FibroTouch在慢性肝病中臨床的應用及與多參數模型的比較
發(fā)布時間:2018-07-14 19:21
【摘要】:目的評估瞬時彈性超聲成像儀(FibroTouch)與多參數模型在慢性肝病患者肝臟纖維化診斷中的臨床應用價值及FibroTouch診斷肝纖維化分期的最佳診斷截點(cutoff)值。方法 2014年1月至2016年10月該院慢性肝病患者進行肝臟組織活檢48例,收集血常規(guī)、肝功能等血清學指標,同時應用FibroTouch進行肝臟彈性測量值(LSM)測量,分析LSM與肝臟纖維化的相關性,cutoff值與APRI、FIB-4、FibroIndex多參數模型診斷效能的比較。結果以肝臟穿刺病理結果為金標準,Spearman等級相關性分析提示LSM、APRI、FIB-4、FibroIndex多參數模型與肝纖維化相關(P0.05)。受試者工作特性曲線(ROC)分析,F1~F4期FibroTouch診斷肝纖維化分期的最佳cutoff值依次為6.6、7.7、10.5、15kPA;診斷有無顯著纖維化和肝硬化時的診斷價值優(yōu)于APRI、FIB-4、FibroIndex多參數模型。結論 FibroTouch在評估慢性肝病患者肝臟纖維化程度有較高的臨床應用價值。
[Abstract]:Objective to evaluate the clinical value of instantaneous elastic ultrasound imaging (FibroTouch) and multi-parameter model in the diagnosis of hepatic fibrosis in patients with chronic liver disease and to evaluate the optimal diagnostic point (cutoff) value of FibroTouch in the diagnosis of hepatic fibrosis stage. Methods from January 2014 to October 2016, liver tissue biopsy was performed in 48 patients with chronic liver disease in our hospital. Serum routine examination, liver function and other serological indexes were collected, and liver elasticity (LSM) was measured with FibroTouch. To analyze the correlation between LSM and hepatic fibrosis and compare the diagnostic efficacy of APRII-FIB-4 FibroIndex multiparameter model. Results the correlation analysis of Spearman grade with the pathological results of liver puncture suggested that the multiparameter model of FIB-4 FibroIndex of LSMN APRIX was related to liver fibrosis (P0.05). The optimal cutoff value of F1F4 FibroTouch in diagnosing hepatic fibrosis stage was 6.6 / 7.710.5 / 15kPA, and the diagnostic value of FIB-4 FibroIndex was better than that of APRII-FIB-4 FibroIndex. Conclusion FibroTouch has a high clinical value in evaluating the degree of liver fibrosis in patients with chronic liver disease.
【作者單位】: 江蘇省南通市第三人民醫(yī)院肝病科;
【基金】:江蘇省南通市衛(wèi)生和計劃委員會青年科研項目(WQ2015031) 江蘇省重點研發(fā)計劃(社會發(fā)展)重點病種規(guī)范化診療項目(BE2015655)
【分類號】:R575.2
本文編號:2122693
[Abstract]:Objective to evaluate the clinical value of instantaneous elastic ultrasound imaging (FibroTouch) and multi-parameter model in the diagnosis of hepatic fibrosis in patients with chronic liver disease and to evaluate the optimal diagnostic point (cutoff) value of FibroTouch in the diagnosis of hepatic fibrosis stage. Methods from January 2014 to October 2016, liver tissue biopsy was performed in 48 patients with chronic liver disease in our hospital. Serum routine examination, liver function and other serological indexes were collected, and liver elasticity (LSM) was measured with FibroTouch. To analyze the correlation between LSM and hepatic fibrosis and compare the diagnostic efficacy of APRII-FIB-4 FibroIndex multiparameter model. Results the correlation analysis of Spearman grade with the pathological results of liver puncture suggested that the multiparameter model of FIB-4 FibroIndex of LSMN APRIX was related to liver fibrosis (P0.05). The optimal cutoff value of F1F4 FibroTouch in diagnosing hepatic fibrosis stage was 6.6 / 7.710.5 / 15kPA, and the diagnostic value of FIB-4 FibroIndex was better than that of APRII-FIB-4 FibroIndex. Conclusion FibroTouch has a high clinical value in evaluating the degree of liver fibrosis in patients with chronic liver disease.
【作者單位】: 江蘇省南通市第三人民醫(yī)院肝病科;
【基金】:江蘇省南通市衛(wèi)生和計劃委員會青年科研項目(WQ2015031) 江蘇省重點研發(fā)計劃(社會發(fā)展)重點病種規(guī)范化診療項目(BE2015655)
【分類號】:R575.2
【相似文獻】
相關碩士學位論文 前2條
1 李生香;MRI同反相位減影法、FibroTouch受控衰減參數在脂肪肝定量診斷中的價值[D];延安大學;2016年
2 王艷紅;FibroTouch聯合血清學指標在非酒精性脂肪性肝病診斷中的應用研究[D];昆明醫(yī)科大學;2016年
,本文編號:2122693
本文鏈接:http://sikaile.net/yixuelunwen/xiaohjib/2122693.html
最近更新
教材專著