肺動(dòng)脈CTA低對(duì)比劑用量掃描方法的探討
[Abstract]:Objective to explore the method and effect of pulmonary artery CTA low contrast dose scanning. Methods 57 patients with pulmonary artery CTA were selected as the observation objects, and 320 mg I / m l), was injected through the median elbow vein with a double-tube high pressure syringe. Results and conclusion the process of pulmonary artery CTA was performed by means of small dose group injection test scanning technique, and compared with the threshold automatic trigger scanning mode, the blindness was effectively avoided and the success rate of examination was improved. At the same time, it not only reduces the dosage of contrast agent accepted by patients, reduces the damage of nephrotoxicity, but also saves the cost of examination.
【作者單位】: 廣西桂東人民醫(yī)院影像科;
【分類號(hào)】:R816.2;R563.5
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 劉凡;韓向君;;降低肝臟增強(qiáng)CT掃描中對(duì)比劑用量的應(yīng)用進(jìn)展[J];海南醫(yī)學(xué);2013年20期
2 趙磊;趙俏靜;王希林;張偉;邵廣瑞;;在多排螺旋CT冠脈成像中適當(dāng)降低對(duì)比劑用量及注射速率[J];山東大學(xué)學(xué)報(bào)(醫(yī)學(xué)版);2008年08期
3 何新華;胡永勝;楊越;王自勇;巢惠民;付旋;費(fèi)長(zhǎng)軍;;不同對(duì)比劑用量方案在雙源CT冠狀動(dòng)脈成像及心臟結(jié)構(gòu)顯示方面的研究[J];中國(guó)中西醫(yī)結(jié)合影像學(xué)雜志;2013年02期
4 鄧斯亮;史永江;甄杰;葉禮新;;320層容積CT超低對(duì)比劑用量在鎖骨下動(dòng)脈CTA中的應(yīng)用[J];中國(guó)醫(yī)藥指南;2012年32期
5 康德強(qiáng);趙晶;苗忠;王玲璞;彭楠;華海琴;;應(yīng)用低管電壓掃描降低64排CT冠狀動(dòng)脈成像對(duì)比劑用量的研究[J];臨床放射學(xué)雜志;2014年05期
6 梁文學(xué);王飛;楊鴻英;王勇;;經(jīng)橈動(dòng)脈非選擇性腎動(dòng)脈造影優(yōu)勢(shì)的臨床研究[J];實(shí)用醫(yī)學(xué)雜志;2012年13期
7 楊先宏;柳澄;高飛;李寧;孫珊珊;;雙源CT低對(duì)比劑用量腎動(dòng)脈能量掃描的可行性研究[J];醫(yī)學(xué)影像學(xué)雜志;2013年05期
8 胡毅;于寰;張鐵;;間接法下肢深靜脈CT成像中對(duì)比劑用量的探討[J];中國(guó)CT和MRI雜志;2014年01期
9 康德強(qiáng);趙晶;華海琴;彭楠;王玲璞;李勝鰲;;低管電壓掃描條件下個(gè)體化對(duì)比劑用量方案在冠狀動(dòng)脈CTA中的應(yīng)用[J];中國(guó)介入影像與治療學(xué);2014年09期
10 趙磊;邵廣瑞;張偉;李朝華;;64排螺旋CT冠狀動(dòng)脈成像對(duì)比劑用量的初步探討[J];實(shí)用放射學(xué)雜志;2008年05期
相關(guān)會(huì)議論文 前4條
1 余亞平;張躍珍;張華;魏志軒;楊如平;;冠脈CTA的體會(huì)[A];2009中華醫(yī)學(xué)會(huì)影像技術(shù)分會(huì)第十七次全國(guó)學(xué)術(shù)大會(huì)論文集[C];2009年
2 王振;肖華偉;丁忠祥;袁建華;狄幸波;徐健;陳福華;張玉江;;640層CT冠狀動(dòng)脈成像對(duì)比劑用量對(duì)冠狀靜脈竇的影響[A];中華醫(yī)學(xué)會(huì)第十八次全國(guó)放射學(xué)學(xué)術(shù)會(huì)議論文匯編[C];2011年
3 徐健;陳軍法;沈駿;文陽(yáng);張玉江;;320排CT顱頸血管一站式成像低對(duì)比劑用量可行性研究[A];2013年浙江省放射學(xué)學(xué)術(shù)年會(huì)論文集[C];2013年
4 謝元亮;;64排CT冠狀動(dòng)脈成像個(gè)體化對(duì)比劑用量的優(yōu)化研究[A];中華醫(yī)學(xué)會(huì)第16次全國(guó)放射學(xué)學(xué)術(shù)大會(huì)論文匯編[C];2009年
相關(guān)碩士學(xué)位論文 前5條
1 馮曉蘭;低劑量迭代重建聯(lián)合低對(duì)比劑用量在頭顱CTA中的應(yīng)用價(jià)值[D];四川醫(yī)科大學(xué);2015年
2 肖太星;多層螺旋CT“雙低”掃描在冠狀動(dòng)脈成像中的臨床應(yīng)用[D];山東大學(xué);2016年
3 趙磊;多排螺旋CT冠狀動(dòng)脈成像中降低對(duì)比劑用量的初步研究[D];山東大學(xué);2008年
4 楊先宏;雙源CT低對(duì)比劑用量腎動(dòng)脈能量掃描的可行性研究[D];泰山醫(yī)學(xué)院;2013年
5 徐海峰;CTAP中對(duì)比劑用量及掃描延遲時(shí)間的實(shí)驗(yàn)研究[D];山西醫(yī)科大學(xué);2003年
,本文編號(hào):2271454
本文鏈接:http://sikaile.net/yixuelunwen/yundongyixue/2271454.html