、30℃和35℃為例,將溫升平衡曲線和與之對(duì)應(yīng)的等溫除濕平衡曲線比較發(fā)現(xiàn),兩者差距隨溶液濃度降低而減小,而且進(jìn)口溫度越高,兩者差距越明顯。 開展了LiCl溶液除濕試驗(yàn)研究。試驗(yàn)結(jié)果表明:凝結(jié)熱主要引起溶液溫升;除濕量隨空氣流量增加而增加,并非隨溶液流量單調(diào)增加;當(dāng)滿足空氣和溶液充分接觸條件時(shí),除濕效率隨空氣流量增加而降低;除濕效率隨溶液流量的變化類似于除濕量隨溶液流量的變化特點(diǎn)。通過兩種高度的填料的除濕性能比較發(fā)現(xiàn),除濕量隨填料高度增加而增大,但總?cè)莘e傳質(zhì)系數(shù)減小。說明除濕過程同傳熱過程類似,存在入口段效應(yīng)。 LiCl溶液再生試驗(yàn)結(jié)果表明,再生效果隨溶液質(zhì)量濃度增加而下降。再生量隨溶液進(jìn)口溫度上升而增加,當(dāng)溶液進(jìn)口溫度低于50℃時(shí),再生效果較差。 為進(jìn)行復(fù)合空調(diào)系統(tǒng)熱泵機(jī)組變工況條件下的能效分析,試驗(yàn)研究了傳統(tǒng)冷凍除濕空調(diào)機(jī)組變工況運(yùn)行性能并獲得機(jī)組能效比隨蒸發(fā)溫度和冷凝溫度變化的修正系數(shù)。試驗(yàn)表明,室內(nèi)環(huán)境參數(shù)對(duì)制冷量和除濕量有明顯的影響。對(duì)于一定溫濕度環(huán)境,單位除濕量耗功與循環(huán)風(fēng)量呈二次曲線關(guān)系,具有極小值。濕度越大,該極值越小,而且向大風(fēng)量偏移。 基于熱濕獨(dú)立控制原理和上述理論分析和試驗(yàn)研究結(jié)果,提出了二次回風(fēng)兩級(jí)溶液除濕方案,設(shè)計(jì)了低品位熱源再生的小型溶液除濕復(fù)合空調(diào)系統(tǒng)。復(fù)合空調(diào)系統(tǒng)以保證出風(fēng)參數(shù)優(yōu)先,同時(shí)滿足溶液再生溫度和最大需熱量要求。為此,設(shè)計(jì)使用了兩臺(tái)小熱泵機(jī)組提供17℃高溫冷水用于冷卻空氣和溶液,同時(shí)通過調(diào)節(jié)冷凍水流量分配實(shí)現(xiàn)系統(tǒng)綜合能效比的最大化。 最后,以上海地區(qū)一三層別墅為例,分別建立了獨(dú)立風(fēng)冷熱泵空調(diào)系統(tǒng)、地源熱泵空調(diào)系統(tǒng)、復(fù)合空調(diào)系統(tǒng)的能耗分析模型。以夏季7、8兩月最大負(fù)荷作為機(jī)組選擇依據(jù),以除濕率基本相等為基礎(chǔ),分析比較了三類空調(diào)系統(tǒng)在運(yùn)行期間的送風(fēng)參數(shù)、除濕性能、機(jī)組能耗等。結(jié)果表明,復(fù)合空調(diào)系統(tǒng)以小溫差大風(fēng)量形式送風(fēng),在保證出風(fēng)溫度的條件下,出風(fēng)相對(duì)濕度降低,可以改善室內(nèi)舒適度。在溶液除濕部分再生器溶液進(jìn)口溫度按照52℃,換熱器效能按0.7設(shè)計(jì)時(shí),復(fù)合空調(diào)系統(tǒng)節(jié)能優(yōu)勢(shì)并不明顯。當(dāng)換熱器效能提高至0.8時(shí),綜合能效比平均提高0.22,有一定的節(jié)能優(yōu)勢(shì)。
[Abstract]:Comfort and energy consumption of HVAC system has received increasing attention, a new challenge to the traditional refrigeration dehumidification air conditioning system. The traditional air conditioning system for dehumidifying air treatment will need to dew point state, which not only increase the compressor power consumption and reduces the air comfort, can not fully meet the requirements of today's society on the air conditioning system. At present, the humidity control as a breakthrough, the domestic and foreign researchers put forward some new ways and the air conditioning system.
This paper from the perspective of dynamic mass transfer by theoretical and experimental methods to study the LiCl solution dehumidification and regeneration process. Test the changing working conditions of traditional refrigeration dehumidification air conditioning unit. Based on the theoretical analysis and experimental results, the design of small liquid desiccant air-conditioning system of regeneration of low grade heat source, and analyzes the system energy consumption.
From the angle of theory, analysis of dynamic transfer solution dehumidification process based on LiCl, according to the relationship between the solution and the physical parameters of wet air, programming to calculate the equilibrium curve of isothermal dehumidification process. Under the assumption that the water vapor condensation all go into solution under the condition of ascending temperature calculation. The equilibrium curve solution in solution and air inlet temperature 25 degrees, 30 degrees and 35 degrees as an example, the temperature rise of the equilibrium curve and the corresponding isothermal dehumidification equilibrium curve comparison, the difference decreases with the solution concentration decreased, and the inlet temperature is higher, the gap is more obvious.
