分布式地震數(shù)據(jù)采集同步技術(shù)研究
本文選題:分布式 + 地震數(shù)據(jù)采集; 參考:《西南科技大學(xué)》2017年碩士論文
【摘要】:地震勘探技術(shù)是石油勘探中有效的方法之一,地震勘探中的所使用的數(shù)據(jù)采集系統(tǒng)正朝著三分量、高密度、多道數(shù)、分布式的大規(guī)模數(shù)據(jù)采集方向發(fā)展,地震數(shù)據(jù)的采集同步性將直接關(guān)系到后續(xù)的地震資料處理與解釋工作的準(zhǔn)確性,在分布式地震數(shù)據(jù)采集系統(tǒng)中是一個重要且關(guān)鍵的因素。由于分布式地震采集系統(tǒng)中節(jié)點數(shù)的增多以及相互之間較為獨立,也給其實現(xiàn)數(shù)據(jù)的采集同步帶來了一定的難度。分布式系統(tǒng)中采集同步常用的是給數(shù)據(jù)加上時間戳的方法,其基本要求是需要各個節(jié)點的時鐘保持一致,傳統(tǒng)的網(wǎng)絡(luò)授時方法由于其節(jié)點數(shù)的增多,增加了網(wǎng)絡(luò)授時方法的復(fù)雜度及難度。針對上述問題,本文依托于"復(fù)雜山地多波寬頻帶地震數(shù)據(jù)采集系統(tǒng)研制"國家自然科學(xué)基金重大科研儀器設(shè)備研制專項支持,對分布式采集系統(tǒng)中的單節(jié)點數(shù)據(jù)采集同步、采集節(jié)點的時鐘同步的問題展開研究與設(shè)計。單節(jié)點數(shù)據(jù)采集同步研究與設(shè)計中,本文基于STM32F429ZET6低功耗高性能微處理器實現(xiàn)32位高精度地震數(shù)據(jù)采集節(jié)點設(shè)計,在單采樣間隔時間內(nèi)通過硬件SPI通信協(xié)議實現(xiàn)采集節(jié)點三分量數(shù)據(jù)的并行采集同步。設(shè)計完成32位A/D芯片ADS1282的轉(zhuǎn)換電路、采集電路、電源電路及相關(guān)下位機(jī)驅(qū)動程序的開發(fā),經(jīng)測試,單節(jié)點3路信號同步精度在2ns以內(nèi),信號線性相關(guān)度為99.99%,具有良好的同步水平。采集節(jié)點的時鐘同步研究與設(shè)計中,本文結(jié)合GPS時間無累計誤差、本地時鐘短短期的穩(wěn)定性較好的特點。設(shè)計完成基于GPS時鐘作為中心時鐘對采集節(jié)點進(jìn)行授時,同時利用其高精度的1PPS秒脈沖對本地時鐘頻率進(jìn)行測量與校準(zhǔn),降低本地時鐘漂移對時鐘走時帶來的誤差。設(shè)計完成基于GPS的本地授時系統(tǒng)相關(guān)軟硬件設(shè)計,對本地時鐘頻率測量、調(diào)整及時間戳生成方法進(jìn)行設(shè)計與實現(xiàn),經(jīng)測試,節(jié)點間GPS授時1PPS同步信號誤差為30ns以內(nèi),單節(jié)點時間戳誤差在0.1us以內(nèi),節(jié)點間時鐘誤差在10us以內(nèi)。通過本文的研究,為地震數(shù)據(jù)采集中的單節(jié)點數(shù)據(jù)采集同步以及多節(jié)點的時鐘同步的問題,研究并設(shè)計了一種有效的方法,為地震數(shù)據(jù)采集的同步問題提供了一種有效的解決途徑。
[Abstract]:Seismic exploration technology is one of the effective methods in petroleum exploration. The data acquisition system used in seismic exploration is developing towards the direction of large-scale data acquisition with three components, high density, multi-channel number and distributed data acquisition. The synchronization of seismic data acquisition is directly related to the accuracy of subsequent seismic data processing and interpretation. It is an important and key factor in distributed seismic data acquisition system. Since the number of nodes in distributed seismic acquisition system is increasing and each other is independent, it is difficult to realize the synchronization of data acquisition. The common method of collecting synchronization in distributed system is to add time stamp to the data. Its basic requirement is to keep the clock of each node consistent. The traditional network timing method is due to the increase of the number of nodes. The complexity and difficulty of the network timing method are increased. In view of the above problems, this paper relies on "the development of multi-wave broadband