低管電壓多層螺旋CT評(píng)估膽道支架惡性梗阻
[Abstract]:Objective To find a method to diagnose malignant biliary obstruction and reduce the dose of abdominal spiral CT scan, and to evaluate the image quality and radiation dose of low-tube voltage (100 K Vp) multi-slice spiral CT enhanced scan for malignant biliary obstruction in metallic biliary stents. All patients with highly suspected recurrence of malignant obstruction after expandable metallic biliary stent implantation underwent three-phase dynamic contrast-enhanced CT scan with high resolution. The CT images of portal vein phase were reconstructed with curved surface. The CT values of 184 layers were measured. The reconstructed image quality of 140 kVp and 100 kVp tube voltages was analyzed and compared. Results When the tube voltage decreased from 140 kVp to 100 kVp, the image noise increased from (19.88.62) HU to (24.22.24) HU (P 0.001), while CNR and FOM improved by 15% and 50% respectively. Tissue-liver CNR and low-tube voltage CT have practical value in displaying malignant obstructive tissue in metal stents.
【作者單位】: 中國(guó)醫(yī)學(xué)科學(xué)院 協(xié)和醫(yī)學(xué)院 北京協(xié)和醫(yī)院放射科;海口市人民醫(yī)院放射科;
【基金】:海南省自然科學(xué)基金項(xiàng)目(813261) ?谑兄攸c(diǎn)計(jì)劃項(xiàng)目(2012-075)
【分類號(hào)】:R657.4;R816.5
【共引文獻(xiàn)】
相關(guān)期刊論文 前1條
1 袁肖娜;高知玲;朱凱;馬文東;陳勇;;低劑量結(jié)合iDose迭代重建算法在上腹CT掃描中的應(yīng)用[J];上海交通大學(xué)學(xué)報(bào)(醫(yī)學(xué)版);2015年09期
【二級(jí)參考文獻(xiàn)】
相關(guān)期刊論文 前1條
1 周智鵬;張輝陽;邱維加;曾陽東;陳德勤;尹本德;徐軍紅;蘇壽紅;;64排螺旋CT軸掃節(jié)段掃描對(duì)降低腹部CT檢查輻射劑量的作用[J];廣東醫(yī)學(xué);2012年07期
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 臧晨宏;張敬;張?jiān)仆?;自動(dòng)毫安低管電壓技術(shù)在頭頸部血管造影中應(yīng)用的可行性研究[J];天津醫(yī)科大學(xué)學(xué)報(bào);2010年02期
2 唐坤;曹國(guó)全;李瑞;鄭祥武;吳恩福;翁傳政;;低管電壓腹部CT掃描對(duì)圖像質(zhì)量及輻射劑量影響的體模實(shí)驗(yàn)[J];中國(guó)醫(yī)學(xué)影像技術(shù);2012年04期
3 王一民;曹建新;楊誠;陶偉;黃毅;余婷婷;;低管電壓對(duì)頭部減影CTA圖像質(zhì)量和輻射劑量的影響[J];臨床放射學(xué)雜志;2011年01期
