M型Ti-Ni合金血管支架的結(jié)構(gòu)設(shè)計(jì)對(duì)性能的影響
發(fā)布時(shí)間:2018-06-15 19:50
本文選題:M型血管支架 + 結(jié)構(gòu)設(shè)計(jì); 參考:《稀有金屬》2017年08期
【摘要】:血管支架的支撐性能及回彈性能是支架在結(jié)構(gòu)設(shè)計(jì)過程中需要考慮的重要指標(biāo)。本文選取M型支架節(jié),通過有限元軟件模擬,探究M型支架節(jié)的高度變化及結(jié)構(gòu)設(shè)計(jì)波高比(h/H)對(duì)支架支撐性能及回彈性能的影響。結(jié)果顯示:相同h/H比值的M型結(jié)構(gòu)設(shè)計(jì),支架高度H值越小,支架支撐力越大;固定高度H值不變,隨著h/H比值增大,支架的支撐力減小,且在同一位移載荷下,減小程度隨h/H比值增大更顯著;當(dāng)h/H=1時(shí),M型支架轉(zhuǎn)變?yōu)閆型支架,此時(shí)支架的支撐力最小;不同h/H比值設(shè)計(jì)的M結(jié)構(gòu),在不同的位移載荷作用下支架的回彈率區(qū)別較大;以h/H=1/2為基準(zhǔn),h/H1/2的支架結(jié)構(gòu)較h/H1/2的支架結(jié)構(gòu)回彈率明顯高;在不同的位移載荷作用下,Z型支架較M型支架支撐性能較弱但回彈率穩(wěn)定。
[Abstract]:The support performance and springback performance of vascular stent are important indexes to be considered in the process of structural design. In this paper, M-type bracket is selected and simulated by finite element software to explore the influence of height change of M-shaped bracket and the effect of wave height ratio (H / H) on the support performance and springback performance of the bracket. The results show that the lower the support height H is, the greater the support force is in the design of M-type structure with the same H / H ratio, the fixed height H value is constant, and the supporting force decreases with the increase of H / H ratio, and under the same displacement load, the support force decreases with the increase of H / H ratio. When H / H = 1, the support force of the support is the smallest, and the springback rate of the M structure with different H / H ratio is different under different displacement loads. On the basis of h / H / 1 / 2, the support structure of H / H / H 1 / 2 is more resilient than that of H / H 1 / 2, and the support performance of Z type bracket is weaker than that of M type bracket under different displacement loads, but the springback rate is stable.
【作者單位】: 北京有色金屬研究總院有研億金新材料有限公司;
【基金】:國(guó)家自然科學(xué)基金項(xiàng)目(51401027)資助
【分類號(hào)】:R318.08;TG146.23
【相似文獻(xiàn)】
相關(guān)博士學(xué)位論文 前1條
1 劉小麗;血管支架用Mg-Zn-Y-Nd合金的體外生物相容性及表面改性研究[D];北京科技大學(xué);2015年
相關(guān)碩士學(xué)位論文 前4條
1 劉培玉;生物鎂合金血管支架的結(jié)構(gòu)設(shè)計(jì)與優(yōu)化[D];鄭州大學(xué);2015年
2 王俊;可降解血管支架用Mg-Zn-Y-Nd合金組織及性能研究[D];鄭州大學(xué);2010年
3 季川祥;血管支架用Mg-Zn-Y-Nd(-Zr)合金組織及性能研究[D];鄭州大學(xué);2014年
4 趙振心;TiNi合金血管支架的有限元分析及疲勞測(cè)試[D];上海交通大學(xué);2008年
,本文編號(hào):2023364
本文鏈接:http://sikaile.net/yixuelunwen/swyx/2023364.html
最近更新
教材專著