能譜CT低管電壓對(duì)下肢血管成像圖像質(zhì)量及輻射劑量影響
[Abstract]:Objective: to investigate the effect of CT low tube voltage technique on image quality and radiation dose of lower extremity arterial imaging. Methods: Seventy-two patients with lower extremity CT angiography (CTA) were randomly divided into three groups. The voltage of the three groups was 120 kV / 100 kV and 80 kV respectively, and the other scanning parameters were the same. According to the original image and the maximum density projection (MIP) recombination image, the lower extremity arterial image quality of the three groups was evaluated, the CT value of blood vessel was measured, the signal-to-noise ratio (SNR) (SNR), was compared with the SNR (CNR) and the radiation dose accepted by the patients. Results the CT value of blood vessel in group C was the lowest in group C, and the difference among three groups was statistically significant (P 0.05). There was no significant difference among groups of image CNR,SNR (P0.05). The lowest dose of radiation in group C was the highest in group A (P 0.05). Compared with group A, CT dose index (CTDIvol),) dose length product (DLP) and effective dose (ED) in group C decreased 35.8and 34.4%, respectively, and 64.4%, respectively. The difference was statistically significant (P0.05). Conclusion: EDS CT lower limb angiography with low tube voltage scan can meet the needs of clinical diagnosis and can greatly reduce the radiation dose accepted by patients.
【作者單位】: 安徽醫(yī)科大學(xué)第一附屬醫(yī)院放射科;
【分類號(hào)】:R543.5;R816.2
【參考文獻(xiàn)】
相關(guān)期刊論文 前4條
1 胡榮慧,宋光義,韓丹,許立奇,張良,成友華;螺旋CT檢測(cè)肺結(jié)節(jié)的低劑量?jī)?yōu)化選擇及應(yīng)用[J];放射學(xué)實(shí)踐;2005年07期
2 江時(shí)淦;洪春鳳;王豪;白雪冰;張譚俊雄;;眼眶部低劑量螺旋CT掃描參數(shù)的優(yōu)化[J];放射學(xué)實(shí)踐;2013年02期
3 彭謙;范淼;楊智云;孟悛非;;兒童副鼻竇結(jié)構(gòu)的64排CT低劑量技術(shù)應(yīng)用[J];影像診斷與介入放射學(xué);2008年02期
4 何青;賀文;;64排螺旋CT血管成像技術(shù)在下肢動(dòng)脈硬化閉塞癥中的應(yīng)用價(jià)值[J];中國(guó)醫(yī)學(xué)影像技術(shù);2009年08期
【共引文獻(xiàn)】
相關(guān)期刊論文 前10條
1 李曉明;田建明;王敏杰;蕭毅;郝強(qiáng);陸建平;李玉華;;64層螺旋CT血管成像評(píng)估下肢動(dòng)脈閉塞性疾病的合理旋轉(zhuǎn)時(shí)間及螺距[J];第二軍醫(yī)大學(xué)學(xué)報(bào);2010年02期
2 李好剛;褚玉靜;孫積;寧耿海;;雙源CT低劑量掃描技術(shù)在竇口鼻道復(fù)合體檢查中的應(yīng)用價(jià)值[J];中國(guó)醫(yī)藥科學(xué);2011年23期
3 陳仲平;;副鼻竇多層螺旋CT低劑量掃描的初步應(yīng)用[J];安徽醫(yī)學(xué);2012年07期