seismic data acquisition system in complex mountainous areas", which is supported by the National Natural Science Foundation of China for the development of major scientific research instruments and equipment, and synchronizes the single node data acquisition in the distributed acquisition system. Research and design of clock synchronization of acquisition node. In the research and design of single node data acquisition synchronization, the 32 bit high precision seismic data acquisition node is designed based on STM32F429ZET6 low power and high performance microprocessor. In the time of single sampling interval, the parallel acquisition synchronization of three component data is realized by hardware SPI communication protocol. The conversion circuit, acquisition circuit, power supply circuit and related lower computer driver of 32-bit A / D chip ADS1282 are designed and developed. After testing, the synchronization accuracy of single node 3-channel signal is within 2ns. The linear correlation of the signal is 99.99 and has a good synchronization level. In the research and design of clock synchronization of acquisition nodes, this paper combines the characteristics of GPS time with no accumulative error, and the local clock with short term stability. The timing of the acquisition node based on the GPS clock is designed and the local clock frequency is measured and calibrated by using its high precision 1PPS second pulse to reduce the error caused by the local clock drift. The software and hardware of the local time service system based on GPS are designed and completed. The method of local clock frequency measurement, adjustment and time stamp generation is designed and implemented. After testing, the error of GPS timing 1PPS synchronization signal between nodes is within 30ns. The time stamp error of single node is within 0.1us and the clock error between nodes is within 10us. Through the research of this paper, an effective method is studied and designed for single node data acquisition synchronization and multi-node clock synchronization in seismic data acquisition. It provides an effective way to solve the synchronization problem of seismic data acquisition.
【學(xué)位授予單位】:西南科技大學(xué)
【學(xué)位級別】:碩士
【學(xué)位授予年份】:2017
【分類號】:P631.4;TP274.2
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 李志武;;馬可賽斯1500系列地震數(shù)據(jù)采集系統(tǒng)[J];國外地質(zhì)勘探技術(shù);1983年03期
2 Carl Savit ,徐禮國;地震數(shù)據(jù)采集[J];地球物理學(xué)進(jìn)展;1990年02期
3 亢俊健,寧書年,趙建立;地震數(shù)據(jù)采集系統(tǒng)的監(jiān)控軟件設(shè)計與實現(xiàn)[J];計算機(jī)測量與控制;2003年02期
4 羅維炳;新型地震數(shù)據(jù)采集系統(tǒng)實現(xiàn)真正數(shù)字化的新臺階[J];石油儀器;2003年01期