Experiment was conducted to study the liquid desiccant LiCl. The experimental results show that the condensation heat is mainly caused by the solution temperature rise; dehumidification capacity increases with the increase of air flow rate increased, with the increase of the flow rate of solution is not monotone; when the air and solution of contact conditions, dehumidification efficiency decreases with the increase of air flow rate; dehumidification efficiency varies with the flow rate of solution is similar to the the dehumidification changes with the characteristics of solution flow. Through the dehumidifying performance of two kinds of the packing height comparison found that the dehumidification with the filling height increases, but the total volumetric mass transfer coefficient decreases. Simultaneous thermal process of dehumidification process is similar, there are entrance effect.
The results of LiCl solution regeneration test showed that the regeneration effect decreased with the increase of solution concentration. The amount of regeneration increased with the increase of inlet temperature. When the inlet temperature of solution was below 50 C, the regeneration effect was poor.
Analysis of heat pump air-conditioning system under the condition of energy efficiency, testing the traditional refrigeration dehumidification air conditioning unit operation performance and energy efficiency ratio correction coefficient with the variation of evaporation temperature and condensation temperature. The results show that the indoor environment parameters have obvious effects on the refrigerating and dehumidifying capacity for temperature and humidity. The environment, power consumption is two units of the dehumidification curve relation with circulating air, has the minimal value. The extreme humidity is bigger, smaller, and large volume to offset.
Heat and humidity independent control principle and the theoretical analysis and experimental results based on the proposed two return two solution dehumidification scheme, design of small liquid desiccant air conditioning system of recycled composite low grade heat source. The air-conditioning system to ensure air parameters satisfy the requirements of priority, and the maximum heat solution regeneration temperature. Therefore, design the use of two sets of small heat pump unit provides 17 degrees high temperature cold water for cooling air and solution, at the same time by maximizing the adjustment of chilled water flow allocation system of comprehensive energy efficiency.
Finally, the 13 storey villa in Shanghai as an example, the independent air cooled heat pump system are established respectively, ground source heat pump air-conditioning system. Energy consumption analysis model of hybrid air conditioning system with maximum load in the 7,8 as a unit selection according to two months, dehumidification rate substantially equal as the basis, analysis and comparison of wind parameters, send three kinds of air conditioning system during the operation of the dehumidifying performance, the energy consumption of the unit. The results show that the hybrid air conditioning system with small temperature air in large volume form, ensure the air temperature under the condition of air relative humidity decreases, can improve the indoor comfort. In the part of liquid desiccant regenerator according to the inlet solution temperature of 52 DEG C, the heat exchanger efficiency by 0.7 the design, energy-saving advantages of hybrid air conditioning system is not obvious. When the heat exchanger efficiency increased to 0.8, the comprehensive energy efficiency ratio of the average increase of 0.22, energy-saving advantage.