4 謝智峰;王順;周光榮;金光韋;黃佛生;冉容;韓波;;螺旋CT在檢測(cè)矽肺陰影的低劑量?jī)?yōu)化選擇[J];中國(guó)CT和MRI雜志;2012年04期
5 趙利娜;帥桃;彭濤;陳壢桃;李真林;;雙源CT雙能量成像在腦血管檢查中的應(yīng)用價(jià)值[J];放射學(xué)實(shí)踐;2013年12期
6 呂廷勇;馬炳蓮;黃子榮;王和斌;梁顯著;朱奉興;;CT低劑量掃描對(duì)新生兒缺血缺氧性腦病的診斷價(jià)值[J];包頭醫(yī)學(xué)院學(xué)報(bào);2013年05期
7 申敏;蔣蘊(yùn)毅;;低劑量CT結(jié)腸成像的研究進(jìn)展[J];國(guó)際醫(yī)學(xué)放射學(xué)雜志;2013年06期
8 陳國(guó)中;張龍江;周長(zhǎng)圣;祁麗;羅松;盧光明;;70kV管電壓在頭顱CT血管成像中的可行性[J];放射學(xué)實(shí)踐;2014年06期
9 吳爽;周長(zhǎng)圣;張龍江;顧海峰;祁麗;黃偉;;70kV低劑量CT血管成像在兒童胡桃?jiàn)A綜合征中的應(yīng)用[J];放射學(xué)實(shí)踐;2014年06期
10 李勰;祁麗;周長(zhǎng)圣;羅松;張龍江;盧光明;;雙源雙能量CT肺動(dòng)脈成像輻射劑量與圖像質(zhì)量的比較研究[J];放射學(xué)實(shí)踐;2014年09期
相關(guān)博士學(xué)位論文 前1條
1 李瓊;迭代重建技術(shù)在低劑量胸部CT中應(yīng)用的體模及臨床研究[D];第二軍醫(yī)大學(xué);2013年
相關(guān)碩士學(xué)位論文 前10條
1 趙一蓉;下肢動(dòng)脈硬化閉塞癥的MSCTA與DSA對(duì)照研究[D];成都中醫(yī)藥大學(xué);2010年
2 劉曉東;成人患者體型參數(shù)和腹部CT圖像質(zhì)量的關(guān)系以及個(gè)體化劑量調(diào)節(jié)的初步前瞻性研究[D];蘇州大學(xué);2007年
3 史學(xué)斌;下肢動(dòng)脈硬化閉塞癥的比較影像學(xué)研究[D];中國(guó)醫(yī)科大學(xué);2010年
4 應(yīng)琦;磁共振TRICKS在糖尿病足下肢血管病變中的診斷價(jià)值[D];浙江大學(xué);2012年
5 趙峰;多層螺旋CT胸部掃描技術(shù)與圖像噪聲及病變檢出相關(guān)性研究[D];重慶醫(yī)科大學(xué);2012年
6 郝永;下肢動(dòng)脈雙能CTA臨床應(yīng)用價(jià)值的研究[D];第三軍醫(yī)大學(xué);2012年
7 李芬;超聲對(duì)2型糖尿病下肢動(dòng)脈病變檢查及危險(xiǎn)因素相關(guān)性研究[D];廣西醫(yī)科大學(xué);2012年
8 韓偉;MSCTA對(duì)下肢動(dòng)脈硬化閉塞癥的應(yīng)用價(jià)值[D];泰山醫(yī)學(xué)院;2012年
9 涂永波;下肢動(dòng)脈疾病的多層螺旋CT血管成像研究及臨床應(yīng)用[D];瀘州醫(yī)學(xué)院;2011年
10 易孝純;MSCTA在下肢外傷及血栓閉塞性脈管炎中的臨床應(yīng)用[D];華中科技大學(xué);2012年
【二級(jí)參考文獻(xiàn)】
相關(guān)期刊論文 前10條
1 趙恒宇;葛欣然;王國(guó)鳳;;64-MSCT血管成像技術(shù)對(duì)動(dòng)脈測(cè)量的準(zhǔn)確性研究[J];白求恩軍醫(yī)學(xué)院學(xué)報(bào);2008年02期
2 李真林,楊志剛,余建群,易鳳群;肺部低劑量螺旋CT掃描的放射劑量評(píng)估[J];放射學(xué)實(shí)踐;2003年03期
3 陳偉,李文政,唐友林;螺旋CT圖像噪聲的評(píng)價(jià)[J];放射學(xué)實(shí)踐;2003年07期
4 吳曉華;胸部低劑量螺旋CT實(shí)驗(yàn)研究的進(jìn)展[J];國(guó)外醫(yī)學(xué)(臨床放射學(xué)分冊(cè));2004年01期
5 程良軍,郭鳴,龐太忠,張春卉;副鼻竇CT在內(nèi)窺鏡鼻竇手術(shù)中的作用[J];濟(jì)寧醫(yī)學(xué)院學(xué)報(bào);2005年01期
6 孔祥泉,韓萍,馮敢生;低劑量CT肺部掃描技術(shù)值得提倡與推廣[J];臨床放射學(xué)雜志;2003年07期
7 任慶云,何杰,王大軍,董玉龍;副鼻竇低劑量CT掃描的臨床研究[J];中國(guó)輻射衛(wèi)生;2005年02期
8 李珊珊;多層螺旋CT對(duì)下肢血管病變的診斷價(jià)值[J];實(shí)用醫(yī)學(xué)影像雜志;2005年01期
9 仲海,徐卓東,柳澄;CT血管成像技術(shù)在下肢動(dòng)脈疾病中的應(yīng)用價(jià)值[J];醫(yī)學(xué)影像學(xué)雜志;2004年12期
10 李源,,許庚;內(nèi)窺鏡鼻竇外科應(yīng)用解剖學(xué)[J];中華耳鼻咽喉科雜志;1994年05期