5 吳俊松;地震數(shù)據(jù)采集系統(tǒng)內(nèi)部延遲及其測試[J];物探裝備;2005年02期
6 羅蘭兵;胡敬斌;;提高地震數(shù)據(jù)采集系統(tǒng)的電磁兼容性[J];石油儀器;2006年05期
7 羅福龍;;地震數(shù)據(jù)采集系統(tǒng)綜述和展望[J];中國石油勘探;2007年02期
8 廖聲剛;;408UL地震數(shù)據(jù)采集系統(tǒng)的地震區(qū)域網(wǎng)絡(luò)[J];物探裝備;2007年04期
9 劉益成;易碧金;鞏慶鋼;張顯桂;;地震數(shù)據(jù)采集系統(tǒng)相位特性與測試方法[J];石油物探;2009年02期
10 段昌平;劉益成;易碧金;;地震數(shù)據(jù)采集站增益精度測試方法[J];石油儀器;2010年02期
相關(guān)會議論文 前9條
1 馬建德;王桂華;楊麗娜;;海上地震數(shù)據(jù)采集參數(shù)選取方法研究[A];中國地球物理學(xué)會第二十屆年會論文集[C];2004年
2 陳俊良;;高分辨地震數(shù)據(jù)采集設(shè)備的設(shè)計[A];中國地震學(xué)會第四次學(xué)術(shù)大會論文摘要集[C];1992年
3 楊德義;王峗;邢春穎;;三分量地震數(shù)據(jù)采集中的微動信號監(jiān)控[A];2000年中國地球物理學(xué)會年刊——中國地球物理學(xué)會第十六屆年會論文集[C];2000年
4 廖聲剛;;電磁干擾與地震數(shù)據(jù)采集系統(tǒng)[A];湖北省石油學(xué)會第十一次優(yōu)秀學(xué)術(shù)論文評選會論文集[C];2004年
5 馬建德;;海上地震數(shù)據(jù)采集主要參數(shù)選取方法[A];第五次東海石油地質(zhì)研討會論文集[C];2004年
6 高磊;潘樹林;周熙襄;鐘本善;;基于初至?xí)r間的物理點位置自動檢查[A];中國地球物理學(xué)會第22屆年會論文集[C];2006年
7 李懷良;庹先國;杜勇;劉勇;朱麗麗;;基于無線通信技術(shù)的遙測式地震數(shù)據(jù)采集技術(shù)研究[A];中國地球物理學(xué)會第二十七屆年會論文集[C];2011年
8 高尚華;薛兵;蔣久明;鄒鎮(zhèn)宇;;高性能地震數(shù)據(jù)采集方案構(gòu)想[A];中國地震學(xué)會第14次學(xué)術(shù)大會專題[C];2012年
9 朱國維;王懷秀;彭蘇萍;;新型智能三分量地震檢波器的研制與應(yīng)用[A];煤礦安全與地球物理學(xué)術(shù)研討會論文集[C];2006年
相關(guān)重要報紙文章 前9條
1 周宏;中石油推新型地震數(shù)據(jù)采集記錄系統(tǒng)[N];地質(zhì)勘查導(dǎo)報;2010年
2 記者 孟可 通訊員 達(dá)成靈 蘇惠萍;北疆經(jīng)理部建立內(nèi)部公正競爭機(jī)制[N];中國石油報;2005年
3 記者 孟可;吐哈經(jīng)理部技術(shù)創(chuàng)新實現(xiàn)三項突破[N];中國石油報;2005年
4 劉冀人;地震數(shù)據(jù)采集專家唐東磊[N];中國石油報;2001年
5 劉冀人;地震數(shù)據(jù)采集專家鄧志文[N];中國石油報;2001年
6 孟可;東方物探2126隊5個月放8.5萬炮[N];中國石油報;2008年
7 記者 孟可邋通訊員 麻隆;新疆地調(diào)形成獨有采集技術(shù)系列[N];中國石油報;2008年
8 孟可;干一天掙兩天工資[N];中國石油報;2004年
9 張志禮;斗嚴(yán)寒 促生產(chǎn) 保增長[N];中煤地質(zhì)報;2010年
相關(guān)博士學(xué)位論文 前2條
1 汪海山;大型地震數(shù)據(jù)采集記錄系統(tǒng)中數(shù)據(jù)傳輸?shù)年P(guān)鍵技術(shù)研究[D];清華大學(xué);2010年
2 李懷良;復(fù)雜山地多波寬頻帶地震數(shù)據(jù)采集關(guān)鍵技術(shù)研究[D];成都理工大學(xué);2013年
相關(guān)碩士學(xué)位論文 前10條
1 崔衣秀;地震數(shù)據(jù)采集記錄系統(tǒng)中RS編譯碼的原理及實現(xiàn)[D];南京郵電大學(xué);2015年
2 謝靜;分布式地震數(shù)據(jù)采集系統(tǒng)軟件開發(fā)[D];西南科技大學(xué);2016年
3 榮文鉦;分布式地震數(shù)據(jù)采集同步技術(shù)研究[D];西南科技大學(xué);2017年
4 張俊;高分辨、低漂移地震數(shù)據(jù)采集技術(shù)的研究與實驗[D];中國地震局地震預(yù)測研究所;2011年
5 高德芝;基于浮點放大技術(shù)的多通道地震數(shù)據(jù)采集系統(tǒng)的研究[D];吉林大學(xué);2006年
6 李從慶;動態(tài)電源管理技術(shù)在地震數(shù)據(jù)采集系統(tǒng)中的應(yīng)用研究[D];中國地震局地球物理研究所;2011年
7 寧靜;地震數(shù)據(jù)采集儀器系統(tǒng)理論研究[D];大慶石油學(xué)院;2008年
8 鄒鎮(zhèn)宇;應(yīng)用調(diào)制解調(diào)技術(shù)實現(xiàn)低漂移地震數(shù)據(jù)采集的技術(shù)分析與研究[D];中國地震局地震預(yù)測研究所;2011年
9 蔣久明;高分辨率地震數(shù)據(jù)采集中信號處理技術(shù)的研究[D];中國地震局地震預(yù)測研究所;2013年
10 王詩東;ARM平臺下地震數(shù)據(jù)采集軟件系統(tǒng)設(shè)計[D];成都理工大學(xué);2011年
,本文編號:1829142
本文鏈接:http://sikaile.net/shoufeilunwen/xixikjs/1829142.html