磁共振GRE電影序列評價恒河猴心功能的重復性及有效性研究
本文關鍵詞: 心臟功能試驗 恒河猴 磁共振成像 出處:《中國臨床醫(yī)學影像雜志》2017年10期 論文類型:期刊論文
【摘要】:目的 :對心臟磁共振梯度回波電影序列(Spoiled gradient echo,GRE)評估恒河猴心功能的有效性與重復性進行評價,為開展恒河猴疾病動物模型磁共振研究提供準確、最優(yōu)的心功能評估策略。方法:正常恒河猴8只,均行超聲心動圖檢查、心臟磁共振GRE電影序列掃描。采用心功能分析軟件(cvi~(42))對GRE電影圖像進行分析獲取左室舒張末容積(EDV)、左室收縮末容積(ESV)、每搏量(SV)、射血分數(shù)(EF)、心輸出量(CO)、舒張期左室質(zhì)量(Myo Mass(Diast))以及收縮期左室質(zhì)量(Myo Mass(Syst))等心功能相關參數(shù)值。進行磁共振掃描的復測實驗,采用組內(nèi)相關系數(shù)及Bland-Altman分析評價GRE各心功能參數(shù)的重復性,以超聲心功能結果為相對的標準效度評價GRE各心功能參數(shù)的有效性,并對超聲和GRE結果進行比較。結果:GRE重復性評價結果顯示,各心功能參數(shù)的組內(nèi)相關系數(shù)(ICC)值均在0.75~0.97之間,且顯著性均小于0.01,重復性評價結果較好,Bland-Altman分析顯示復測實驗中各指標測量的一致性較高;有效性評價結果顯示,除CO外,其余心功能參數(shù)的Pearson相關系數(shù)(r)值在0.80~0.92之間,具有統(tǒng)計學意義;同時發(fā)現(xiàn)GRE獲取的EF、CO以及Myo Mass(Diast)要小于超聲的測定值,差異具有統(tǒng)計學意義。結論:心臟磁共振GRE電影序列評價正常恒河猴心功能的結果具有較好的有效性與重復性,能有效、穩(wěn)定地對恒河猴的心功能予以評價。
[Abstract]:Objective: to evaluate the validity and reproducibility of cardiac magnetic resonance gradient echo sequence (GREE) in evaluating the cardiac function of rhesus monkeys, so as to provide an accurate magnetic resonance study for animal model of rhesus monkey disease. Methods: 8 normal rhesus monkeys were examined by echocardiography. Cardiac magnetic resonance (GRE) film sequence scanning. Using cardiac function analysis software to analyze the GRE image to obtain left ventricular end-diastolic volume (EDV), left ventricular end-systolic volume (LVV), left ventricular end-systolic volume (LVEV), ejection fraction (EF), cardiac output volume (GRE), left ventricular diastolic volume (LV), left ventricular volume (LVEF), ejection fraction (EF), cardiac output volume (GRE) and diastolic left ventricle (LVV). Cardiac function parameters, such as Myo Massa Diasta and left ventricular mass in systolic phase, were measured by magnetic resonance imaging (MRI). The repeatability of cardiac function parameters in GRE was evaluated by intra-group correlation coefficient and Bland-Altman analysis. The validity of cardiac function parameters of GRE was evaluated by the relative standard validity of echocardiographic cardiac function. Results the repeatability of GRE was compared with that of ultrasound. Results the results of repetitive evaluation showed that the intra-group correlation coefficient of each cardiac function parameter was 0.75 ~ 0.97, respectively. The results of repeated Bland-Altman analysis showed that there was a higher consistency of the measurements in the repeated test, and the validity evaluation showed that the Pearson correlation coefficient (r) of the other cardiac function parameters was between 0.80 and 0.92, except for CO. At the same time, it was found that the GRE obtained EFCO and Myo Massi Diasta were smaller than the ultrasonic measurements. Conclusion: the results of cardiac magnetic resonance imaging (GRE) in evaluating the cardiac function of normal rhesus monkeys are effective and reproducible, and can be used to evaluate the cardiac function of rhesus monkeys stably.
【作者單位】: 四川大學華西醫(yī)院放射科;四川普萊美生物科技集團有限公司;圣路易斯華盛頓大學放射科;
【基金】:國家自然科學基金(81520108014,81528009) 重大科技計劃973計劃(2014CB541600) 四川省科技廳國際合作項目(2017HH0045)
【分類號】:R445.2;R540.4
【相似文獻】
相關期刊論文 前9條
1 代解杰,付云生,梁梧生,張春貴;大籠飼養(yǎng)恒河猴B病毒相關抗體的初步調(diào)查[J];中國實驗動物學雜志;1995年04期
2 劉雪松,金伯泉,田方,趙寧,王增祿,曹云新;一種新的恒河猴T淋巴細胞活化抗原PTA1[J];中國實驗動物學報;1997年01期
3 司兆學,靳士英,董紅林,單罷安,梁海清;重組人堿性成纖維細胞生長因子毒性試驗恒河猴舌病理組織學觀察[J];解放軍醫(yī)學高等?茖W校學報;1997年02期
4 潘明新,潘玉先,,何紅兵,楊繼震;恒河猴血管內(nèi)皮細胞原位獲取的實驗研究[J];第一軍醫(yī)大學學報;1996年04期
5 卜曉萍,沈榮,蔣琳,翟雷,沈心亮;戊型肝炎病毒感染的恒河猴急性期糞便中病毒的分離與鑒定[J];中國生物制品學雜志;2002年02期
6 羅天友,呂發(fā)金,熊正愛,李詠梅,方維東,杜永紅,王智彪;正常恒河猴子宮的MRI研究[J];重慶醫(yī)科大學學報;2004年02期
7 姚新宇,李坤成,張進錄,楊慧,徐群淵;MRI對于恒河猴PD模型建立和治療的評價[J];臨床放射學雜志;2002年11期
8 杜永洪,熊正愛,鄒建中,白晉,譚毅,王智彪;超聲、MRI動態(tài)評價恒河猴子宮變化的實驗研究[J];中國醫(yī)學影像學雜志;2005年03期
9 翁中芳,孫文善,劉振國,李培勇,沈鳴華,匡琴芳,朱承謨,陳生弟;β-CIT在正常恒河猴體內(nèi)分布的SPECT顯像研究[J];上海第二醫(yī)科大學學報;2000年06期
相關會議論文 前1條
1 代解杰;高家紅;唐東紅;楊增全;;運用B超技術對恒河猴早期妊娠的診斷[A];中國動物科學研究——中國動物學會第十四屆會員代表大會及中國動物學會65周年年會論文集[C];1999年
本文編號:1526558
本文鏈接:http://sikaile.net/linchuangyixuelunwen/1526558.html