不同劑量前門(mén)控心臟冠狀動(dòng)脈多層螺旋CT成像的比較
[Abstract]:Objective to compare the imaging quality and radiation dose of multislice spiral CT in cardiac coronary artery with different dose prospective gated axial scan. Methods A total of 80 patients undergoing prospective gated axial scanning were randomly divided into two groups: 40 patients in each group and 120 kV / 100m As as low dose group. In 120kV / 200m As group, the images were processed by professionals after multi-slice spiral CT scanning. The image quality and effective radiation dose were compared between the two groups. Results in the low dose group, the image quality was excellent in 30 cases and good in 10 cases, while in the routine dose group, the image quality was excellent in 31 cases and good in 9 cases. There was no significant difference in image quality between the two groups (P0.05). There was no significant difference in SNR,CNR between the two groups (P0.05), and ED in the low dose group (1.71 鹵0.18) m Sv) was significantly lower than that in the conventional dose group (2.86 鹵0.44) m Sv,) (P0.01). Conclusion the quality of low dose prospective gated axial scanning is similar to that of conventional dose imaging, but it can significantly reduce the radiation dose of the patients, which is worthy of clinical application.
【作者單位】: 湖北省荊州市第二人民醫(yī)院CT室;
【分類號(hào)】:R816.2;R541.4
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 趙漢英,張平,翟凌云;多層螺旋CT心臟冠狀動(dòng)脈成像技術(shù)應(yīng)用[J];云南醫(yī)藥;2005年03期
2 呂濱;;多排螺旋CT心臟冠狀動(dòng)脈成像的臨床應(yīng)用[J];中國(guó)醫(yī)刊;2006年02期
3 曲岷;;雙源螺旋CT在心臟冠狀動(dòng)脈成像中的應(yīng)用研究[J];實(shí)用醫(yī)技雜志;2007年03期
4 黃業(yè)成;;多排螺旋CT在心臟冠狀動(dòng)脈成像中的臨床診斷研究進(jìn)展[J];實(shí)用醫(yī)技雜志;2013年09期
5 劉治邦 ,唐伯訥;心臟冠狀動(dòng)脈直接手術(shù)后的強(qiáng)化治療[J];重慶醫(yī)藥;1978年05期
6 陳福星;;你知道嗎?[J];右江衛(wèi)生;1978年02期
7 王宗盛;周勝利;黃連慶;吳華連;;多排螺旋CT在心臟冠狀動(dòng)脈成像中的臨床應(yīng)用價(jià)值[J];井岡山醫(yī)專學(xué)報(bào);2008年03期
8 黃葵;;128層螺旋CT心臟冠狀動(dòng)脈成像中優(yōu)化掃描參數(shù)的研究[J];亞太傳統(tǒng)醫(yī)藥;2012年02期
9 連淑蘭;;保護(hù)心血管 每天來(lái)“一點(diǎn)”[J];武當(dāng);2012年08期
10 何強(qiáng),丁仕義,黎川,戴明德,胡珊珊;16層螺旋CT心臟冠狀動(dòng)脈成像技術(shù)評(píng)估[J];第三軍醫(yī)大學(xué)學(xué)報(bào);2004年21期
相關(guān)會(huì)議論文 前1條
1 何建軍;魯曉賀;羅金濤;熊宏柯;荀燕萍;張毅軍;;提高心臟冠狀動(dòng)脈造影圖像質(zhì)量的研究[A];全國(guó)醫(yī)學(xué)影像技術(shù)學(xué)術(shù)會(huì)議(CMIT-2004)論文匯編[C];2004年
相關(guān)重要報(bào)紙文章 前4條
1 慧君;老年人除冰箱霜須謹(jǐn)慎[N];衛(wèi)生與生活報(bào);2003年
2 何德功;人造紅血球可望治療腦血栓[N];醫(yī)藥經(jīng)濟(jì)報(bào);2004年
3 鐘易;舌下含藥最宜半臥[N];中國(guó)消費(fèi)者報(bào);2004年
4 楊春;舌下含藥應(yīng)半臥[N];中國(guó)消費(fèi)者報(bào);2002年
相關(guān)碩士學(xué)位論文 前1條
1 張帆;16排螺旋CT心臟冠狀動(dòng)脈血管造影技術(shù)的質(zhì)量控制與臨床應(yīng)用研究[D];第一軍醫(yī)大學(xué);2006年
,本文編號(hào):2303960
本文鏈接:http://sikaile.net/yixuelunwen/yundongyixue/2303960.html