基于電化學(xué)原理的血紅蛋白快速檢測方法研究
本文選題:血紅蛋白檢測 + 電化學(xué); 參考:《浙江大學(xué)》2017年碩士論文
【摘要】:血紅蛋白是一種在人體內(nèi)負責(zé)運載氧氣的蛋白質(zhì)。當(dāng)氧含量高的時候,它表現(xiàn)出高氧相容性;氧含量低時,它就釋放出結(jié)合的氧氣。血紅蛋白是表征失血性貧血、遺傳性貧血和一些其他疾病,比如先天性心臟病、阻塞性肺氣腫,的重要指標(biāo)。而目前的血紅蛋白傳感器大多是基于光學(xué)原理制作的,光源不穩(wěn)定,易被污染,易受環(huán)境干擾。本研究的目標(biāo)就是基于絲網(wǎng)印刷碳糊電極和電化學(xué)方法制備一種低成本、一次性的血紅蛋白傳感器,并在此基礎(chǔ)上將檢測過程集成化,免去檢測中額外的血液預(yù)處理過程。本文首先制備了 一種需要溶血步驟的,基于絲網(wǎng)印刷碳糊電極的血紅蛋白傳感器。通過優(yōu)化溶血素的選擇和濃度、溶血振蕩時間、電子傳遞劑用量以及工作參數(shù),檢測了最優(yōu)工作條件下傳感器的靈敏度、線性度、一致性和抗干擾性。實驗結(jié)果表明,傳感器的線性檢測范圍為20g/L-230g/L,靈敏度為0.033μA/(g/L),RSD小于4.59%,且抗干擾性強。在醫(yī)院臨床測試中,和醫(yī)院標(biāo)準(zhǔn)儀器的相關(guān)性達到了 0.9536。本文還進一步研制了集成溶血和檢測兩部分的血紅蛋白傳感器。首先,選擇了適合一步式溶血的溶血素,確定了溶血素的滴涂位置。之后制作了基于微流路和絲網(wǎng)印刷電極的血紅蛋白傳感器。在最優(yōu)條件下,制備的傳感器的線性檢測范圍為70 g/L-230 g/L,其靈敏度為0.041 μA/(g/L),具有較好的一致性。
[Abstract]:Hemoglobin is a protein responsible for carrying oxygen in the body. When oxygen content is high, it shows hyperoxia compatibility; when oxygen content is low, it releases the combined oxygen. Hemoglobin is an important indicator of hemorrhagic anemia, hereditary anemia and some other diseases, such as congenital heart disease, obstructive emphysema. At present, most of the hemoglobin sensors are based on the optical principle. The light source is unstable, easily polluted and easily disturbed by the environment. The aim of this study is to prepare a low cost, disposable hemoglobin sensor based on the screen printing carbon paste electrode and electrochemical method, and on this basis, the detection process is integrated and removed from inspection. A hemoglobin sensor, based on the screen printing carbon paste electrode, was first prepared. The sensitivity and linearity of the sensor were detected by optimizing the selection and concentration of the hemolysin, the time of the hemolysis oscillation, the amount of the electron transfer agent and the working parameters. The experimental results show that the linear detection range of the sensor is 20g/L-230g/L, the sensitivity is 0.033 A/ (g/L), the RSD is less than 4.59%, and the anti-interference ability is strong. In the clinical test of the hospital, the correlation with the standard instrument of the hospital has reached 0.9536. and the blood red egg with the integration of hemolysis and the detection of two parts is further developed. First, the hemolysin suitable for one step hemolysis is selected to determine the position of the hemolysin. Then the hemoglobin sensor based on the microfluidic and screen printing electrodes is produced. Under the optimal condition, the linear detection range of the sensor is 70 g/L-230 g/L, with a sensitivity of 0.041 mu A/ (g/L), which has a better one. Sex.
【學(xué)位授予單位】:浙江大學(xué)
【學(xué)位級別】:碩士
【學(xué)位授予年份】:2017
【分類號】:R446.1;TP212
【參考文獻】
相關(guān)期刊論文 前10條
1 曹俊濤;王輝;陳永紅;劉彥明;;流動注射化學(xué)發(fā)光法靈敏測定人血液和血清中血紅蛋白(英文)[J];光譜學(xué)與光譜分析;2014年01期
2 張亞男;;氰化高鐵血紅蛋白測定法對血紅蛋白測定方法及臨床意義[J];中國現(xiàn)代藥物應(yīng)用;2013年11期
3 王耀玲;王瑞娟;王亞琴;;表面等離子體共振生物傳感器在卵巢腫瘤標(biāo)志物CA125檢測中的應(yīng)用[J];陜西醫(yī)學(xué)雜志;2012年02期
4 張志勇;門劍龍;李剛;林凌;;動態(tài)光譜法用于人體血紅蛋白濃度的無創(chuàng)測量[J];光譜學(xué)與光譜分析;2010年01期
5 劉杰;平建峰;吳堅;項光宏;王健;劉軍;;正弦波伏安法檢測尿酸的研究[J];傳感技術(shù)學(xué)報;2009年08期
6 馬莉萍;毛斌;劉斌;李工農(nóng);韓根亮;劉國漢;;生物傳感器的應(yīng)用現(xiàn)狀與發(fā)展趨勢[J];傳感器與微系統(tǒng);2009年04期
7 鄧元榮;卓儀榮;王玲;;油茶皂苷的體外溶血試驗研究[J];海峽藥學(xué);2008年12期
8 王耀華;;血液中血紅蛋白含量的測定[J];化工時刊;2007年03期
9 林麗;仇佩虹;楊麗珠;曹旭妮;金利通;;納米銀粒子修飾電極法測定血紅蛋白[J];分析化學(xué);2006年01期
10 胡涌剛;龐志濤;;一種高靈敏度測定血紅蛋白的化學(xué)發(fā)光分析方法[J];華中科技大學(xué)學(xué)報(自然科學(xué)版);2006年01期