冠狀動脈CT成像中冠狀動脈追蹤凍結(jié)技術(shù)的價值
[Abstract]:Aim: to investigate the effect of coronary artery tracking freezing technique (SSF) on motion artifact of coronary artery CT under different heart rate. Methods: a total of 113 patients with suspected coronary heart disease were examined with Discovery CT 750 HD Freedom for coronary CTA. The images were reconstructed by standard algorithm (STD) and SSF algorithm. Likert 4 scores were used as the scoring criteria by two physicians. The image quality of coronary artery branching and segmental level was independently interpreted by random double blind method. According to the standard of heart rate during scanning, the patients were divided into 6 groups. The image quality scores of different reconstruction methods in the same heart rate group were compared by rank sum test, and the discriminative comparison was made by chi-square test. Results: all heart rate group SSF algorithm reconstructed image quality in anterior descending branch and circumflex branch. There was no significant difference in image score between the two algorithms of left main coronary artery (P0. 05). The segmental score of SSF algorithm was significantly higher than that of STD algorithm (P 0.001). 3 groups of SSF algorithm could be judged. The legibility of the two algorithms in the two groups was significantly higher than that in the STD reconstruction image (P0.01). There was no significant difference between the two groups. There was no statistically significant difference between the two groups. The legibility of the reconstructed images of the SSF algorithm in the right coronary artery was significantly higher than that in the STD reconstruction images in each vessel of the right coronary artery (P0.01). Conclusion: compared with the standard algorithm, SSF can significantly improve the image quality of each heart rate group and improve the legibility of the high heart rate group image.
【作者單位】: 新疆醫(yī)科大學第一附屬醫(yī)院影像中心;
【基金】:新疆維吾爾自治區(qū)自然科學基金No.2015211C074~~
【分類號】:R816.2;R541.4
【相似文獻】
相關(guān)期刊論文 前10條
1 余潤明 ,呂子萌 ,胡秋炎 ,周偉 ,肖洪波 ,方向明 ,李業(yè)甫;中央型腰椎間盤突出癥牽引推拿治療療效與CT成像及唾液中單胺類神經(jīng)遞質(zhì)含量變化的關(guān)系[J];中醫(yī)正骨;2002年02期
2 覃智斌;張明;趙紹偉;;CT成像引導下經(jīng)皮穿刺椎體成形術(shù)治療老年椎體壓縮性骨折的臨床觀察[J];華夏醫(yī)學;2009年05期
3 施亞明;宗永忠;吳春陽;王斌;;CT成像和平板運動試驗與冠狀動脈造影的對比研究[J];臨床薈萃;2009年19期
4 黃科峰;朱安平;陳洪高;李作坤;黎穎;姜小平;黎昌華;宋君;;高清CT自適應(yīng)統(tǒng)計迭代重建技術(shù)降低冠狀動脈CT成像輻射劑量的研究[J];臨床軍醫(yī)雜志;2012年01期
5 李宏亮;謝良地;;冠狀動脈粥樣硬化的CT成像[J];中華高血壓雜志;2011年02期
6 劉再毅;吳恩福;鄭祥武;嚴志漢;葉彩兒;;胰周血管16層CT成像研究[J];溫州醫(yī)學院學報;2006年06期
7 李保磊;封亞;李俊江;;CT成像射束硬化校正方法研究[J];生命科學儀器;2007年09期
8 彭明辰,,白玫;應(yīng)用測微光度計測試CT標準體模膠片影像評估CT成像系統(tǒng)有關(guān)性能參數(shù)的方法[J];醫(yī)療設(shè)備信息;1995年05期
9 毛定飚;滑炎卿;吳昊;葛哠俊;張國楨;;常規(guī)冠狀動脈造影與冠狀動脈CT成像結(jié)果存在差異的原因[J];臨床放射學雜志;2008年09期
10 A.Gervaise;B.Osemont;S.Lecocq;A.Noel;E.Micard;J.Felblinger;馬聰;;在320排CT寬容積捕獲條件下應(yīng)用自適應(yīng)迭代劑量減低法改善CT成像質(zhì)量[J];國際醫(yī)學放射學雜志;2012年02期
相關(guān)會議論文 前3條
1 梅錦榮;;CT成像對肱骨髁間粉碎性骨折手術(shù)治療的意義[A];2013中國工程院科技論壇暨浙江省骨科學學術(shù)年會論文摘要集[C];2013年
2 雷子喬;余建明;劉永華;田志梁;孔祥闖;遲彬;朱樂;謝光明;;冠狀動脈雙源CT成像質(zhì)量影響因素的探討[A];2010中華醫(yī)學會影像技術(shù)分會第十八次全國學術(shù)大會論文集[C];2010年
3 王運來;廖雄飛;葛瑞剛;;加速器機載kV錐形束CT成像參數(shù)對空間分辨率的影響[A];中華醫(yī)學會放射腫瘤治療學分會六屆二次暨中國抗癌協(xié)會腫瘤放療專業(yè)委員會二屆二次學術(shù)會議論文集[C];2009年
相關(guān)重要報紙文章 前1條
1 曲鳳波 李春英;兩千米地層的CT成像[N];大慶日報;2009年
相關(guān)碩士學位論文 前7條
1 王琳;金納米棒的合成及其CT成像的實驗研究[D];天津醫(yī)科大學;2014年
2 劉華;任意軌跡的CT成像方法關(guān)鍵技術(shù)研究[D];中北大學;2015年
3 亓昌珍;子宮及卵巢血管CT成像研究及其初步臨床應(yīng)用[D];蘇州大學;2013年
4 高海英;能譜CT成像關(guān)鍵參數(shù)檢測技術(shù)研究[D];南方醫(yī)科大學;2015年
5 鮑曉輝;非負分解算法在CT成像中的應(yīng)用[D];北京交通大學;2011年
6 牛素捚;基于能譜濾波分離的彩色CT成像方法研究[D];中北大學;2015年
7 賈鑫鑫;寶石能譜CT成像在食管癌術(shù)前評估中的應(yīng)用研究[D];安徽醫(yī)科大學;2015年
本文編號:2246430
本文鏈接:http://sikaile.net/yixuelunwen/yundongyixue/2246430.html