石墨烯修飾玻碳電極用于循環(huán)伏安法測定鹽酸表阿霉素
[Abstract]:Graphene was modified on the surface of glassy carbon electrode for the determination of epirubicin hydrochloride by cyclic voltammetry. In B-R buffer solution of pH 4.0, the oxidation peak of epirubicin hydrochloride was observed at -0.382 V at modified electrode, and the current of oxidation peak was more than twice as high as that at bare glassy carbon electrode. The oxidation peak current of epirubicin hydrochloride was linear to its concentration in the range of 1.0 脳 10-6 mol L-1, and the detection limit (3S/N) was 2.0 脳 10-9 mol L-1. The method was applied to the determination of epirubicin hydrochloride injection. The recoveries of epirubicin hydrochloride injection were 95.9% and 97.7% respectively. The relative standard deviation (nong 6) of the determination value was less than 2%.
【作者單位】: 山西大學化學化工學院;
【基金】:山西省青年科技基金項目(20021008)
【分類號】:R927.1;O657.1
【參考文獻】
相關(guān)期刊論文 前4條
1 龔曉麗;秦永平;梁茂植;余勤;南峰;;HPLC熒光和質(zhì)譜兩種檢測器測定大鼠血漿及組織中的表阿霉素[J];華西藥學雜志;2008年01期
2 賴麗燕;劉崢;袁帥;;石墨烯在生物傳感器中的應(yīng)用[J];理化檢驗(化學分冊);2013年03期
3 吳燕;張福成;吳誠;梅興國;呂萬良;;鹽酸表阿霉素長循環(huán)熱敏脂質(zhì)體大鼠藥代動力學考察[J];藥學學報;2010年03期
4 葉雪梅;林聰麗;湯從容;;循環(huán)伏安法測定輸液中表柔比星的含量[J];中國藥師;2011年05期
【共引文獻】
相關(guān)期刊論文 前10條
1 柴逸峰;朱臻宇;陳嘯飛;;藥物分析(Ⅱ)[J];分析試驗室;2010年10期
2 康輝;羅民;梁斌;竇元運;梁森;丁肖怡;;摻氮石墨烯的溶劑熱制備及對抗壞血酸氧化的電催化性能[J];功能材料;2013年18期
3 劉超;張萍;;鹽酸表柔比星藥理作用及含量測定研究進展[J];北方藥學;2014年05期
4 于小雯;石高全;;石墨烯/高分子復合薄膜的制備及應(yīng)用[J];高分子學報;2014年07期
5 龔雄輝;蔣圣偉;雷宇晴;潘平;汪學方;;石墨烯諧振器的研究進展[J];微納電子技術(shù);2014年09期
6 楊琳琳;李曦;王夢夢;閆松齡;劉信;李小雨;胡善洲;焦龍華;;電化學DNA傳感器的最新研究進展:電極修飾材料、探針固定方法和雜交信號檢測方法[J];材料導報;2014年19期
7 楊曉蕊;徐婧;馬麗娜;郭明;;石墨烯-殼聚糖修飾玻碳電極檢測牛奶中的三聚氰胺[J];大連大學學報;2014年06期
8 司曉晶;王欣s,
本文編號:2260042