4 胡瑩瑩;孫宏亮;王玉麗;王武;;采用低管電壓技術(shù)和低劑量對(duì)比劑行256層螺旋CT頭頸部動(dòng)脈成像的可行性[J];中國(guó)醫(yī)學(xué)影像技術(shù);2012年07期
5 鐘偉清;劉衛(wèi)東;張翼;;低管電壓CT檢查的實(shí)驗(yàn)研究[J];中國(guó)中西醫(yī)結(jié)合影像學(xué)雜志;2012年04期
6 T.Nakaura;K.Awai;N.Maruyama;N.Takata;I.Yoshinaka;K.Harada;李瓊;;256層螺旋CT低劑量對(duì)比劑低管電壓高管電流掃描方案在腎功能衰竭病人腹部動(dòng)態(tài)增強(qiáng)掃描中的臨床應(yīng)用[J];國(guó)際醫(yī)學(xué)放射學(xué)雜志;2012年01期
7 李瑞;唐坤;林潔;鄭祥武;曹國(guó)全;;低管電壓低劑量腦CTA掃描對(duì)顱內(nèi)動(dòng)脈瘤的診斷價(jià)值[J];溫州醫(yī)學(xué)院學(xué)報(bào);2013年09期
8 趙承琳;王照謙;賈崇富;楊志強(qiáng);孫喜霞;盧曉娟;劉興眾;鄭飛;申敬順;;低管電壓迭代重建冠狀動(dòng)脈CT成像的圖像質(zhì)量和輻射劑量[J];中華老年心腦血管病雜志;2014年03期
9 杜煜;時(shí)高峰;王亞寧;;探討雙源CT頸動(dòng)脈造影低管電壓掃描的可行性[J];中國(guó)醫(yī)學(xué)影像技術(shù);2012年11期
10 王敏;李劍;;低管電壓技術(shù)在腹主動(dòng)脈及下肢動(dòng)脈CT成像中的可行性研究[J];中國(guó)醫(yī)學(xué)計(jì)算機(jī)成像雜志;2014年01期
相關(guān)會(huì)議論文 前3條
1 王棟;李劍;;雙源CT肺動(dòng)脈的低劑量成像技術(shù)[A];2010中華醫(yī)學(xué)會(huì)影像技術(shù)分會(huì)第十八次全國(guó)學(xué)術(shù)大會(huì)論文集[C];2010年
2 晏子旭;;低管電壓在雙源CT冠狀動(dòng)脈成像的應(yīng)用[A];2009中華醫(yī)學(xué)會(huì)影像技術(shù)分會(huì)第十七次全國(guó)學(xué)術(shù)大會(huì)論文集[C];2009年
3 唐坤;鄭祥武;李瑞;林潔;;80kV低管電壓掃描對(duì)腦CTA圖像質(zhì)量及輻射劑量影響的臨床研究[A];2012年浙江省放射學(xué)術(shù)年會(huì)論文集[C];2012年
相關(guān)碩士學(xué)位論文 前10條
1 馬晶晶;雙低CTPA及PE生化指標(biāo)的相關(guān)研究[D];河北醫(yī)科大學(xué);2015年
2 韓智明;64排CT低管電壓、低濃度對(duì)比劑掃描模式在頸部CTA檢查中的應(yīng)用研究[D];寧夏醫(yī)科大學(xué);2015年
3 李瑛;低對(duì)比劑劑量聯(lián)合低管電壓及高管電流技術(shù)在腎透明細(xì)胞癌MSCT檢查中的可行性研究[D];山西醫(yī)科大學(xué);2015年
4 王玉屏;低管電壓、低濃度碘對(duì)比劑(雙低)在頭頸CTA檢g械撓τ醚芯縖D];安徽醫(yī)科大學(xué);2015年
5 謝曉宇;128層螺旋CT低管電壓技術(shù)在頭部減影CTA中降低輻射劑量的臨床應(yīng)用研究[D];瀘州醫(yī)學(xué)院;2013年
6 宋照亮;128層螺旋CT低管電壓技術(shù)在下肢血管疾病中的應(yīng)用價(jià)值[D];山東大學(xué);2014年
7 趙承琳;低管電壓迭代重建適應(yīng)性序列冠狀動(dòng)脈CT成像的圖像質(zhì)量和輻射劑量研究[D];大連醫(yī)科大學(xué);2013年
8 臧晨宏;CT掃描頭頸血管造影中應(yīng)用自動(dòng)毫安低管電壓技術(shù)的研究[D];天津醫(yī)科大學(xué);2009年
9 藍(lán)嵐;顱腦DE-CTA掃描中低管電壓圖像的質(zhì)量評(píng)價(jià)[D];山東大學(xué);2012年
10 侯朝華;MDCTA自動(dòng)毫安低管電壓在診斷下肢閉塞性動(dòng)脈硬化癥中的應(yīng)用價(jià)值[D];天津醫(yī)科大學(xué);2011年