剩余電壓測試方法及其自動測量儀器的關(guān)鍵技術(shù)研究
本文選題:剩余電壓 + 峰值斷電 ; 參考:《中南大學(xué)》2012年碩士論文
【摘要】:剩余電壓是指用插頭連接電源的設(shè)備在拔掉插頭的瞬時,插頭上各插腳之間的殘余電壓,或者是當(dāng)斷開電氣設(shè)備電網(wǎng)供電的瞬間內(nèi)部儲能元件(如電容)上的殘余電壓。制定剩余電壓、剩余能量的限值是為了保護(hù)患者、操作者或其他人員的人身安全,防止在斷電瞬間觸及帶電部件而發(fā)生危險(xiǎn)。故準(zhǔn)確地檢測醫(yī)療設(shè)備的剩余電壓值具有十分重要的意義。 本文通過對現(xiàn)有剩余電壓的測試方法的研究,設(shè)計(jì)了一種新型剩余電壓自動測試儀,該測試儀由單片機(jī)組成的控制與數(shù)據(jù)處理單元及峰值檢測電路單元等組成。首先,給待測設(shè)備提供電源,峰值時刻檢測電路準(zhǔn)確找到電壓峰值點(diǎn),單片機(jī)發(fā)出信號控制繼電器驅(qū)動電路斷開電源,然后采用分壓器將電源插頭間的剩余電壓進(jìn)行分壓采樣,該采樣電壓輸入到電壓跟隨器,電壓跟隨器輸出的電壓值經(jīng)ADC后,輸入到單片機(jī)數(shù)據(jù)處理單元進(jìn)行數(shù)據(jù)處理、儲存與顯示,并在剩余電壓超出標(biāo)準(zhǔn)時報(bào)警。 本研究解決了剩余電壓測量的一個關(guān)鍵技術(shù)問題,即通過設(shè)計(jì)個零點(diǎn)檢測的關(guān)鍵電路與可調(diào)延時器的配合,能使設(shè)備在交流峰值處準(zhǔn)確斷電。該新型剩余電壓測量裝置,具有較好的重復(fù)性、穩(wěn)定性,以克服現(xiàn)有剩余電壓測試儀不能準(zhǔn)確地在峰值處斷電、測試重復(fù)性差、測試工作量大及不能顯示放電曲線等缺陷。
[Abstract]:The residual voltage refers to the instantaneous voltage between the pins of the plug and the residual voltage of the internal energy storage elements (such as capacitors) when the power supply of the electrical equipment is disconnected by the device connected with the power supply by the plug at the moment of unplugging the plug and the residual voltage between the pins on the plug. The limits of residual voltage and residual energy are set to protect the personal safety of patients, operators or other personnel, and to prevent danger from touching live components at the moment of power failure. Therefore, it is very important to accurately detect the residual voltage of medical equipment. In this paper, a new type of residual voltage automatic testing instrument is designed through the research of the existing residual voltage test method. The instrument is composed of a single chip microcomputer control and data processing unit and a peak detection circuit unit. First of all, to provide power to the equipment to be tested, the peak time detection circuit accurately find the voltage peak point, the single chip microcomputer sends out the signal to control the relay drive circuit to disconnect the power supply, and then uses the voltage divider to sample the remaining voltage between the power plugs. The sampling voltage is input to the voltage follower. After the output voltage value of the voltage follower is passed through ADC, it is input to the data processing unit of the single chip microcomputer for data processing, storage and display, and alarm when the remaining voltage exceeds the standard. In this paper, a key problem of residual voltage measurement is solved, that is, by designing the key circuit of zero point detection and the cooperation of adjustable delay device, the equipment can be cut off accurately at the peak value of AC. The new residual voltage measuring device has good repeatability and stability, so as to overcome the shortcomings of the existing residual voltage measuring instrument, such as not being able to power off accurately at the peak value, poor repeatability, large test workload and the inability to display the discharge curve.
【學(xué)位授予單位】:中南大學(xué)
【學(xué)位級別】:碩士
【學(xué)位授予年份】:2012
【分類號】:R318.6
【相似文獻(xiàn)】
相關(guān)會議論文 前6條
1 Stephan Hoffarth;;用PXI與LabVIEW測試高壓浪涌保護(hù)裝置[A];08全國電工測試技術(shù)學(xué)術(shù)交流會論文集[C];2008年
2 張慧;劉開培;秦亮;陳清泉;;選擇性諧波控制的通用優(yōu)化多電平PWM方法研究[A];2006中國電工技術(shù)學(xué)會電力電子學(xué)會第十屆學(xué)術(shù)年會論文摘要集[C];2006年
3 葉念國;;抑制變壓器勵磁涌流的新方法[A];2006中國電力系統(tǒng)保護(hù)與控制學(xué)術(shù)研討會論文集[C];2006年
4 從揚(yáng);;周波電壓跌落模擬器校準(zhǔn)的研究[A];江蘇省計(jì)量測試學(xué)術(shù)論文集(2010)[C];2010年
5 陳朝繁;;醫(yī)用電氣設(shè)備對電擊危險(xiǎn)的防護(hù)[A];2008年中華臨床醫(yī)學(xué)工程及數(shù)字醫(yī)學(xué)大會暨中華醫(yī)學(xué)會醫(yī)學(xué)工程學(xué)分會第九次學(xué)術(shù)年會論文集[C];2008年
6 陳清海;力一崢;郭良福;袁曉東;王成程;鄧武;李煒;周丕璋;;激光裝置新型能源系統(tǒng)技術(shù)改造[A];中國工程物理研究院科技年報(bào)(2003)[C];2003年
相關(guān)重要報(bào)紙文章 前4條
1 程茲;對自焙槽預(yù)焙化的建議[N];中國有色金屬報(bào);2002年
2 孫江;開拓?zé)o線 挑戰(zhàn)無限[N];中國電子報(bào);2001年
3 蘇州工藝美術(shù)職業(yè)技術(shù)學(xué)院 游仲華;簡單實(shí)用的充電器無極性連接裝置[N];電子報(bào);2009年
4 安徽 方坤;剖析雅格高亮度LED手提燈電路[N];電子報(bào);2009年
相關(guān)碩士學(xué)位論文 前2條
1 曹俐;剩余電壓測試方法及其自動測量儀器的關(guān)鍵技術(shù)研究[D];中南大學(xué);2012年
2 歐陽洵孜;基于雷達(dá)遙感測定海洋工程中潮位的技術(shù)應(yīng)用[D];大連海事大學(xué);2010年
,本文編號:2085573
本文鏈接:http://sikaile.net/yixuelunwen/swyx/2085573.html