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 臧晨宏;張敬;張?jiān)仆?;自動(dòng)毫安低管電壓技術(shù)在頭頸部血管造影中應(yīng)用的可行性研究[J];天津醫(yī)科大學(xué)學(xué)報(bào);2010年02期
2 唐坤;曹國(guó)全;李瑞;鄭祥武;吳恩福;翁傳政;;低管電壓腹部CT掃描對(duì)圖像質(zhì)量及輻射劑量影響的體模實(shí)驗(yàn)[J];中國(guó)醫(yī)學(xué)影像技術(shù);2012年04期
3 王一民;曹建新;楊誠(chéng);陶偉;黃毅;余婷婷;;低管電壓對(duì)頭部減影CTA圖像質(zhì)量和輻射劑量的影響[J];臨床放射學(xué)雜志;2011年01期
4 胡瑩瑩;孫宏亮;王玉麗;王武;;采用低管電壓技術(shù)和低劑量對(duì)比劑行256層螺旋CT頭頸部動(dòng)脈成像的可行性[J];中國(guó)醫(yī)學(xué)影像技術(shù);2012年07期
5 鐘偉清;劉衛(wèi)東;張翼;;低管電壓CT檢查的實(shí)驗(yàn)研究[J];中國(guó)中西醫(yī)結(jié)合影像學(xué)雜志;2012年04期
6 T.Nakaura;K.Awai;N.Maruyama;N.Takata;I.Yoshinaka;K.Harada;李瓊;;256層螺旋CT低劑量對(duì)比劑低管電壓高管電流掃描方案在腎功能衰竭病人腹部動(dòng)態(tài)增強(qiáng)掃描中的臨床應(yīng)用[J];國(guó)際醫(yī)學(xué)放射學(xué)雜志;2012年01期
7 李瑞;唐坤;林潔;鄭祥武;曹國(guó)全;;低管電壓低劑量腦CTA掃描對(duì)顱內(nèi)動(dòng)脈瘤的診斷價(jià)值[J];溫州醫(yī)學(xué)院學(xué)報(bào);2013年09期
8 趙承琳;王照謙;賈崇富;楊志強(qiáng);孫喜霞;盧曉娟;劉興眾;鄭飛;申敬順;;低管電壓迭代重建冠狀動(dòng)脈CT成像的圖像質(zhì)量和輻射劑量[J];中華老年心腦血管病雜志;2014年03期
9 趙艷娥;張龍江;周長(zhǎng)圣;蘇宏;黃偉;顧海峰;朱正庭;盧光明;;雙源CT低管電壓冠狀動(dòng)脈成像技術(shù)的初步研究[J];臨床放射學(xué)雜志;2009年10期
10 杜煜;時(shí)高峰;王亞寧;;探討雙源CT頸動(dòng)脈造影低管電壓掃描的可行性[J];中國(guó)醫(yī)學(xué)影像技術(shù);2012年11期
相關(guān)會(huì)議論文 前3條
1 王棟;李劍;;雙源CT肺動(dòng)脈的低劑量成像技術(shù)[A];2010中華醫(yī)學(xué)會(huì)影像技術(shù)分會(huì)第十八次全國(guó)學(xué)術(shù)大會(huì)論文集[C];2010年
2 晏子旭;;低管電壓在雙源CT冠狀動(dòng)脈成像的應(yīng)用[A];2009中華醫(yī)學(xué)會(huì)影像技術(shù)分會(huì)第十七次全國(guó)學(xué)術(shù)大會(huì)論文集[C];2009年
3 唐坤;鄭祥武;李瑞;林潔;;80kV低管電壓掃描對(duì)腦CTA圖像質(zhì)量及輻射劑量影響的臨床研究[A];2012年浙江省放射學(xué)術(shù)年會(huì)論文集[C];2012年
相關(guān)碩士學(xué)位論文 前8條
1 謝曉宇;128層螺旋CT低管電壓技術(shù)在頭部減影CTA中降低輻射劑量的臨床應(yīng)用研究[D];瀘州醫(yī)學(xué)院;2013年
2 宋照亮;128層螺旋CT低管電壓技術(shù)在下肢血管疾病中的應(yīng)用價(jià)值[D];山東大學(xué);2014年
3 趙承琳;低管電壓迭代重建適應(yīng)性序列冠狀動(dòng)脈CT成像的圖像質(zhì)量和輻射劑量研究[D];大連醫(yī)科大學(xué);2013年
4 臧晨宏;CT掃描頭頸血管造影中應(yīng)用自動(dòng)毫安低管電壓技術(shù)的研究[D];天津醫(yī)科大學(xué);2009年
5 藍(lán)嵐;顱腦DE-CTA掃描中低管電壓圖像的質(zhì)量評(píng)價(jià)[D];山東大學(xué);2012年
6 侯朝華;MDCTA自動(dòng)毫安低管電壓在診斷下肢閉塞性動(dòng)脈硬化癥中的應(yīng)用價(jià)值[D];天津醫(yī)科大學(xué);2011年
7 葉瑾;雙源CT Flash螺旋掃描低管電壓冠狀動(dòng)脈成像的初步研究[D];新疆醫(yī)科大學(xué);2014年
8 王澍;低濃度碘克沙醇聯(lián)合低管電壓在下肢動(dòng)脈硬化閉塞癥CT血管成像中的應(yīng)用[D];蘇州大學(xué);2014年
本文編號(hào):2199857
本文鏈接:http://sikaile.net/yixuelunwen/yundongyixue/2199857.html