不同劑量308nm準分子光治療斑塊狀銀屑病療效分析
本文選題:銀屑病 切入點:光學 出處:《重慶醫(yī)學》2017年03期
【摘要】:目的評價不同起始劑量308nm準分子光治療斑塊狀銀屑病的療效及安全性。方法將94例銀屑病患者按隨機數(shù)字法分為小劑量組、中等劑量組和大劑量組,分別以1、3、6倍最小紅斑量起始劑量308nm準分子光照射,每周最多2次,療程8周。結(jié)果治療后2、4、6、8周小劑量組與中等劑量之間及治療后4、6、8周中等劑量組與大劑量組之間銀屑病皮損面積和嚴重程度指數(shù)(PASI)評分及皮膚生活質(zhì)量指數(shù)(DLQI)評分比較差異均有統(tǒng)計學意義(P0.05)。3組DLQI評分與PASI評分呈顯著正相關(guān)(r=0.826、0.835、0.861,P0.01),DLQI評分改善率與PASI評分改善率亦呈顯著正相關(guān)(r=0.845、0.851、0.896,P0.01)。大劑量組與其余兩組總有效率比較差異有統(tǒng)計學意義(χ~2=12.23、7.36,P0.05);中等劑量組同小劑量總有效率比較差異有統(tǒng)計學意義(χ~2=9.14,P0.05)。大劑量組較中等劑量組及小劑量組照射次數(shù)及總劑量少,治療后滿意度評分高(P0.05);中等劑量組較小劑量組照射次數(shù)及總劑量少,治療后滿意度評分高(P0.05)。大劑量及中等劑量組與小劑量組復發(fā)率比較差異有統(tǒng)計學意義(χ~2=10.58、7.64,P0.05)。結(jié)論大劑量308nm準分子光治療比小劑量療效好,對于總面積小且頑固的皮損,可選擇大劑量照射。
[Abstract]:Objective to evaluate the efficacy and safety of different initial doses of 308nm excimer light in the treatment of plaque psoriasis. The initial dose of 308nm excimer with a minimum erythema dose of 6 times 1 ~ 3 ~ 3 times was irradiated twice a week, respectively. Results the PASI and DLQI scores of psoriasis lesions were measured between the low-dose group and the medium-dose group and between the moderate dose group and the high-dose group at the 8th week after treatment and between the moderate dose group and the high dose group. The PASI score and the skin quality of life index (DLQI) score of psoriasis were obtained after 8 weeks of treatment. There was significant positive correlation between DLQI score and PASI score in group P0.053.There was significant positive correlation between the improvement rate of DLQI score and the improvement rate of PASI score. There was significant difference in the total effective rate between the high dose group and the other two groups. The total effective rate of medium dose group was significantly different from that of small dose group (蠂 ~ 2 / 2 ~ (9.14)) P _ (0.05). The radiation frequency and total dose of high dose group were less than those of medium dose group and small dose group. The total effective rate of high dose group was lower than that of medium dose group and small dose group. The total effective rate of high dose group was lower than that of medium dose group and small dose group. The satisfaction score after treatment was higher than that in the low dose group (P 0.05), and the radiation frequency and the total dose in the medium dose group were lower than those in the small dose group. There was a significant difference in the recurrence rate between the high dose and middle dose groups and the small dose group (蠂 2 10. 58% 7.64% P 0. 05). Conclusion High dose 308nm excimer light therapy is more effective than low dose 308nm excimer light therapy, and it can treat small and stubborn skin lesions with a total area. High dose irradiation can be selected.
【作者單位】: 西南醫(yī)科大學臨床醫(yī)學院;重慶三峽醫(yī)藥高等?茖W校附屬醫(yī)院皮膚科;重慶市第一人民醫(yī)院皮膚科;
【基金】:基金項目:重慶三峽醫(yī)藥高等專科學校2015-2016年度苗圃工程(2016mpxz13)
【分類號】:R758.63
【相似文獻】
相關(guān)期刊論文 前10條
1 夏家騮;陶平;張曉東;沈桂明;張書永;李華瀅;張子臣;田瓏;陳瓞延;文克玲;馬萬云;李良全;惠秦;吉望西;;準分子激光心肌血管重建的實驗研究[J];中國激光醫(yī)學雜志;1993年04期
2 陳風榮;馬麗;陳顏芳;陳明哲;黃南堂;康寧;徐積仁;;準分子激光誘導動脈熒光光譜的研究[J];中國激光醫(yī)學雜志;1992年02期
3 張超玲;;準分子層流手術(shù)室的管理[J];全科護理;2013年22期
4 鄭曉龍,王安;準分子激光屈光性角膜切削術(shù)前、后淚液β_2—微球蛋白的測定[J];臨床眼科雜志;1996年01期
5 桂星雨;章堅;;ESRIS準分子激光治療儀工作原理及故障維修[J];醫(yī)療裝備;2012年06期
6 沈建新,胡利剛,廖文和;準分子激光切削角膜的數(shù)學模型與切削技術(shù)研究[J];激光生物學報;2003年01期
7 張勇;項蕾紅;李劍;祝綠川;鄭志忠;;308 nm準分子光對人角質(zhì)形成細胞的凋亡、細胞周期和干細胞因子表達的影響[J];中華皮膚科雜志;2007年06期
8 戴超靚;柯勤飛;;準分子紫外光源對于血液過濾用非織造布表面改性的研究[J];產(chǎn)業(yè)用紡織品;2008年11期
9 吳建剛;馬飛;;眼科準分子激光治療機性能參數(shù)檢測[J];醫(yī)療衛(wèi)生裝備;2006年03期
10 蔡方榮;鄧智會;龔雪;;高度近視眼準分子激光原位角膜磨鑲術(shù)后療效觀察[J];中國實用醫(yī)藥;2011年12期
相關(guān)博士學位論文 前3條
1 莊曉波;氪—鹵素準分子紫外光源的特性研究[D];復旦大學;2010年
2 馮祥芬;準分子紫外光源及其降解廢水廢氣的研究[D];復旦大學;2005年
3 楊梅;準分子紫外輻射對紡織品的表面改性[D];東華大學;2010年
相關(guān)碩士學位論文 前3條
1 方雪慧;準分子燈光催化降解難降解有機污染物[D];江蘇理工學院;2016年
2 林蓮萍;準分子激光微加工像面定位及Z軸跟蹤系統(tǒng)的設(shè)計[D];北京工業(yè)大學;2016年
3 陳古源;納秒脈沖驅(qū)動準分子光源的實驗及模型研究[D];復旦大學;2011年
,本文編號:1686657
本文鏈接:http://sikaile.net/yixuelunwen/pifb/1686657.html