【學(xué)位授予單位】:江蘇大學(xué)
【學(xué)位級(jí)別】:博士
【學(xué)位授予年份】:2014
【分類號(hào)】:TU831

【相似文獻(xiàn)】

相關(guān)期刊論文 前10條

1 ;案例3大型商場(chǎng)空調(diào)系統(tǒng)的節(jié)能改造[J];中國科技信息;2001年16期

2 楊昌智,葉國棟;空調(diào)系統(tǒng)的作用點(diǎn)及其舒適性節(jié)能性探討[J];暖通空調(diào);2002年03期

3 阮國輝;某廣電中心空調(diào)系統(tǒng)運(yùn)行問題分析與探討[J];暖通空調(diào);2002年04期

4 ;大型商場(chǎng)空調(diào)系統(tǒng)的節(jié)能改造[J];工程設(shè)計(jì)CAD與智能建筑;2002年03期

5 徐勇,丁培森;淺談某大酒店空調(diào)系統(tǒng)改造[J];江蘇煤炭;2002年04期

6 ;典型節(jié)能案例解析 第3例 大型商場(chǎng)空調(diào)系統(tǒng)的節(jié)能改造[J];能源工程;2002年03期

7 馮旭東;淺談空調(diào)系統(tǒng)的循環(huán)冷卻水設(shè)計(jì)[J];給水排水;2003年07期

8 江億;“非典”問題引起的對(duì)今后空調(diào)系統(tǒng)方式的思考[J];暖通空調(diào);2003年03期

9 張寅平,趙彬,成通寶,楊瑞,羅曉熹,莫金漢,江億;空調(diào)系統(tǒng)生物污染防治方法概述[J];暖通空調(diào);2003年03期

10 王立群;一冶南方大廈空調(diào)系統(tǒng)[J];山西建筑;2003年06期

相關(guān)會(huì)議論文 前10條

1 盧超;徐兆華;;談空調(diào)系統(tǒng)的節(jié)能措施[A];河南省土木建筑學(xué)會(huì)2010年學(xué)術(shù)大會(huì)論文集[C];2010年

2 李永安;崔新陽;劉學(xué)來;尹綱領(lǐng);黎福民;徐萌;;毛細(xì)管平面輻射空調(diào)系統(tǒng)供冷特性的研究[A];全國暖通空調(diào)制冷2010年學(xué)術(shù)年會(huì)論文集[C];2010年

3 陳慧和;;水冷多聯(lián)空調(diào)系統(tǒng)的設(shè)計(jì)及應(yīng)用[A];2009年湖南省暖通空調(diào)制冷學(xué)術(shù)年會(huì)論文集[C];2009年

4 曹皇親;;帥鈴Ⅱ空調(diào)系統(tǒng)的匹配設(shè)計(jì)[A];2008年安徽省科協(xié)年會(huì)機(jī)械工程分年會(huì)論文集[C];2008年

5 朱偉峰;薛志峰;江億;;空調(diào)系統(tǒng)若干常見問題分析(2) 二 空調(diào)部分[A];全國暖通空調(diào)制冷2000年學(xué)術(shù)年會(huì)論文集[C];2000年

6 王東;田永健;;熱泵式VRV空調(diào)系統(tǒng)在某大型醫(yī)院建筑中的應(yīng)用總結(jié)[A];全國暖通空調(diào)制冷2002年學(xué)術(shù)年會(huì)資料集[C];2002年

7 張寶懷;王曉;施明恒;史敏;田旭東;張秀平;;VRV空調(diào)系統(tǒng)的特點(diǎn)和設(shè)計(jì)試驗(yàn)方法[A];第2屆中國家用/商用中央空調(diào)應(yīng)用技術(shù)研討會(huì)論文集[C];2003年

8 李忠;鄭瑞澄;何濤;;太陽能在建筑物供暖空調(diào)系統(tǒng)中的應(yīng)用[A];21世紀(jì)太陽能新技術(shù)——2003年中國太陽能學(xué)會(huì)學(xué)術(shù)年會(huì)論文集[C];2003年

9 張?zhí)靷?韓海濤;張吉光;;空調(diào)系統(tǒng)的節(jié)能措施[A];山東省第五屆制冷空調(diào)學(xué)術(shù)年會(huì)論文集[C];2004年

10 張玉梅;李洪欣;戎衛(wèi)國;;VRV空調(diào)系統(tǒng)的新風(fēng)設(shè)計(jì)探討[A];山東省第五屆制冷空調(diào)學(xué)術(shù)年會(huì)論文集[C];2004年

相關(guān)重要報(bào)紙文章 前10條

1 車望;環(huán)?照{(diào)系統(tǒng)3年后上市[N];中國汽車報(bào);2003年

2 劉傳書;溫濕度獨(dú)立調(diào)節(jié)空調(diào)系統(tǒng)應(yīng)用推廣聯(lián)盟成立[N];科技日?qǐng)?bào);2007年

3 本報(bào)駐上海記者 鄔國明 王建剛 通訊員 吳天寅;空調(diào)系統(tǒng)的節(jié)能運(yùn)用[N];中華建筑報(bào);2012年

4 特約記者 趙春林;節(jié)能環(huán)保供暖空調(diào)系統(tǒng)進(jìn)駐喀什[N];喀什日?qǐng)?bào)(漢);2008年

5 本報(bào)駐上海記者 鄔國明 王一淼 通訊員 吳天寅;空調(diào)系統(tǒng)的節(jié)能運(yùn)用[N];中華建筑報(bào);2011年

6 宋紹彩;優(yōu)化空調(diào)系統(tǒng) 力促建筑節(jié)能[N];政府采購信息報(bào);2008年

7 本報(bào)記者 黃穗誠邋通訊員 張浩東;VAV空調(diào)通風(fēng)系統(tǒng)安裝成功[N];廣東建設(shè)報(bào);2008年

8 李壽武;楊亞軍;心中的春天[N];中國航空?qǐng)?bào);2002年

9 尤順義;建筑節(jié)能大勢(shì)所趨 空調(diào)系統(tǒng)優(yōu)化成關(guān)鍵[N];中國電子報(bào);2008年

10 海燕;日本新型辦公樓空調(diào)系統(tǒng)開發(fā)成功[N];建筑報(bào);2000年

相關(guān)博士學(xué)位論文 前10條

1 白建波;測(cè)試室空調(diào)系統(tǒng)自適應(yīng)控制的研究[D];東南大學(xué);2006年

2 孫洲陽;基于智能方法的蒸發(fā)型空調(diào)系統(tǒng)性能實(shí)驗(yàn)與優(yōu)選研究[D];天津大學(xué);2003年

3 項(xiàng)敬巖;基于及熱經(jīng)濟(jì)學(xué)的供熱空調(diào)系統(tǒng)分析與評(píng)價(jià)研究[D];天津大學(xué);2012年

4 張小芬;卷煙廠空調(diào)系統(tǒng)負(fù)荷特性及新型中央空調(diào)系統(tǒng)研究[D];東華大學(xué);2012年

5 周宴平;變頻多聯(lián)空調(diào)系統(tǒng)的能耗分析和實(shí)驗(yàn)研究[D];上海交通大學(xué);2008年

6 劉學(xué)來;毛細(xì)管格柵空調(diào)系統(tǒng)的動(dòng)態(tài)仿真與實(shí)驗(yàn)研究[D];中國石油大學(xué);2011年

7 丁靜;開式吸附式除濕輪空調(diào)系統(tǒng)的模擬與實(shí)驗(yàn)研究[D];華南理工大學(xué);1996年

8 李洪欣;全空氣集中空調(diào)新系統(tǒng)模式研究[D];同濟(jì)大學(xué);2007年

9 馬慶;辦公建筑空調(diào)系統(tǒng)用能優(yōu)化研究[D];山東大學(xué);2012年

10 何治斌;船舶空調(diào)系統(tǒng)的建模與仿真[D];大連海事大學(xué);2011年

相關(guān)碩士學(xué)位論文 前10條

1 李重石;深職院圖書館空調(diào)系統(tǒng)分析[D];華南理工大學(xué);2011年

2 何克青;自然供冷空調(diào)系統(tǒng)的節(jié)能分析與優(yōu)化控制策略研究[D];上海交通大學(xué);2012年

3 周廣;商住樓空調(diào)系統(tǒng)的運(yùn)行分析及系統(tǒng)優(yōu)化[D];華南理工大學(xué);2009年

4 楊臣;航站樓空調(diào)系統(tǒng)能耗分析與優(yōu)化控制策略研究[D];上海交通大學(xué);2011年

5 於仲義;變水量空調(diào)系統(tǒng)智能解耦控制研究[D];華中科技大學(xué);2004年

6 吳凌浩;新型蓄能除濕空調(diào)系統(tǒng)工作特性研究[D];大連理工大學(xué);2006年

7 陳啟;冷卻頂板空調(diào)系統(tǒng)的數(shù)值模擬與實(shí)驗(yàn)研究[D];天津大學(xué);2005年

8 許泳;太陽能驅(qū)動(dòng)的固體吸附式除濕空調(diào)系統(tǒng)研究[D];同濟(jì)大學(xué);2007年

9 劉巖;自然冷資源輔助空調(diào)系統(tǒng)研究[D];東北農(nóng)業(yè)大學(xué);2007年

10 湯天平;VRV空調(diào)系統(tǒng)全年能耗模擬[D];青島理工大學(xué);2010年



本文編號(hào):1385343

資料下載
論文發(fā)表

本文鏈接:http://sikaile.net/guanlilunwen/chengjian/1385343.html


Copyright(c)文論論文網(wǎng)All Rights Reserved | 網(wǎng)站地圖 |

版權(quán)申明:資料由用戶4a9f9***提供,本站僅收錄摘要或目錄,作者需要?jiǎng)h除請(qǐng)E-mail郵箱bigeng88@qq.com